作者
P Tsiamas, E Sajo, F Cifter, K Theodorou, C Kappas, M Makrigiorgos, K Marcus, P Zygmanski
发表日期
2014/2/1
期刊
Physica Medica
卷号
30
期号
1
页码范围
47-56
出版商
Elsevier
简介
The aim of this study is twofold: (a) determination of the spectral differences for flattening-filter-free (FFF) versus standard (STD) linac under various clinical conditions, (b) based on an extensive list of clinically important beam configurations, identification of clinical scenarios that lead to higher macroscopic dose perturbations due to the presence of high-Z material. The focus is on dose enhancement due to contrast agents including high-Z elements such as gold or gadolinium.
EGSnrc was used to simulate clinical beams under various irradiation conditions: open/IMRT/spit-IMRT fields, in/out-off-field areas, different depths and field sizes. Spectra were calculated and analyzed for about 80 beams and for a total of 480 regions. Quantitative differential effects in beam quality were characterized using energy-dependent and cumulative dose perturbation metrics.
Analysis of the spectral database showed that even though …
引用总数
2013201420152016201720182019202020212022202313426326343
学术搜索中的文章