Ultra-sensitive microfluidic wearable strain sensor for intraocular pressure monitoring S Agaoglu, P Diep, M Martini, KT Samudhyatha, M Baday, IE Araci Lab on a Chip 18 (22), 3471-3483, 2018 | 79 | 2018 |
A statistical perspective to visual masking S Agaoglu, MN Agaoglu, B Breitmeyer, H Ogmen Vision Research 115, 23-39, 2015 | 35 | 2015 |
Flow stabilization in wearable microfluidic sensors enables noise suppression IE Araci, S Agaoglu, JY Lee, LR Yepes, P Diep, M Martini, A Schmidt Lab on a Chip 19 (22), 3899-3908, 2019 | 26 | 2019 |
Metacontrast masking and attention do not interact S Agaoglu, B Breitmeyer, H Ogmen Attention, Perception, & Psychophysics 78, 1363-1380, 2016 | 20 | 2016 |
Neural plasticity following surgical correction of strabismus in monkeys M Pullela, MN Ağaoğlu, AC Joshi, S Agaoglu, DK Coats, VE Das Investigative Ophthalmology & Visual Science 59 (12), 5011-5021, 2018 | 17 | 2018 |
Motion Information via the Nonfixating Eye Can Drive Optokinetic Nystagmus in Strabismus S Agaoglu, MN Agaoglu, VE Das Investigative ophthalmology & visual science 56 (11), 6423-6432, 2015 | 15 | 2015 |
The effect of pre-polymer/cross-linker storage on the elasticity and reliability of PDMS microfluidic devices S Agaoglu, MC Robles, CD Smith, SR Quake, IE Araci Microfluidics and Nanofluidics 21, 1-8, 2017 | 14 | 2017 |
Closed microfluidic network for strain sensing embedded in a contact lens to monitor intraocular pressure IE Araci, S Agaoglu, M Baday, P Diep US Patent 10,898,074, 2021 | 7 | 2021 |
Effects of exogenous and endogenous attention on metacontrast masking S Agaoglu, B Breitmeyer, H Ogmen Vision 2 (4), 39, 2018 | 7 | 2018 |
Surgical correction of strabismus in monkeys: III. Longitudinal evaluation of neuronal responses in the abducens nucleus MN Agaoglu, M Pullela, AC Joshi, S Agaoglu, DK Coats, VE Das Investigative Ophthalmology & Visual Science 56 (7), 5222-5222, 2015 | 4 | 2015 |
Surgical correction of strabismus in monkeys: II. Longitudinal evaluation of neuronal responses in the oculomotor nucleus M Pullela, MN Agaoglu, AC Joshi, S Agaoglu, DK Coats, VE Das Investigative Ophthalmology & Visual Science 56 (7), 5221-5221, 2015 | 4 | 2015 |
How do Endogenous Attention, Exogenous Attention and Metacontrast Masking Operate in Controlling Stimulus Visibility? H Ogmen, S Agaoglu, B Breitmeyer Journal of Vision 16 (12), 898-898, 2016 | 3 | 2016 |
Abducens neuron responses in monkeys with strabismus MN Agaoglu, AC Joshi, S Agaoglu, VE Das Investigative Ophthalmology & Visual Science 55 (13), 2572-2572, 2014 | 3 | 2014 |
Method and device for remote optical monitoring of intraocular pressure A Dana, S Agaoglu, AT Yazici, M Baday, S Komban US Patent App. 17/370,735, 2021 | 2 | 2021 |
Attention and Metacontrast Masking do not Interact S Agaoglu, B Breitmeyer, H Ogmen Journal of Vision 16 (12), 1267-1267, 2016 | 1 | 2016 |
A Statistical Approach to Visual Masking and Spatial Attention S Agaoglu | 1 | 2015 |
Closed microfluidic network for strain sensing embedded in a contact lens to monitor intraocular pressure IE Araci, S Agaoglu, M Baday, P Diep US Patent App. 18/500,766, 2024 | | 2024 |
Method and device for remote optical monitoring of intraocular pressure A Dana, AT Yazici, S Agaoglu, S Komban, M Baday US Patent App. 18/446,731, 2023 | | 2023 |
Closed microfluidic network for strain sensing embedded in a contact lens to monitor intraocular pressure IE Araci, S Agaoglu, M Baday, P Diep US Patent App. 18/447,033, 2023 | | 2023 |
Closed microfluidic network for strain sensing embedded in a contact lens to monitor intraocular pressure IE Araci, S Agaoglu, M Baday, P Diep US Patent 11,759,107, 2023 | | 2023 |