Background
Strategies to prevent bacterial fallout and reduce particle count in the operating room (OR) are key components of preventing periprosthetic joint infection. Although OR traffic control is an important factor, a quantitative study has not been performed to investigate the influence of personnel and door opening on OR air quality. This simulated study aimed to examine the influence of these 2 factors on particle density in OR with and without the laminar air flow (LAF).
Methods
Both experiments took place within an empty OR of an arthroplasty unit equipped with an LAF system. First, the number of particles in the air was counted using a particle counting apparatus while 9 persons entered the room, one every 15 minutes. Second, the door was opened and closed starting with zero door openings per minute and increasing to 4 in 15-minute increments. Both experiments were performed once with the LAF turned …