关注
Benoit Dawant
Benoit Dawant
在 vanderbilt.edu 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Morphometric analysis of white matter lesions in MR images: method and validation
AP Zijdenbos, BM Dawant, RA Margolin, AC Palmer
IEEE transactions on medical imaging 13 (4), 716-724, 1994
15381994
Comparison and evaluation of retrospective intermodality brain image registration techniques
J West, JM Fitzpatrick, MY Wang, BM Dawant, CR Maurer Jr, RM Kessler, ...
Journal of computer assisted tomography 21 (4), 554-568, 1997
13041997
Comparison and evaluation of methods for liver segmentation from CT datasets
T Heimann, B Van Ginneken, MA Styner, Y Arzhaeva, V Aurich, C Bauer, ...
IEEE transactions on medical imaging 28 (8), 1251-1265, 2009
11432009
The adaptive bases algorithm for intensity-based nonrigid image registration
GK Rohde, A Aldroubi, BM Dawant
IEEE transactions on medical imaging 22 (11), 1470-1479, 2003
5372003
Correction of intensity variations in MR images for computer-aided tissue classification
BM Dawant, AP Zijdenbos, RA Margolin
IEEE transactions on medical imaging 12 (4), 770-781, 1993
4201993
Neural-network-based segmentation of multi-modal medical images: a comparative and prospective study
M Ozkan, BM Dawant, RJ Maciunas
IEEE transactions on Medical Imaging 12 (3), 534-544, 1993
3221993
Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes
GB Wanna, JH Noble, ML Carlson, RH Gifford, MS Dietrich, DS Haynes, ...
The Laryngoscope 124 (S6), S1-S7, 2014
3212014
Brain segmentation and white matter lesion detection in MR images.
AP Zijdenbos, BM Dawant
Critical reviews in biomedical engineering 22 (5-6), 401-465, 1994
3121994
Automatic 3-D segmentation of internal structures of the head in MR images using a combination of similarity and free-form transformations. I. Methodology and validation on …
BM Dawant, SL Hartmann, JP Thirion, F Maes, D Vandermeulen, ...
IEEE transactions on medical imaging 18 (10), 909-916, 1999
3091999
Registration of 3-D images using weighted geometrical features
CR Maurer, GB Aboutanos, BM Dawant, RJ Maciunas, JM Fitzpatrick
IEEE transactions on medical imaging 15 (6), 836-849, 1996
2591996
Evaluation of segmentation methods on head and neck CT: auto‐segmentation challenge 2015
PF Raudaschl, P Zaffino, GC Sharp, MF Spadea, A Chen, BM Dawant, ...
Medical physics 44 (5), 2020-2036, 2017
2342017
Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation
BP O’Connell, A Cakir, JB Hunter, DO Francis, JH Noble, RF Labadie, ...
Otology & neurotology: official publication of the American Otological …, 2016
2102016
Retrospective intermodality registration techniques for images of the head: surface-based versus volume-based
J West, JM Fitzpatrick, MY Wang, BM Dawant, CR Maurer, RM Kessler, ...
IEEE Transactions on Medical Imaging 18 (2), 144-150, 1999
2071999
Three-dimensional visualization of protein expression in mouse brain structures using imaging mass spectrometry
AC Crecelius, DS Cornett, RM Caprioli, B Williams, BM Dawant, ...
Journal of the American Society for Mass Spectrometry 16 (7), 1093-1099, 2005
1972005
Minimally invasive image‐guided cochlear implantation surgery: first report of clinical implementation
RF Labadie, R Balachandran, JH Noble, GS Blachon, JE Mitchell, ...
The Laryngoscope 124 (8), 1915-1922, 2014
1932014
Electrophysiological atlas and applications of same
B Dawant, PF D'Haese, P Konrad, C Kao, E Cetinkaya
US Patent App. 10/883,233, 2005
1932005
Automatic segmentation of intracochlear anatomy in conventional CT
JH Noble, RF Labadie, O Majdani, BM Dawant
IEEE Transactions on Biomedical Engineering 58 (9), 2625-2632, 2011
1902011
Apparatus and methods of optimal placement of deep brain stimulator
BM Dawant, PE Konrad, JM Fitzpatrick
US Patent 7,167,760, 2007
1832007
Integrating spatially resolved three-dimensional MALDI IMS with in vivo magnetic resonance imaging
TK Sinha, S Khatib-Shahidi, TE Yankeelov, K Mapara, M Ehtesham, ...
Nature methods 5 (1), 57-59, 2008
1762008
System and methods of deep brain stimulation for post-operation patients
BM Dawant, PD D'haese, PE Konrad
US Patent 7,957,808, 2011
1712011
系统目前无法执行此操作,请稍后再试。
文章 1–20