Cardiorespiratory, metabolic, and biomechanical responses during functional electrical stimulation leg exercise: health and fitness benefits GM Davis, NA Hamzaid, C Fornusek Artificial organs 32 (8), 625-629, 2008 | 147 | 2008 |
Mechanomyography and muscle function assessment: A review of current state and prospects MO Ibitoye, NA Hamzaid, JM Zuniga, AKA Wahab Clinical Biomechanics 29 (6), 691-704, 2014 | 140 | 2014 |
Strategies for rapid muscle fatigue reduction during FES exercise in individuals with spinal cord injury: a systematic review MO Ibitoye, NA Hamzaid, N Hasnan, AK Abdul Wahab, GM Davis PloS one 11 (2), e0149024, 2016 | 108 | 2016 |
Development of a micro-gripper using piezoelectric bimorphs AM El-Sayed, A Abo-Ismail, MT El-Melegy, NA Hamzaid, NA Abu Osman Sensors 13 (5), 5826-5840, 2013 | 66 | 2013 |
Mechanomyographic parameter extraction methods: an appraisal for clinical applications MO Ibitoye, NA Hamzaid, JM Zuniga, N Hasnan, AKA Wahab Sensors 14 (12), 22940-22970, 2014 | 64 | 2014 |
The effectiveness of FES-evoked EMG potentials to assess muscle force and fatigue in individuals with spinal cord injury MO Ibitoye, EH Estigoni, NA Hamzaid, AKA Wahab, GM Davis Sensors 14 (7), 12598-12622, 2014 | 54 | 2014 |
Development of computer play pedagogy intervention for children with low conceptual understanding in basic mathematics operation using the dyscalculia feature approach NE Mohd Syah, NA Hamzaid, BP Murphy, E Lim Interactive Learning Environments 24 (7), 1477-1496, 2016 | 53 | 2016 |
Health and fitness benefits of functional electrical stimulation-evoked leg exercise for spinal cord–Injured individuals: A position review NA Hamzaid, G Davis Topics in Spinal Cord Injury Rehabilitation 14 (4), 88-121, 2009 | 49 | 2009 |
Technology efficacy in active prosthetic knees for transfemoral amputees: A quantitative evaluation AM El-Sayed, NA Hamzaid, NA Abu Osman The Scientific World Journal 2014 (1), 297431, 2014 | 47 | 2014 |
Estimation of electrically-evoked knee torque from mechanomyography using support vector regression MO Ibitoye, NA Hamzaid, AK Abdul Wahab, N Hasnan, SO Olatunji, ... Sensors 16 (7), 1115, 2016 | 32 | 2016 |
In-socket sensory system for transfemoral amputees using piezoelectric sensors: An efficacy study F Jasni, NA Hamzaid, AG Abd Muthalif, Z Zakaria, HN Shasmin, SC Ng IEEE/ASME Transactions on Mechatronics 21 (5), 2466-2476, 2016 | 32 | 2016 |
Piezoelectric bimorphs' characteristics as in-socket sensors for transfemoral amputees AM El-Sayed, NA Hamzaid, NAA Osman Sensors 14 (12), 23724-23741, 2014 | 26 | 2014 |
Evoked EMG versus Muscle Torque during Fatiguing Functional Electrical Stimulation-Evoked Muscle Contractions and Short-Term Recovery in Individuals with … EH Estigoni, C Fornusek, NA Hamzaid, N Hasnan, RM Smith, GM Davis Sensors 14 (12), 22907-22920, 2014 | 26 | 2014 |
Isokinetic cycling and elliptical stepping: a kinematic and muscle activation analysis NA Hamzaid, RM Smith, GM Davis Clin Res Foot Ankle 1, 117, 2013 | 22 | 2013 |
Mechanomyography and torque during FES-evoked muscle contractions to fatigue in individuals with spinal cord injury NZ Mohamad, NA Hamzaid, GM Davis, AK Abdul Wahab, N Hasnan Sensors 17 (7), 1627, 2017 | 21 | 2017 |
Functional electrical stimulation in clinical applications: Fitness and cardiovascular health GM Davis, NA Hamzaid, N Hasnan 2014 IEEE 19th International Functional Electrical Stimulation Society …, 2014 | 21 | 2014 |
Mechanomyography-based muscle fatigue detection during electrically elicited cycling in patients with spinal cord injury J Naeem, NA Hamzaid, MA Islam, AW Azman, M Bijak Medical & biological engineering & computing 57, 1199-1211, 2019 | 20 | 2019 |
Functional electrical stimulation elliptical stepping versus cycling in spinal cord-injured individuals NA Hamzaid, KR Pithon, RM Smith, GM Davis Clinical Biomechanics 27 (7), 731-737, 2012 | 20 | 2012 |
Detection of Prosthetic Knee Movement Phases via In‐Socket Sensors: A Feasibility Study AM El-Sayed, NA Hamzaid, KYS Tan, NA Abu Osman The Scientific World Journal 2015 (1), 923286, 2015 | 18 | 2015 |
Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury MO Ibitoye, NA Hamzaid, N Hasnan, AKA Wahab, MA Islam, VSP Kean, ... Medical Engineering & Physics 38 (8), 767-775, 2016 | 16 | 2016 |