关注
Jie Shan
Jie Shan
在 mayo.edu 的电子邮件经过验证
标题
引用次数
引用次数
年份
Robust intensity‐modulated proton therapy to reduce high linear energy transfer in organs at risk
Y An, J Shan, SH Patel, W Wong, SE Schild, X Ding, M Bues, W Liu
Medical physics 44 (12), 6138-6147, 2017
872017
Robust optimization for intensity modulated proton therapy to redistribute high linear energy transfer from nearby critical organs to tumors in head and neck cancer
C Liu, SH Patel, J Shan, SE Schild, CE Vargas, WW Wong, X Ding, ...
International Journal of Radiation Oncology* Biology* Physics 107 (1), 181-193, 2020
702020
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies
C Liu, RS Bhangoo, TT Sio, NY Yu, J Shan, JS Chiang, JX Ding, WG Rule, ...
Journal of applied clinical medical physics 20 (7), 15-27, 2019
562019
Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint
J Shan, Y An, M Bues, SE Schild, W Liu
Medical physics 45 (1), 460-469, 2018
532018
Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy
W Deng, JE Younkin, K Souris, S Huang, K Augustine, M Fatyga, X Ding, ...
Medical physics 47 (6), 2558-2574, 2020
512020
Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: a dosimetric comparative study
C Liu, TT Sio, W Deng, J Shan, TB Daniels, WG Rule, PR Lara, SM Korte, ...
Journal of applied clinical medical physics 19 (6), 140-148, 2018
502018
Intensity‐modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non‐small cell lung …
J Shan, Y Yang, SE Schild, TB Daniels, WW Wong, M Fatyga, M Bues, ...
Medical physics 47 (11), 5428-5440, 2020
362020
Treatment planning system (TPS) approximations matter—comparing intensity‐modulated proton therapy (IMPT) plan quality and robustness between a commercial and an in‐house …
C Liu, NY Yu, J Shan, RS Bhangoo, TB Daniels, JS Chiang, X Ding, ...
Medical physics 46 (11), 4755-4762, 2019
282019
Early outcomes of patients with locally advanced non-small cell lung cancer treated with intensity-modulated proton therapy versus intensity-modulated radiation therapy: the …
YY Nathan, TA DeWees, C Liu, TB Daniels, JB Ashman, SE Beamer, ...
Advances in Radiation Oncology 5 (3), 450-458, 2020
272020
4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma
H Feng, J Shan, JB Ashman, WG Rule, RS Bhangoo, NY Yu, J Chiang, ...
Medical physics 48 (8), 4636-4647, 2021
252021
A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity‐modulated proton radiotherapy
J Shan, TT Sio, C Liu, SE Schild, M Bues, W Liu
Medical physics 46 (1), 382-393, 2019
252019
Per‐voxel constraints to minimize hot spots in linear energy transfer‐guided robust optimization for base of skull head and neck cancer patients in IMPT
H Feng, J Shan, JD Anderson, WW Wong, SE Schild, RL Foote, ...
Medical physics 49 (1), 632-647, 2022
232022
Clinical validation of a ray-casting analytical dose engine for spot scanning proton delivery systems
JE Younkin, DH Morales, J Shen, J Shan, M Bues, JM Lentz, SE Schild, ...
Technology in Cancer Research & Treatment 18, 1533033819887182, 2019
212019
Automation of routine elements for spot‐scanning proton patient‐specific quality assurance
D Hernandez Morales, J Shan, W Liu, KE Augustine, M Bues, MJ Davis, ...
Medical physics 46 (1), 5-14, 2019
182019
Virtual particle Monte Carlo: A new concept to avoid simulating secondary particles in proton therapy dose calculation
J Shan, H Feng, DH Morales, SH Patel, WW Wong, M Fatyga, M Bues, ...
Medical physics 49 (10), 6666-6683, 2022
162022
Mixed integer programming with dose‐volume constraints in intensity‐modulated proton therapy
P Zhang, N Fan, J Shan, SE Schild, M Bues, W Liu
Journal of applied clinical medical physics 18 (5), 29-35, 2017
152017
Evaluation and second check of a commercial Monte Carlo dose engine for small‐field apertures in pencil beam scanning proton therapy
J Holmes, J Shen, J Shan, CL Patrick, WW Wong, RL Foote, SH Patel, ...
Medical physics 49 (5), 3497-3506, 2022
132022
System and Method for Robust Treatment Planning in Radiation Therapy
W Liu, J Shan
US Patent App. 17/271,751, 2021
12021
A method for quantitative evaluations of scanning‐proton dose distributions
BC Allred, J Shan, DG Robertson, TA DeWees, J Shen, W Liu, JB Stoker
Journal of applied clinical medical physics 22 (4), 193-201, 2021
12021
Virtual Particle Based Monte Carlo Dose Calculation for Charged Particle Therapy Treatment Planning
W Liu, J Shan
US Patent App. 17/832,122, 2023
2023
系统目前无法执行此操作,请稍后再试。
文章 1–20