A review of tactile sensing technologies with applications in biomedical engineering MI Tiwana, SJ Redmond, NH Lovell Sensors and Actuators A: physical 179, 17-31, 2012 | 845 | 2012 |
A method for initialising the K-means clustering algorithm using kd-trees SJ Redmond, C Heneghan Pattern recognition letters 28 (8), 965-973, 2007 | 430 | 2007 |
Barometric pressure and triaxial accelerometry-based falls event detection F Bianchi, SJ Redmond, MR Narayanan, S Cerutti, NH Lovell IEEE Transactions on Neural Systems and Rehabilitation Engineering 18 (6 …, 2010 | 377 | 2010 |
Sensors-based wearable systems for monitoring of human movement and falls T Shany, SJ Redmond, MR Narayanan, NH Lovell IEEE Sensors journal 12 (3), 658-670, 2011 | 372 | 2011 |
Cardiorespiratory-based sleep staging in subjects with obstructive sleep apnea SJ Redmond, C Heneghan IEEE Transactions on Biomedical Engineering 53 (3), 485-496, 2006 | 284 | 2006 |
Tracking the evolution of smartphone sensing for monitoring human movement MB Del Rosario, SJ Redmond, NH Lovell Sensors 15 (8), 18901-18933, 2015 | 263 | 2015 |
Tactile sensors for friction estimation and incipient slip detection—Toward dexterous robotic manipulation: A review W Chen, H Khamis, I Birznieks, NF Lepora, SJ Redmond IEEE Sensors Journal 18 (22), 9049-9064, 2018 | 199 | 2018 |
Signal quality measures for pulse oximetry through waveform morphology analysis JA Sukor, SJ Redmond, NH Lovell Physiological measurement 32 (3), 369, 2011 | 178 | 2011 |
Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different MAD Brodie, MJM Coppens, SR Lord, NH Lovell, YJ Gschwind, ... Medical & biological engineering & computing 54, 663-674, 2016 | 162 | 2016 |
Sleep staging using cardiorespiratory signals. SJ Redmond, P De Chazal, C O'Brien, S Ryan, WT McNicholas, ... Somnologie 11 (4), 2007 | 130 | 2007 |
Longitudinal falls-risk estimation using triaxial accelerometry MR Narayanan, SJ Redmond, ME Scalzi, SR Lord, BG Celler, NH Lovell IEEE Transactions on Biomedical Engineering 57 (3), 534-541, 2009 | 121 | 2009 |
Predicting the risk of exacerbation in patients with chronic obstructive pulmonary disease using home telehealth measurement data MS Mohktar, SJ Redmond, NC Antoniades, PD Rochford, JJ Pretto, ... Artificial intelligence in medicine 63 (1), 51-59, 2015 | 120 | 2015 |
QRS detection algorithm for telehealth electrocardiogram recordings H Khamis, R Weiss, Y Xie, CW Chang, NH Lovell, SJ Redmond IEEE Transactions on Biomedical Engineering 63 (7), 1377-1388, 2016 | 106 | 2016 |
Encoding of tangential torque in responses of tactile afferent fibres innervating the fingerpad of the monkey I Birznieks, HE Wheat, SJ Redmond, LM Salo, NH Lovell, AW Goodwin The Journal of physiology 588 (7), 1057-1072, 2010 | 104 | 2010 |
Electrocardiogram signal quality measures for unsupervised telehealth environments SJ Redmond, Y Xie, D Chang, J Basilakis, NH Lovell Physiological Measurement 33 (9), 1517, 2012 | 99 | 2012 |
Towards using photo-plethysmogram amplitude to measure blood pressure during sleep ECP Chua, SJ Redmond, G McDarby, C Heneghan Annals of biomedical engineering 38, 945-954, 2010 | 98 | 2010 |
Design of a decision-support architecture for management of remotely monitored patients J Basilakis, NH Lovell, SJ Redmond, BG Celler ieee transactions on information technology in biomedicine 14 (5), 1216-1226, 2010 | 94 | 2010 |
Characterization of a capacitive tactile shear sensor for application in robotic and upper limb prostheses MI Tiwana, A Shashank, SJ Redmond, NH Lovell Sensors and Actuators A: physical 165 (2), 164-172, 2011 | 91 | 2011 |
Quaternion-based complementary filter for attitude determination of a smartphone MB Del Rosario, NH Lovell, SJ Redmond IEEE Sensors Journal 16 (15), 6008-6017, 2016 | 89 | 2016 |
A comparison of activity classification in younger and older cohorts using a smartphone MB Del Rosario, K Wang, J Wang, Y Liu, M Brodie, K Delbaere, NH Lovell, ... Physiological measurement 35 (11), 2269, 2014 | 84 | 2014 |