作者
Shuo Du, Wenyan Liu, Yang Yao, Guozhe Sun, Ying He, Jordi Alastruey, Lisheng Xu, Yudong Yao, Wei Qian
发表日期
2022/11/30
期刊
Measurement
卷号
204
页码范围
112111
出版商
Elsevier
简介
Existing studies cannot estimate the high-frequency components of the aortic pressure waveform (APW) practically and reliably. To solve this problem, a two-level adaptive transfer function (ATF) strategy was proposed. Two ATFs were derived from raw and normalized brachial and aortic pressure waveforms. The APW was reconstructed with the amplitude and pulsatility information from the two ATFs. Experimental results showed that our method achieved lower errors for total waveform, diastolic blood pressure, the pressures at the start-systolic and dicrotic-notch points, and three high-frequency-dependent indices including the pressure at inflection point, augmentation index and the time interval from foot to inflection points (3.11 versus 4.24 mmHg, 1.74 versus 1.94 mmHg, 2.56 versus 2.75 mmHg, 6.94 versus 7.47 mmHg, 3.35 versus 3.80 mmHg, 9.56 versus 10.48 % and 24.64 versus 27.73 ms, respectively …
引用总数
学术搜索中的文章