关注
Andrzej Młyniec
Andrzej Młyniec
Space Technology Centre at AGH University of Krakow
在 agh.edu.pl 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
The twisted structure of the Achilles tendon unraveled: A detailed quantitative and qualitative anatomical investigation
PA Pękala, BM Henry, A Ochała, P Kopacz, G Tatoń, A Młyniec, ...
Scandinavian journal of medicine & science in sports 27 (12), 1705-1715, 2017
1202017
Experimental and numerical study on the effect of humidity-temperature cycling on structural multi-material adhesive joints
J Korta, A Mlyniec, T Uhl
Composites Part B: Engineering 79, 621-630, 2015
892015
The influence of the laminate thickness, stacking sequence and thermal aging on the static and dynamic behavior of carbon/epoxy composites
A Mlyniec, J Korta, R Kudelski, T Uhl
Composite Structures 118, 208-216, 2014
622014
A review and perspectives on predicting the performance and durability of electrical contacts in automotive applications
KT Kloch, P Kozak, A Mlyniec
Engineering Failure Analysis 121, 105143, 2021
302021
The differences in viscoelastic properties of subtendons result from the anatomical tripartite structure of human Achilles tendon-ex vivo experimental study and modeling
M Ekiert, KA Tomaszewski, A Mlyniec
Acta biomaterialia 125, 138-153, 2021
262021
Phenomenological and chemomechanical modeling of the thermomechanical stability of liquid silicone rubbers
A Mlyniec, A Morawska-Chochol, K Kloch, T Uhl
Polymer degradation and stability 99, 290-297, 2014
262014
Modelling and testing of ageing of short fibre reinforced polymer composites
A Młyniec, T Uhl
Proceedings of the Institution of Mechanical Engineers, Part C: Journal of …, 2012
242012
Structurally based constitutive model of epoxy adhesives incorporating the influence of post-curing and thermolysis
A Mlyniec, J Korta, T Uhl
Composites Part B: Engineering 86, 160-167, 2016
232016
Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons
R Obuchowicz, M Ekiert, P Kohut, K Holak, L Ambrozinski, ...
Journal of the Mechanical Behavior of Biomedical Materials 97, 238-246, 2019
222019
Molecular-based nonlinear viscoelastic chemomechanical model incorporating thermal denaturation kinetics of collagen fibrous biomaterials
A Mlyniec, KA Tomaszewski, EM Spiesz, T Uhl
Polymer Degradation and Stability 119, 87-95, 2015
202015
Viscoelasticity and failure of collagen nanofibrils: 3D coarse-grained simulation studies
A Mlyniec, L Mazur, KA Tomaszewski, T Uhl
Soft Materials 13 (1), 47-58, 2015
192015
The influence of degradation on the viscosity and molecular mass of poly (lactide acid) biopolymer
M Ekiert, A Mlyniec, T Uhl
Diagnostyka 16 (4), 63--70, 2015
182015
The dispersion of viscoelastic properties of fascicle bundles within the tendon results from the presence of interfascicular matrix and flow of body fluids
A Mlyniec, S Dabrowska, M Heljak, WP Weglarz, K Wojcik, ...
Materials Science and Engineering: C 130, 112435, 2021
172021
Influence of density and environmental factors on decomposition kinetics of amorphous polylactide–Reactive molecular dynamics studies
A Mlyniec, M Ekiert, A Morawska-Chochol, T Uhl
Journal of Molecular Graphics and Modelling 67, 54-61, 2016
152016
Adaptive de-icing system–numerical simulations and laboratory experimental validation
A Młyniec, Ł Ambroziński, P Paćko, J Bednarz, W Staszewski, T Uhl
International Journal of Applied Electromagnetics and Mechanics, 2014
142014
The effect of multiple freeze-thaw cycles on the viscoelastic properties and microstructure of bovine superficial digital flexor tendon
M Ekiert, J Karbowniczek, U Stachewicz, A Mlyniec
Journal of the Mechanical Behavior of Biomedical Materials 120, 104582, 2021
122021
Finite element analysis of adhesive bonds using the cohesive zone modeling method
J Korta, A Młyniec, P Zdziebko, T Uhl
Mechanics and Control 33 (2), 51--57, 2014
82014
The use of digital image correlation in the study of Achilles tendon strain field
K Holak, P Kohut, A Młyniec, M Ekiert, K Tomaszewski, T Uhl
Mechanics and Control 34 (1), 19-26, 2015
72015
A 3D scanning system for inverse analysis of moist biological samples: Design and validation using tendon fascicle bundles
S Dabrowska, M Ekiert, K Wojcik, M Kalemba, A Mlyniec
Sensors 20 (14), 3847, 2020
62020
An overview and review of testing methods for the verification and validation of ADAS, active safety systems, and autonomous driving
M Pietruch, A Młyniec, A Wetula
Mining–Informatics, Automation and Electrical Engineering 58 (1), 2020
62020
系统目前无法执行此操作,请稍后再试。
文章 1–20