Challenges of data center thermal management
RR Schmidt, EE Cruz, M Iyengar
IBM Journal of Research and Development 49 (4.5), 709-723, 2005
2922005
Design of optimum plate-fin natural convective heat sinks
A Bar-Cohen, M Iyengar, AD Kraus
J. Electron. Packag. 125 (2), 208-216, 2003
2292003
Apparatus and method for facilitating cooling of an electronics system
MK Iyengar, V Kamath, JA Matteson, RR Schmidt, ME Steinke
US Patent 7,660,109, 2010
1892010
Hybrid air and liquid coolant conditioning unit for facilitating cooling of one or more electronics racks of a data center
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 7,963,119, 2011
1832011
Cooling apparatus and method for an electronics module employing an integrated heat exchange assembly
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RR Schmidt, ...
US Patent 7,184,269, 2007
1732007
Cooled electronic module with pump-enhanced, dielectric fluid immersion-cooling
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 8,014,150, 2011
1632011
Cooling system and method minimizing power consumption in cooling liquid-cooled electronics racks
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 8,583,290, 2013
1492013
Method of facilitating cooling of electronics racks of a data center employing multiple cooling stations
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RR Schmidt, ...
US Patent 7,477,514, 2009
1482009
Energy efficient apparatus and method for cooling an electronics rack
RC Chu, MK Iyengar, V Kamath, RR Schmidt
US Patent 7,791,882, 2010
1472010
Rack with integrated rear-door heat exchanger
A Claassen, EA Eckberg, DJ Hansen, V Kamath, MK Iyengar, ...
US Patent 7,660,116, 2010
1462010
Server liquid cooling with chiller-less data center design to enable significant energy savings
M Iyengar, M David, P Parida, V Kamath, B Kochuparambil, D Graybill, ...
2012 28th annual IEEE semiconductor thermal measurement and management …, 2012
1432012
Liquid-cooled electronics rack with immersion-cooled electronic subsystems
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 8,184,436, 2012
1392012
Cooling system and method employing a closed loop coolant path and micro-scaled cooling structure within an electronics subsystem of an electronics rack
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RR Schmidt, ...
US Patent 6,973,801, 2005
1332005
Method and air-cooling unit with dynamic airflow and heat removal adjustability
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RR Schmidt, ...
US Patent 7,630,795, 2009
1292009
Cooling system and method employing auxiliary thermal capacitor unit for facilitating continuous operation of an electronics rack
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RR Schmidt, ...
US Patent 7,086,247, 2006
1282006
Comparative analysis of different data center airflow management configurations
S Shrivastava, B Sammakia, R Schmidt, M Iyengar
International Electronic Packaging Technical Conference and Exhibition 42002 …, 2005
1242005
Liquid cooling apparatus and method for cooling blades of an electronic system chassis
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 7,944,694, 2011
1232011
Open flow cold plate for liquid cooled electronic packages
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 7,916,483, 2011
1172011
Thermally conductive composite interface, cooled electronic assemblies employing the same, and methods of fabrication thereof
LA Campbell, RC Chu, MJ Ellsworth Jr, KE Fogel, MK Iyengar, ...
US Patent 7,967,062, 2011
1162011
Apparatus and method for immersion-cooling of an electronic system utilizing coolant jet impingement and coolant wash flow
LA Campbell, RC Chu, MJ Ellsworth Jr, MK Iyengar, RE Simons
US Patent 7,885,070, 2011
1142011