Robust intensity‐modulated proton therapy to reduce high linear energy transfer in organs at risk Y An, J Shan, SH Patel, W Wong, SE Schild, X Ding, M Bues, W Liu Medical physics 44 (12), 6138-6147, 2017 | 87 | 2017 |
Robust optimization for intensity modulated proton therapy to redistribute high linear energy transfer from nearby critical organs to tumors in head and neck cancer C Liu, SH Patel, J Shan, SE Schild, CE Vargas, WW Wong, X Ding, ... International Journal of Radiation Oncology* Biology* Physics 107 (1), 181-193, 2020 | 70 | 2020 |
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies C Liu, RS Bhangoo, TT Sio, NY Yu, J Shan, JS Chiang, JX Ding, WG Rule, ... Journal of applied clinical medical physics 20 (7), 15-27, 2019 | 56 | 2019 |
Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint J Shan, Y An, M Bues, SE Schild, W Liu Medical physics 45 (1), 460-469, 2018 | 53 | 2018 |
Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy W Deng, JE Younkin, K Souris, S Huang, K Augustine, M Fatyga, X Ding, ... Medical physics 47 (6), 2558-2574, 2020 | 51 | 2020 |
Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: a dosimetric comparative study C Liu, TT Sio, W Deng, J Shan, TB Daniels, WG Rule, PR Lara, SM Korte, ... Journal of applied clinical medical physics 19 (6), 140-148, 2018 | 50 | 2018 |
Intensity‐modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non‐small cell lung … J Shan, Y Yang, SE Schild, TB Daniels, WW Wong, M Fatyga, M Bues, ... Medical physics 47 (11), 5428-5440, 2020 | 36 | 2020 |
Treatment planning system (TPS) approximations matter—comparing intensity‐modulated proton therapy (IMPT) plan quality and robustness between a commercial and an in‐house … C Liu, NY Yu, J Shan, RS Bhangoo, TB Daniels, JS Chiang, X Ding, ... Medical physics 46 (11), 4755-4762, 2019 | 28 | 2019 |
Early outcomes of patients with locally advanced non-small cell lung cancer treated with intensity-modulated proton therapy versus intensity-modulated radiation therapy: the … YY Nathan, TA DeWees, C Liu, TB Daniels, JB Ashman, SE Beamer, ... Advances in Radiation Oncology 5 (3), 450-458, 2020 | 27 | 2020 |
4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma H Feng, J Shan, JB Ashman, WG Rule, RS Bhangoo, NY Yu, J Chiang, ... Medical physics 48 (8), 4636-4647, 2021 | 25 | 2021 |
A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity‐modulated proton radiotherapy J Shan, TT Sio, C Liu, SE Schild, M Bues, W Liu Medical physics 46 (1), 382-393, 2019 | 25 | 2019 |
Per‐voxel constraints to minimize hot spots in linear energy transfer‐guided robust optimization for base of skull head and neck cancer patients in IMPT H Feng, J Shan, JD Anderson, WW Wong, SE Schild, RL Foote, ... Medical physics 49 (1), 632-647, 2022 | 23 | 2022 |
Clinical validation of a ray-casting analytical dose engine for spot scanning proton delivery systems JE Younkin, DH Morales, J Shen, J Shan, M Bues, JM Lentz, SE Schild, ... Technology in Cancer Research & Treatment 18, 1533033819887182, 2019 | 21 | 2019 |
Automation of routine elements for spot‐scanning proton patient‐specific quality assurance D Hernandez Morales, J Shan, W Liu, KE Augustine, M Bues, MJ Davis, ... Medical physics 46 (1), 5-14, 2019 | 18 | 2019 |
Virtual particle Monte Carlo: A new concept to avoid simulating secondary particles in proton therapy dose calculation J Shan, H Feng, DH Morales, SH Patel, WW Wong, M Fatyga, M Bues, ... Medical physics 49 (10), 6666-6683, 2022 | 16 | 2022 |
Mixed integer programming with dose‐volume constraints in intensity‐modulated proton therapy P Zhang, N Fan, J Shan, SE Schild, M Bues, W Liu Journal of applied clinical medical physics 18 (5), 29-35, 2017 | 15 | 2017 |
Evaluation and second check of a commercial Monte Carlo dose engine for small‐field apertures in pencil beam scanning proton therapy J Holmes, J Shen, J Shan, CL Patrick, WW Wong, RL Foote, SH Patel, ... Medical physics 49 (5), 3497-3506, 2022 | 13 | 2022 |
System and Method for Robust Treatment Planning in Radiation Therapy W Liu, J Shan US Patent App. 17/271,751, 2021 | 1 | 2021 |
A method for quantitative evaluations of scanning‐proton dose distributions BC Allred, J Shan, DG Robertson, TA DeWees, J Shen, W Liu, JB Stoker Journal of applied clinical medical physics 22 (4), 193-201, 2021 | 1 | 2021 |
Virtual Particle Based Monte Carlo Dose Calculation for Charged Particle Therapy Treatment Planning W Liu, J Shan US Patent App. 17/832,122, 2023 | | 2023 |