关注
Kavita Arora
Kavita Arora
在 jnu.ac.in 的电子邮件经过验证
标题
引用次数
引用次数
年份
Graphene oxide-chitosan nanocomposite based electrochemical DNA biosensor for detection of typhoid
A Singh, G Sinsinbar, M Choudhary, V Kumar, R Pasricha, HN Verma, ...
Sensors and Actuators B: Chemical 185, 675-684, 2013
2562013
Application of electrochemically prepared polypyrrole–polyvinyl sulphonate films to DNA biosensor
K Arora, A Chaubey, R Singhal, RP Singh, MK Pandey, SB Samanta, ...
Biosensors and Bioelectronics 21 (9), 1777-1783, 2006
1672006
Chemical analysis of food: Techniques and applications
Y Picó
Academic Press, 2012
1342012
Anti-IL8/AuNPs-rGO/ITO as an immunosensing platform for noninvasive electrochemical detection of oral cancer
S Verma, A Singh, A Shukla, J Kaswan, K Arora, J Ramirez-Vick, P Singh, ...
ACS applied materials & interfaces 9 (33), 27462-27474, 2017
1322017
Recent developments in bio-molecular electronics techniques for food pathogens
K Arora, S Chand, BD Malhotra
Analytica Chimica Acta 568 (1-2), 259-274, 2006
1212006
Improved performance of polyaniline-uricase biosensor
K Arora, G Sumana, V Saxena, RK Gupta, SK Gupta, JV Yakhmi, ...
Analytica chimica acta 594 (1), 17-23, 2007
1122007
E scherichia coli Genosensor Based on Polyaniline
K Arora, N Prabhakar, S Chand, BD Malhotra
Analytical Chemistry 79 (16), 6152-6158, 2007
1112007
Ultrasensitive DNA hybridization biosensor based on polyaniline
K Arora, N Prabhakar, S Chand, BD Malhotra
Biosensors and Bioelectronics 23 (5), 613-620, 2007
1092007
Nucleic acid sensor for M. tuberculosis detection based on surface plasmon resonance
N Prabhakar, K Arora, SK Arya, PR Solanki, M Iwamoto, H Singh, ...
Analyst 133 (11), 1587-1592, 2008
972008
CD 59 targeted ultrasensitive electrochemical immunosensor for fast and noninvasive diagnosis of oral cancer
M Choudhary, P Yadav, A Singh, S Kaur, J Ramirez‐Vick, P Chandra, ...
Electroanalysis 28 (10), 2565-2574, 2016
922016
Polyaniline based nucleic acid sensor
N Prabhakar, K Arora, H Singh, BD Malhotra
The Journal of Physical Chemistry B 112 (15), 4808-4816, 2008
852008
Trends in nano-inspired biosensors for plants
V Kumar, K Arora
Materials Science for Energy Technologies 3, 255-273, 2020
832020
Immobilization of single stranded DNA probe onto polypyrrole-polyvinyl sulfonate for application to DNA hybridization biosensor
K Arora, N Prabhakar, S Chand, BD Malhotra
Sensors and Actuators B: Chemical 126 (2), 655-663, 2007
752007
Polypyrrole-polyvinyl sulphonate film based disposable nucleic acid biosensor
N Prabhakar, K Arora, SP Singh, MK Pandey, H Singh, BD Malhotra
Analytica chimica acta 589 (1), 6-13, 2007
752007
Polypyrrole-polyvinyl sulphonate film based disposable nucleic acid biosensor.
MBD Prabhakar N , Arora K , Singh SP , Pandey MK , Singh H
Analytica Chimica Acta 589 (1), 6, 2007
752007
STD sensor based on nucleic acid functionalized nanostructured polyaniline
R Singh, R Prasad, G Sumana, K Arora, S Sood, RK Gupta, BD Malhotra
Biosensors and Bioelectronics 24 (7), 2232-2238, 2009
702009
Improved electrochemical nucleic acid biosensor based on polyaniline-polyvinyl sulphonate
N Prabhakar, G Sumana, K Arora, H Singh, BD Malhotra
Electrochimica Acta 53 (12), 4344-4350, 2008
592008
DNA entrapped polypyrrole–polyvinyl sulfonate film for application to electrochemical biosensor
N Prabhakar, K Arora, SP Singh, H Singh, BD Malhotra
Analytical biochemistry 366 (1), 71-79, 2007
592007
Nucleic acid immobilized polypyrrole–polyvinylsulphonate film for Mycobacterium tuberculosis detection
N Prabhakar, H Singh, BD Malhotra
Electrochemistry Communications 10 (6), 821-826, 2008
462008
DNA functionalized direct electro-deposited gold nanoaggregates for efficient detection of Salmonella typhi
A Singh, M Choudhary, MP Singh, HN Verma, SP Singh, K Arora
Bioelectrochemistry 105, 7-15, 2015
422015
系统目前无法执行此操作,请稍后再试。
文章 1–20