关注
Guillaume Haiat
Guillaume Haiat
CNRS
在 univ-paris-est.fr 的电子邮件经过验证
标题
引用次数
引用次数
年份
Bone quantitative ultrasound
P Laugier, G Haïat
Springer, 2011
3992011
Biomechanical behaviours of the bone–implant interface: a review
X Gao, M Fraulob, G Haïat
Journal of The Royal Society Interface 16 (156), 20190259, 2019
2022019
Biomechanical determinants of the stability of dental implants: Influence of the bone–implant interface properties
V Mathieu, R Vayron, G Richard, G Lambert, S Naili, JP Meningaud, ...
Journal of biomechanics 47 (1), 3-13, 2014
2002014
Effects of biomechanical properties of the bone–implant interface on dental implant stability: from in silico approaches to the patient's mouth
G Haïat, HL Wang, J Brunski
Annual Review of Biomedical Engineering 16 (1), 187-213, 2014
1502014
Introduction to the physics of ultrasound
P Laugier, G Haïat
Bone quantitative ultrasound, 29-45, 2011
1382011
Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3D model simulation
G Haïat, F Padilla, F Peyrin, P Laugier
Journal of Bone and Mineral Research 22 (5), 665-674, 2007
1372007
Determination of the heterogeneous anisotropic elastic properties of human femoral bone: from nanoscopic to organ scale
V Sansalone, S Naili, V Bousson, C Bergot, F Peyrin, J Zarka, JD Laredo, ...
Journal of Biomechanics 43 (10), 1857-1863, 2010
1262010
Fast wave ultrasonic propagation in trabecular bone: Numerical study of the influence of porosity and structural anisotropy
G Haiat, F Padilla, F Peyrin, P Laugier
The Journal of the Acoustical Society of America 123 (3), 1694-1705, 2008
1082008
The adhesive contact of viscoelastic spheres
G Haiat, MCP Huy, E Barthel
Journal of the Mechanics and Physics of Solids 51 (1), 69-99, 2003
1062003
Frequency dependence of ultrasonic attenuation in bovine cortical bone: an in vitro study
M Sasso, G Haïat, Y Yamato, S Naili, M Matsukawa
Ultrasound in medicine & biology 33 (12), 1933-1942, 2007
972007
Dependence of ultrasonic attenuation on bone mass and microstructure in bovine cortical bone
M Sasso, G Haïat, YU Yamato, S Naili, M Matsukawa
Journal of Biomechanics 41 (2), 347-355, 2008
942008
Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone: Application to axial transmission
G Haïat, S Naili, Q Grimal, M Talmant, C Desceliers, C Soize
The Journal of the Acoustical Society of America 125 (6), 4043-4052, 2009
932009
Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study
V Mathieu, F Anagnostou, E Soffer, G Haïat
Ultrasound in medicine & biology 37 (2), 262-270, 2011
852011
Stress shielding at the bone‐implant interface: Influence of surface roughness and of the bone‐implant contact ratio
ML Raffa, VH Nguyen, P Hernigou, CH Flouzat‐Lachaniette, G Haiat
Journal of Orthopaedic Research® 39 (6), 1174-1183, 2021
832021
Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant
V Mathieu, K Fukui, M Matsukawa, M Kawabe, R Vayron, E Soffer, ...
822011
A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur
R Barkmann, P Laugier, U Moser, S Dencks, F Padilla, G Haiat, M Heller, ...
Bone 40 (1), 37-44, 2007
822007
Velocity dispersion in trabecular bone: influence of multiple scattering and of absorption
G Haiat, A Lhemery, F Renaud, F Padilla, P Laugier, S Naili
The Journal of the Acoustical Society of America 124 (6), 4047-4058, 2008
762008
Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant
R Vayron, E Barthel, V Mathieu, E Soffer, F Anagnostou, G Haiat
712012
Ultrasonic evaluation of dental implant osseointegration
R Vayron, E Soffer, F Anagnostou, G Haïat
Journal of biomechanics 47 (14), 3562-3568, 2014
662014
Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability
V Mathieu, F Anagnostou, E Soffer, G Haiat
The Journal of the Acoustical Society of America 129 (6), 4062-4072, 2011
622011
系统目前无法执行此操作,请稍后再试。
文章 1–20