关注
Bruno De Man
Bruno De Man
Chief Scientist, GE Research
在 ge.com 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Distance-driven projection and backprojection in three dimensions
B De Man, S Basu
Physics in Medicine & Biology 49 (11), 2463, 2004
6652004
An iterative maximum-likelihood polychromatic algorithm for CT
B De Man, J Nuyts, P Dupont, G Marchal, P Suetens
IEEE transactions on medical imaging 20 (10), 999-1008, 2001
5722001
Metal streak artifacts in X-ray computed tomography: a simulation study
B De Man, J Nuyts, P Dupont, G Marchal, P Suetens
1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear …, 1998
4361998
An outlook on x‐ray CT research and development
G Wang, H Yu, B De Man
Medical physics 35 (3), 1051-1064, 2008
4282008
Deep learning for tomographic image reconstruction
G Wang, JC Ye, B De Man
Nature machine intelligence 2 (12), 737-748, 2020
4082020
Iterative reconstruction for helical CT: a simulation study
J Nuyts, B De Man, P Dupont, M Defrise, P Suetens, L Mortelmans
Physics in Medicine & Biology 43 (4), 729, 1998
3631998
Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm
B De Man, J Nuyts, P Dupont, G Marchal, P Suetens
IEEE transactions on nuclear science 47 (3), 977-981, 2000
3372000
Metal artifact reduction in CT: where are we after four decades?
L Gjesteby, B De Man, Y Jin, H Paganetti, J Verburg, D Giantsoudi, ...
Ieee Access 4, 5826-5849, 2016
2732016
Modelling the physics in the iterative reconstruction for transmission computed tomography
J Nuyts, B De Man, JA Fessler, W Zbijewski, FJ Beekman
Physics in Medicine & Biology 58 (12), R63, 2013
2662013
Dual-energy computed tomography: physical principles, approaches to scanning, usage, and implementation: part 1
R Forghani, B De Man, R Gupta
Neuroimaging Clinics 27 (3), 371-384, 2017
2012017
CatSim: a new computer assisted tomography simulation environment
B De Man, S Basu, N Chandra, B Dunham, P Edic, M Iatrou, S McOlash, ...
Medical Imaging 2007: Physics of Medical Imaging 6510, 856-863, 2007
1782007
Metal artifacts in computed tomography for radiation therapy planning: dosimetric effects and impact of metal artifact reduction
D Giantsoudi, B De Man, J Verburg, A Trofimov, Y Jin, G Wang, ...
Physics in Medicine & Biology 62 (8), R49, 2017
1492017
Distance-driven projection and backprojection
B De Man, S Basu
2002 IEEE Nuclear Science Symposium Conference Record 3, 1477-1480, 2002
1432002
Deep learning medical systems and methods for image reconstruction and quality evaluation
J Hsieh, G Avinash, S Sirohey, X Wang, Z Yin, B De Man
US Patent 10,074,038, 2018
1392018
Stationary computed tomography system and method
BKB De Man, SK Basu, PM Edic, RF Senzig, WR Ross, X Wu, CR Wilson, ...
US Patent 7,280,631, 2007
1292007
Ultra-low dose CT attenuation correction for PET/CT
T Xia, AM Alessio, B De Man, R Manjeshwar, E Asma, PE Kinahan
Physics in Medicine & Biology 57 (2), 309, 2011
1252011
Method and apparatus for calibrating volumetric computed tomography systems
SK Basu, PM Edic, BKB De Man
US Patent 7,016,456, 2006
1202006
Method and system for imaging using multiple offset X-ray emission points
B De Man, PM Edic, S Basu
US Patent 7,333,587, 2008
1192008
System and method for boundary estimation using CT metrology
BKB De Man, SK Basu, JC Ye
US Patent 7,203,267, 2007
1172007
System and method for detecting an object
FF Hopkins, PM Edic, SK Basu, B De Man, JW Leblanc, X Wu, DJ Walter, ...
US Patent 7,492,855, 2009
1022009
系统目前无法执行此操作,请稍后再试。
文章 1–20