关注
Alessandro Olivo
Alessandro Olivo
Professor of Applied Physics, University College London
在 ucl.ac.uk 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources
A Olivo, R Speller
Applied Physics Letters 91 (7), 2007
3952007
Mammography with synchrotron radiation: phase-detection techniques
F Arfelli, V Bonvicini, A Bravin, G Cantatore, E Castelli, LD Palma, ...
Radiology 215 (1), 286-293, 2000
3762000
Low-dose phase contrast x-ray medical imaging
F Arfelli, M Assante, V Bonvicini, A Bravin, G Cantatore, E Castelli, ...
Physics in Medicine & Biology 43 (10), 2845, 1998
3281998
An Innovative Digital Imaging Set-up Allowing a Low-Dose Approach to Phase Contrast Applications in the Medical Field
C Olivo, Arfelli, Cantatore, Longo, Menk, Pani, Prest, Poropat, Rigon ...
Medical Physics 28, 1610-19, 2001
2402001
Hard X-ray dark-field imaging with incoherent sample illumination
M Endrizzi, PC Diemoz, TP Millard, J Louise Jones, RD Speller, ...
Applied Physics Letters 104 (2), 2014
1792014
Phase and absorption retrieval using incoherent X-ray sources
PRT Munro, K Ignatyev, RD Speller, A Olivo
Proceedings of the National Academy of Sciences 109 (35), 13922-13927, 2012
1512012
Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA
A Abrami, F Arfelli, RC Barroso, A Bergamaschi, F Bille, P Bregant, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2005
1342005
Modelling of a novel x-ray phase contrast imaging technique based on coded apertures
A Olivo, R Speller
Physics in Medicine & Biology 52 (22), 6555, 2007
1262007
Low‐dose phase contrast mammography with conventional x‐ray sources
A Olivo, S Gkoumas, M Endrizzi, CK Hagen, MB Szafraniec, PC Diemoz, ...
Medical physics 40 (9), 090701, 2013
1102013
The Dexela 2923 CMOS X-ray detector: A flat panel detector based on CMOS active pixel sensors for medical imaging applications
AC Konstantinidis, MB Szafraniec, RD Speller, A Olivo
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2012
1062012
Rabbit pilot study on the resorbability of three-dimensional bioactive glass fibre scaffolds
L Moimas, M Biasotto, R Di Lenarda, A Olivo, C Schmid
Acta biomaterialia 2 (2), 191-199, 2006
942006
Optimization of liver decellularization maintains extracellular matrix micro-architecture and composition predisposing to effective cell seeding
P Maghsoudlou, F Georgiades, H Smith, A Milan, P Shangaris, L Urbani, ...
PloS one 11 (5), e0155324, 2016
912016
X-ray phase-contrast imaging with nanoradian angular resolution
PC Diemoz, M Endrizzi, CE Zapata, ZD Pešić, C Rau, A Bravin, ...
Physical review letters 110 (13), 138105, 2013
882013
Spatial resolution of edge illumination X-ray phase-contrast imaging
PC Diemoz, FA Vittoria, A Olivo
Optics express 22 (13), 15514-15529, 2014
862014
X-ray phase contrast imaging: From synchrotrons to conventional sources
A Olivo, E Castelli
La rivista del nuovo cimento 37, 467-508, 2014
842014
Sensitivity of laboratory based implementations of edge illumination X-ray phase-contrast imaging
PC Diemoz, CK Hagen, M Endrizzi, A Olivo
Applied Physics Letters 103 (24), 2013
822013
Low‐dose phase contrast tomography with conventional x‐ray sources
CK Hagen, PRT Munro, M Endrizzi, PC Diemoz, A Olivo
Medical physics 41 (7), 070701, 2014
762014
A simplified approach to quantitative coded aperture x-ray phase imaging
PRT Munro, CK Hagen, MB Szafraniec, A Olivo
Optics express 21 (9), 11187-11201, 2013
742013
Beam tracking approach for single–shot retrieval of absorption, refraction, and dark–field signals with laboratory x–ray sources
FA Vittoria, GKN Kallon, D Basta, PC Diemoz, IK Robinson, A Olivo, ...
Applied Physics Letters 106 (22), 2015
722015
The effects of the imaging system on the validity limits of the ray‐optical approach to phase contrast imaging
A Peterzol, A Olivo, L Rigon, S Pani, D Dreossi
Medical physics 32 (12), 3617-3627, 2005
712005
系统目前无法执行此操作,请稍后再试。