作者
Erkan Yildirim, Ismail Kirbas, Ali Harman, Umut Ozyer, H Gurkan Tore, Cuneyt Aytekin, Fatih Boyvat
发表日期
2009/4/1
期刊
European journal of radiology
卷号
70
期号
1
页码范围
57-60
出版商
Elsevier
简介
PURPOSE
We present our 7-year experience with coaxial computed tomography (CT)-guided cutting needle lung biopsy and evaluate the factors affecting risk of complications.
MATERIAL AND METHOD
Between June 2000 and March 2007, we performed 225 CT-guided coaxial lung biopsies in 213 consecutive patients (161 men, 52 women). Lesion size, lesion depth, lesion location, needle-pleural angle, presence of pleural effusion, patient's position, and complications secondary to biopsy procedure (pneumothorax and bleeding) were noted. Pneumothorax was graded as mild, moderate, and severe. Bleeding complications were graded as mild, moderate, and severe.
RESULTS
Two hundred twenty-five biopsy procedures were performed in 213 patients. The mean diameter of the lung lesion was 41.3±20.1mm. The mean distance from the peripheral margin of the lesion to the pleura was 17.3±19.2mm. After …
引用总数
200920102011201220132014201520162017201820192020202120222023202428138887165169511782