关注
Christian Ghiaus
Christian Ghiaus
INSA Lyon, France
在 insa-lyon.fr 的电子邮件经过验证
标题
引用次数
引用次数
年份
Optimal temperature control of intermittently heated buildings using Model Predictive Control: Part I–Building modeling
I Hazyuk, C Ghiaus, D Penhouet
Building and Environment 51, 379-387, 2012
2952012
Natural ventilation in the urban environment
F Allard, C Ghiaus
Assessement and Design, 2005
224*2005
Optimal temperature control of intermittently heated buildings using Model Predictive Control: Part II–Control algorithm
I Hazyuk, C Ghiaus, D Penhouet
Building and Environment 51, 388-394, 2012
1832012
Urban environment influence on natural ventilation potential
C Ghiaus, F Allard, M Santamouris, C Georgakis, F Nicol
Building and environment 41 (4), 395-406, 2006
1722006
Fast method to predict building heating demand based on the design of experiments
I Jaffal, C Inard, C Ghiaus
Energy and buildings 41 (6), 669-677, 2009
1392009
Experimental estimation of building energy performance by robust regression
C Ghiaus
Energy and buildings 38 (6), 582-587, 2006
1372006
Calculation of optimal thermal load of intermittently heated buildings
C Ghiaus, I Hazyuk
Energy and Buildings 42 (8), 1248-1258, 2010
1062010
Fast simulation of temperature distribution in air conditioned rooms by using proper orthogonal decomposition
A Sempey, C Inard, C Ghiaus, C Allery
Building and Environment 44 (2), 280-289, 2009
992009
Potential for free-cooling by ventilation
C Ghiaus, F Allard
Solar Energy 80 (4), 402-413, 2006
912006
Modeling of water spray evaporation: Application to passive cooling of buildings
R Belarbi, C Ghiaus, F Allard
Solar energy 80 (12), 1540-1552, 2006
902006
Grey-box identification of air-handling unit elements
C Ghiaus, A Chicinas, C Inard
Control Engineering Practice 15 (4), 421-433, 2007
842007
Fuzzy model and control of a fan-coil
C Ghiaus
Energy and Buildings 33 (6), 545-551, 2001
772001
Fault diagnosis of air conditioning systems based on qualitative bond graph
C Ghiaus
Energy and buildings 30 (3), 221-232, 1999
691999
Causality issue in the heat balance method for calculating the design heating and cooling load
C Ghiaus
Energy 50, 292-301, 2013
652013
Model Predictive Control of thermal comfort as a benchmark for controller performance
I Hazyuk, C Ghiaus, D Penhouet
Automation in Construction 43, 98-109, 2014
622014
Free-running building temperature and HVAC climatic suitability
C Ghiaus
Energy and Buildings 35 (4), 405-411, 2003
512003
Free-running temperature and potential for free cooling by ventilation: A case study
C Inard, J Pfafferott, C Ghiaus
Energy and Buildings 43 (10), 2705-2711, 2011
392011
Equivalence between the load curve and the free-running temperature in energy estimating methods
C Ghiaus
Energy and Buildings 38 (5), 429-435, 2006
372006
Physical parameters identification of walls using ARX models obtained by deduction
I Naveros, C Ghiaus, DP Ruíz, S Castaño
Energy and Buildings 108, 317-329, 2015
332015
An efficient Bayesian experimental calibration of dynamic thermal models
L Raillon, C Ghiaus
Energy 152, 818-833, 2018
322018
系统目前无法执行此操作,请稍后再试。
文章 1–20