Active‐passive gradient shielding for MRI acoustic noise reduction WA Edelstein, TK Kidane, V Taracila, TN Baig, TP Eagan, YCN Cheng, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2005 | 79 | 2005 |
Conduction cooled magnet design for 1.5 T, 3.0 T and 7.0 T MRI systems T Baig, Z Yao, D Doll, M Tomsic, M Martens Superconductor Science and Technology 27 (12), 125012, 2014 | 66 | 2014 |
Conceptual designs of conduction cooled MgB2 magnets for 1.5 and 3.0 T full body MRI systems T Baig, A Al Amin, RJ Deissler, L Sabri, C Poole, RW Brown, M Tomsic, ... Superconductor Science and Technology 30 (4), 043002, 2017 | 62 | 2017 |
Measurements and simulation of RF heating of implanted stereo‐electroencephalography electrodes during MR scans B Bhusal, P Bhattacharyya, T Baig, S Jones, M Martens Magnetic resonance in medicine 80 (4), 1676-1685, 2018 | 39 | 2018 |
Computational homogenization of the elastic and thermal properties of superconducting composite MgB2 wire A Al Amin, L Sabri, C Poole, T Baig, RJ Deissler, M Rindfleisch, D Doll, ... Composite Structures 188, 313-329, 2018 | 38 | 2018 |
Numerical study on the quench propagation in a 1.5 T MgB2 MRI magnet design with varied wire compositions C Poole, T Baig, RJ Deissler, D Doll, M Tomsic, M Martens Superconductor Science and Technology 29 (4), 044003, 2016 | 36 | 2016 |
Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating N Gudino, M Sonmez, Z Yao, T Baig, S Nielles‐Vallespin, AZ Faranesh, ... Medical physics 42 (1), 359-371, 2015 | 33 | 2015 |
A multiscale and multiphysics model of strain development in a 1.5 T MRI magnet designed with 36 filament composite MgB2 superconducting wire A Al Amin, T Baig, RJ Deissler, Z Yao, M Tomsic, D Doll, O Akkus, ... Superconductor Science and Technology 29 (5), 055008, 2016 | 29 | 2016 |
Active-passive electromagnetic shielding to reduce MRI acoustic noise WA Edelstein, TK Kidane, V Taracilla, TN Baig, TP Eagan, RW Brown US Patent 7,375,526, 2008 | 26 | 2008 |
Active-passive electromagnetic shielding to reduce MRI acoustic noise WA Edelstein, TK Kidane, V Taracilla, TN Baig, TP Eagan, RW Brown US Patent 7,141,974, 2006 | 22 | 2006 |
Active-passive shielding for MRI acoustic noise reduction: Network analysis TK Kidane, WA Edelstein, TP Eagan, V Taracila, TN Baig, YN Cheng, ... IEEE transactions on magnetics 42 (12), 3854-3860, 2006 | 22 | 2006 |
Numerical simulation of quench protection for a 1.5 T persistent mode MgB2 conduction-cooled MRI magnet RJ Deissler, T Baig, C Poole, A Amin, D Doll, M Tomsic, M Martens Superconductor Science and Technology 30 (2), 025021, 2016 | 20 | 2016 |
The suppression of selected acoustic frequencies in MRI X Shou, X Chen, J Derakhshan, T Eagan, T Baig, S Shvartsman, J Duerk, ... Applied Acoustics 71 (3), 191-200, 2010 | 20 | 2010 |
Ventilation mapping of chest using Focused Impedance Method (FIM) MA Kadir, H Ferdous, TN Baig, K Siddique-e-Rabbani Journal of Physics: Conference Series 224 (1), 012031, 2010 | 15 | 2010 |
Instrumentation, cooling, and initial testing of a large, conduction-cooled, react-and-wind MgB2 coil segment for MRI applications D Zhang, C Kovacs, J Rochester, M Majoros, F Wan, MD Sumption, ... Superconductor Science and Technology 31 (8), 085013, 2018 | 14 | 2018 |
Focused impedance method to detect localized lung ventilation disorders in combination with conventional spirometry MA Kadir, TN Baig, KS Rabbani Biomedical Engineering: Applications, Basis and Communications 27 (03), 1550029, 2015 | 14 | 2015 |
Gradient coil with active endcap shielding TN Baig, TP Eagan, LS Petropoulos, TK Kidane, WA Edelstein, RW Brown Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering: An …, 2007 | 13 | 2007 |
Analytical calculation of cylindrical shell modes: Implications for MRI acoustic noise V Taracila, WA Edelstein, TK Kidane, TP Eagan, TN Baig, RW Brown Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering: An …, 2005 | 13 | 2005 |
Use of Distribution of F-latency (DFL) in the Detection of Cervical Spondylotic Neuropathy MI Hossain, EA Chowdhury, AA Mamun, A Salam, TN Baig, KS Rabbani Bangladesh Journal of Medical Physics Vol 4 (1), 2011 | 11 | 2011 |
A New Instrument Designed to Measure the Magnetic Susceptibility of Human Liver Tissue In Vivo DE Farrell, CJ Allen, MW Whilden, TK Kidane, TN Baig, JH Tripp, ... IEEE transactions on magnetics 43 (9), 3543-3554, 2007 | 11 | 2007 |