关注
Bassey Bassey
标题
引用次数
引用次数
年份
Spectral K-edge subtraction imaging
Y Zhu, N Samadi, M Martinson, B Bassey, Z Wei, G Belev, D Chapman
Physics in Medicine & Biology 59 (10), 2485, 2014
422014
Phase-preserving beam expander for biomedical X-ray imaging
M Martinson, N Samadi, B Bassey, A Gomez, D Chapman
Journal of Synchrotron Radiation 22 (3), 801-806, 2015
292015
Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging
M Martinson, N Samadi, G Belev, B Bassey, R Lewis, G Aulakh, ...
Journal of Synchrotron Radiation 21 (3), 479-483, 2014
212014
Wide field imaging energy dispersive X-ray absorption spectroscopy
P Qi, N Samadi, M Martinson, O Ponomarenko, B Bassey, A Gomez, ...
Scientific Reports 9 (1), 17734, 2019
202019
Multiple energy synchrotron biomedical imaging system
B Bassey, M Martinson, N Samadi, G Belev, C Karanfil, P Qi, D Chapman
Physics in Medicine & Biology 61 (23), 8180, 2016
172016
A phase-space beam position monitor for synchrotron radiation
N Samadi, B Bassey, M Martinson, G Belev, L Dallin, M de Jong, ...
Journal of Synchrotron Radiation 22 (4), 946-955, 2015
122015
Dynamic optimal control model for periodic multiple chemotherapy (PMC) treatment of dual HIV-pathogen infections
BE Bassey
J Anal Pharm Res 6 (3), 00176, 2017
72017
An energy dispersive bent Laue monochromator for K-edge subtraction imaging
N Samadi, M Martinson, B Bassey, A Gomez, G Belev, D Chapman
AIP Conference Proceedings 1741 (1), 2016
72016
Multiple energy synchrotron biomedical imaging system-preliminary results
B Bassey, M Mercedes, N Samadi, G Belev, C Karanfil, D Chapman
World Congress on Medical Physics and Biomedical Engineering, June 7-12 …, 2015
42015
Crossover artifact in X-ray focusing imaging systems: K-edge subtraction imaging
B Bassey, N Samadi, A Panahifar, DML Cooper, D Chapman
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2018
22018
Quantum optimal control dynamics for delay intracellular and multiple chemotherapy treatment (MCT) of dual delayed HIV-pathogen infections
BE Bassey
International Journal of Scientific and Innovative Mathematical Research 5 …, 2017
22017
Synchrotron radiation shielding design for the Brockhouse sector at the Canadian light source
B Bassey, B Moreno, A Gomez, AS Ahmed, D Ullrich, D Chapman
Radiation Physics and Chemistry 98, 109-112, 2014
22014
DEVELOPMENT OF A MULTIPLE ENERGY SYNCHROTRON BIOMEDICAL IMAGING SYSTEM
BE Bassey
University of Saskatchewan, 2017
12017
Small and Ultra-Small Angle X-Ray Scattering Contrast Obtained With a Synchrotron-Based Shack–Hartmann Imaging System
S Wiebe, N Samadi, G Belev, M Martinson, B Bassey, D Chapman
IEEE Transactions on Nuclear Science 62 (5), 2031-2035, 2015
12015
Supplemental shielding of BMIT SOE-1 at the Canadian Light Source
B Bassey, A Abueidda, G Cubbon, D Street, AS Ahmed, TW Wysokinski, ...
Radiation Physics and Chemistry 100, 8-12, 2014
12014
X-ray optics development for biomedical imaging applications at the Canadian Light Source
D Chapman, N Samadi, M Martnson, B Bassey, S Boire, G Belev, ...
Physics in Canada 70 (1), 19-23, 2014
12014
Synchrotron radiation shielding design and ICRP radiological protection quantities
B Bassey, B Moreno, D Chapman
Journal of Radiological Protection 35 (2), 383, 2015
2015
Poster—Thur Eve—56: Verification of buildup region dose calculation of a treatment planning system
B Bassey, N Sidhu
Medical Physics 39 (7Part3), 4635-4635, 2012
2012
Experimental verification of buildup region dose calculation for a commercial treatment planning system
BE Bassey
University of Saskatchewan, 2011
2011
Effective quality factor for neutrons
B Bassey, B Moreno, D Chapman, R Leggett, C O’Connell, RW Leggett
系统目前无法执行此操作,请稍后再试。
文章 1–20