关注
Chumin Zhao
Chumin Zhao
在 fda.hhs.gov 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
DC sputtered amorphous In–Sn–Zn–O thin-film transistors: Electrical properties and stability
M Nakata, C Zhao, J Kanicki
Solid-State Electronics 116, 22-29, 2016
532016
Large area CMOS active pixel sensor x‐ray imager for digital breast tomosynthesis: analysis, modeling, and characterization
C Zhao, J Kanicki, AC Konstantinidis, T Patel
Medical physics 42 (11), 6294-6308, 2015
532015
Amorphous In–Ga–Zn–O thin‐film transistor active pixel sensor x‐ray imager for digital breast tomosynthesis
C Zhao, J Kanicki
Medical physics 41 (9), 091902, 2014
502014
Top illuminated organic photodetectors with dielectric/metal/dielectric transparent anode
H Kim, KT Lee, C Zhao, LJ Guo, J Kanicki
Organic electronics 20, 103-111, 2015
402015
50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis
C Zhao, AC Konstantinidis, Y Zheng, T Anaxagoras, RD Speller, J Kanicki
Physics in Medicine & Biology 60 (23), 8977, 2015
342015
Half-Corbino short-channel amorphous In–Ga–Zn–O thin-film transistors with a-SiOx or a-SiOx/a-SiNx passivation layers
C Zhao, TC Fung, J Kanicki
Solid-State Electronics 120, 25-31, 2016
222016
Amorphous InSnZnO thin-film transistor voltage-mode active pixel sensor circuits for indirect X-ray imagers
MH Cheng, C Zhao, CL Huang, H Kim, M Nakata, J Kanicki
IEEE Transactions on Electron Devices 63 (12), 4802-4810, 2016
212016
Two-dimensional numerical simulation of bottom-gate and dual-gate amorphous In-Ga-Zn-O MESFETs
C Zhao, L Bie, R Zhang, J Kanicki
IEEE electron device letters 35 (1), 75-77, 2013
192013
Cone‐beam imaging with tilted rotation axis: method and performance evaluation
C Zhao, M Herbst, S Vogt, L Ritschl, S Kappler, JH Siewerdsen, ...
Medical physics 47 (8), 3305-3320, 2020
162020
A robotic X-ray cone-beam CT system: trajectory optimization for 3D imaging of the weight-bearing spine
C Zhao, M Herbst, S Vogt, L Ritschl, S Kappler, JH Siewerdsen, ...
Medical Imaging 2019: Physics of Medical Imaging 10948, 399-405, 2019
162019
Study of current-mode active pixel sensor circuits using amorphous InSnZnO thin-film transistor for 50-μm pixel-pitch indirect x-ray imagers
MH Cheng, C Zhao, J Kanicki
Solid-State Electronics 131, 53-64, 2017
132017
Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis
C Zhao, N Vassiljev, AC Konstantinidis, RD Speller, J Kanicki
Physics in Medicine & Biology 62 (5), 1994, 2017
122017
Effects of x-ray scatter in quantitative dual-energy imaging using dual-layer flat panel detectors
C Zhao, SZ Liu, W Wang, M Herbst, T Weber, S Vogt, L Ritschl, S Kappler, ...
Medical Imaging 2021: Physics of Medical Imaging 11595, 595-600, 2021
102021
Spatiotemporal image quality of virtual reality head mounted displays
C Zhao, AS Kim, R Beams, A Badano
Scientific Reports 12 (1), 20235, 2022
92022
Cascaded systems analysis of a-Se/a-Si and a-InGaZnO TFT passive and active pixel sensors for tomosynthesis
A Sengupta, C Zhao, A Konstantinidis, J Kanicki
Physics in Medicine & Biology 64 (2), 025012, 2019
92019
High performance amorphous metal-oxide semiconductors thin-film passive and active pixel sensors
R Zhang, L Bie, TC Fung, EKH Yu, C Zhao, J Kanicki
2013 IEEE International Electron Devices Meeting, 27.3. 1-27.3. 4, 2013
92013
Sensor circuits for x-ray imagers
J Kanicki, MH Cheng, C Zhao, A Sengupta
US Patent App. 16/165,816, 2019
82019
Task-based modeling of a 5K ultra-high-resolution medical imaging system for digital breast tomosynthesis
C Zhao, J Kanicki
IEEE Transactions on Medical Imaging 36 (9), 1820-1831, 2017
72017
Feasibility of dual-energy cone-beam CT of bone marrow edema using dual-layer flat panel detectors
SZ Liu, C Zhao, M Herbst, T Weber, S Vogt, L Ritschl, S Kappler, ...
Medical Imaging 2022: Physics of Medical Imaging 12031, 379-386, 2022
62022
Radially variant contrast measurement in virtual reality headsets using circular concentric ring patterns
C Zhao, R Beams, A Badano
Journal of the Society for Information Display 31 (5), 387-397, 2023
52023
系统目前无法执行此操作,请稍后再试。
文章 1–20