Youngsub Eom, Su-Yeon Kang, Jong Suk Song, Yong Yeon Kim, Hyo Myung Kim
发表日期
2015/2/1
期刊
Canadian Journal of Ophthalmology
卷号
50
期号
1
页码范围
26-32
出版商
Elsevier
简介
Objective
To evaluate the effects of effective lens position (ELP) on the corneal plane effective cylinder power of toric intraocular lenses (IOLs).
Design
Retrospective cross-sectional study.
Participants
Ninety-four eyes from 78 patients who underwent uncomplicated phacoemulsification with implantation of an AcrySof toric IOL (1.50- to 3.00-D cylinder).
Methods
The amount of corneal plane effective cylinder power of toric IOLs given by the manufacturer (target-induced astigmatism vector [TIA]) was compared with the postoperatively achieved cylindrical correction (surgically induced astigmatism vector [SIA]). The theoretical corneal plane cylinder power of toric IOLs was calculated according to ELP and corneal power using a refractive vergence formula.
Results
The TIA (1.59 ± 0.43 D) was significantly smaller than the SIA (1.78 ± 0.65 D; p < 0.001). The difference between the magnitudes of SIA and TIA demonstrated a …