关注
Siavash Yazdanfar
Siavash Yazdanfar
在 corning.com 的电子邮件经过验证
标题
引用次数
引用次数
年份
In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
JA Izatt, MD Kulkarni, S Yazdanfar, JK Barton, AJ Welch
Optics letters 22 (18), 1439-1441, 1997
9801997
Real-time optical coherence tomography of the anterior segment at 1310 nm
S Radhakrishnan, AM Rollins, JE Roth, S Yazdanfar, V Westphal, ...
Archives of ophthalmology 119 (8), 1179-1185, 2001
9782001
In vivo video rate optical coherence tomography
AM Rollins, MD Kulkarni, S Yazdanfar, R Ung-Arunyawee, JA Izatt
Optics express 3 (6), 219-229, 1998
6491998
Imaging and velocimetry of the human retinal circulation with color Doppler optical coherence tomography
S Yazdanfar, AM Rollins, JA Izatt
Optics letters 25 (19), 1448-1450, 2000
3872000
High resolution imaging of in vivo cardiac dynamics using color Doppler optical coherence tomography
S Yazdanfar, MD Kulkarni, JA Izatt
Optics express 1 (13), 424-431, 1997
3861997
In vivo imaging of human retinal flow dynamics by color Doppler optical coherence tomography
S Yazdanfar, AM Rollins, JA Izatt
Archives of ophthalmology 121 (2), 235-239, 2003
3312003
Aspects of basic OCT engine technologies for high speed optical coherence tomography and light source and other improvements in optical coherence tomography
AM Rollins, JA Izatt, V Westphal, S Yazdanfar
US Patent 7,061,622, 2006
2902006
Doppler flow imaging using optical coherence tomography
JA Izatt, MD Kulkarni, S Yazdanfar, A Rollins, MV Sivak
US Patent 6,735,463, 2004
2902004
Detection of colorectal polyps in humans using an intravenously administered fluorescent peptide targeted against c-Met
J Burggraaf, IMC Kamerling, PB Gordon, L Schrier, ML De Kam, AJ Kales, ...
Nature medicine 21 (8), 955-961, 2015
2872015
Method for optical coherence tomography imaging with molecular contrast
JA Izatt, DK Rao, C Yang, MA Choma, S Yazdanfar, AM Rollins, ...
US Patent 7,075,658, 2006
2872006
Real-time, high velocity-resolution color Doppler optical coherence tomography
V Westphal, S Yazdanfar, AM Rollins, JA Izatt
Optics Letters 27 (1), 34-36, 2002
2762002
Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography
MD Kulkarni, TG van Leeuwen, S Yazdanfar, JA Izatt
Optics Letters 23 (13), 1057-1059, 1998
2731998
Real-time in vivo color Doppler optical coherence tomography
AM Rollins, S Yazdanfar, JK Barton, JA Izatt
Journal of Biomedical Optics 7 (1), 123-129, 2002
2692002
Simplified method for polarization-sensitive optical coherence tomography
JE Roth, JA Kozak, S Yazdanfar, AM Rollins, JA Izatt
Optics Letters 26 (14), 1069-1071, 2001
2502001
Three-dimensional reconstruction of blood vessels from in vivo color Doppler optical coherence tomography images
J Kehlet Barton, JA Izatt, MD Kulkarni, S Yazdanfar, AJ Welch
Dermatology 198 (4), 355-361, 1999
2391999
Frequency estimation precision in Doppler optical coherence tomography using the Cramer-Rao lower bound
S Yazdanfar, C Yang, MV Sarunic, JA Izatt
Optics express 13 (2), 410-416, 2005
2352005
High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography
TG van Leeuwen, MD Kulkarni, S Yazdanfar, AM Rollins, JA Izatt
Optics Letters 24 (22), 1584-1586, 1999
2241999
Doppler flow imaging using optical coherence tomography
JA Izatt, MD Kulkarni, S Yazdanfar, A Rollins, MV Sivak
US Patent 6,006,128, 1999
2151999
Photothermal coagulation of blood vessels: a comparison of high-speed optical coherence tomography and numerical modelling
JK Barton, A Rollins, S Yazdanfar, TJ Pfefer, V Westphal, JA Izatt
Physics in Medicine & Biology 46 (6), 1665, 2001
2102001
Simple and robust image-based autofocusing for digital microscopy
S Yazdanfar, KB Kenny, K Tasimi, AD Corwin, EL Dixon, RJ Filkins
Optics express 16 (12), 8670-8677, 2008
2052008
系统目前无法执行此操作,请稍后再试。
文章 1–20