A blood-mimicking fluid for particle image velocimetry with silicone vascular models MY Yousif, DW Holdsworth, TL Poepping Experiments in fluids 50, 769-774, 2011 | 151 | 2011 |
Flow patterns at the stenosed carotid bifurcation: effect of concentric versus eccentric stenosis DA Steinman, TL Poepping, M Tambasco, RN Rankin, DW Holdsworth Annals of biomedical engineering 28, 415-423, 2000 | 142 | 2000 |
An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation TL Poepping, N Nikolov, N Rankin, M Lee, DW Holdsworth Ultrasound in medicine & biology 28 (4), 495-506, 2002 | 109 | 2002 |
A thin-walled carotid vessel phantom for Doppler ultrasound flow studies TL Poepping, HN Nikolov, ML Thorne, DW Holdsworth Ultrasound in medicine & biology 30 (8), 1067-1078, 2004 | 97 | 2004 |
Transitional flow analysis in the carotid artery bifurcation by proper orthogonal decomposition and particle image velocimetry S Kefayati, TL Poepping Medical engineering & physics 35 (7), 898-909, 2013 | 74 | 2013 |
Flow patterns in carotid bifurcation models using pulsed Doppler ultrasound: effect of concentric vs. eccentric stenosis on turbulence and recirculation TL Poepping, RN Rankin, DW Holdsworth Ultrasound in medicine & biology 36 (7), 1125-1134, 2010 | 70 | 2010 |
Design and characterisation of a wall motion phantom J Dineley, S Meagher, TL Poepping, WN McDicken, PR Hoskins Ultrasound in medicine & biology 32 (9), 1349-1357, 2006 | 68 | 2006 |
Turbulence intensity measurements using particle image velocimetry in diseased carotid artery models: Effect of stenosis severity, plaque eccentricity, and ulceration S Kefayati, DW Holdsworth, TL Poepping Journal of biomechanics 47 (1), 253-263, 2014 | 61 | 2014 |
Deriving a blood-mimicking fluid for particle image velocimetry in Sylgard-184 vascular models MY Yousif, DW Holdsworth, TL Poepping 2009 Annual International Conference of the IEEE Engineering in Medicine and …, 2009 | 60 | 2009 |
Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: experimental validation with Doppler ultrasound S Meagher, TL Poepping, KV Ramnarine, RA Black, PR Hoskins Ultrasound in medicine & biology 33 (2), 303-310, 2007 | 57 | 2007 |
In vitro shear stress measurements using particle image velocimetry in a family of carotid artery models: effect of stenosis severity, plaque eccentricity, and ulceration S Kefayati, JS Milner, DW Holdsworth, TL Poepping PloS one 9 (7), e98209, 2014 | 48 | 2014 |
Study of the effect of stenosis severity and non-Newtonian viscosity on multidirectional wall shear stress and flow disturbances in the carotid artery using particle image … AL DiCarlo, DW Holdsworth, TL Poepping Medical engineering & physics 65, 8-23, 2019 | 40 | 2019 |
Origins of the edge shadowing artefact in medical ultrasound imaging R Steel, TL Poepping, RS Thompson, C Macaskill Ultrasound in medicine & biology 30 (9), 1153-1162, 2004 | 37 | 2004 |
Membrane Lipid-KIR2.x Channel Interactions Enable Hemodynamic Sensing in Cerebral Arteries M Sancho, S Fabris, BO Hald, SE Brett, SL Sandow, TL Poepping, ... Arteriosclerosis, Thrombosis, and Vascular Biology 39 (6), 1072-1087, 2019 | 32 | 2019 |
Clinical Doppler ultrasound for the assessment of plaque ulceration in the stenosed carotid bifurcation by detection of distal turbulence intensity: a matched model study EY Wong, HN Nikolov, ML Thorne, TL Poepping, RN Rankin, ... European radiology 19, 2739-2749, 2009 | 32 | 2009 |
Real-time numerical simulation of Doppler ultrasound in the presence of nonaxial flow M Khoshniat, ML Thorne, TL Poepping, S Hirji, DW Holdsworth, ... Ultrasound in medicine & biology 31 (4), 519-528, 2005 | 31 | 2005 |
A model of blood supply to the brain via the carotid arteries: Effects of obstructive vs. sclerotic changes O Onaizah, TL Poepping, M Zamir Medical engineering & physics 49, 121-130, 2017 | 29 | 2017 |
Use of an ultrasound blood-mimicking fluid for Doppler investigations of turbulence in vitro ML Thorne, TL Poepping, RN Rankin, DA Steinman, DW Holdsworth Ultrasound in medicine & biology 34 (7), 1163-1173, 2008 | 29 | 2008 |
Characterization of various tissue mimicking materials for medical ultrasound imaging A Thouvenot, T Poepping, TM Peters, ECS Chen Medical Imaging 2016: Physics of Medical Imaging 9783, 1436-1444, 2016 | 26 | 2016 |
Doppler ultrasound compatible plastic material for use in rigid flow models EY Wong, ML Thorne, HN Nikolov, TL Poepping, DW Holdsworth Ultrasound in medicine & biology 34 (11), 1846-1856, 2008 | 22 | 2008 |