Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living WCC Lee, LA Frossard, K Hagberg, E Haggstrom, R Brånemark, ... Clinical biomechanics 22 (6), 665-673, 2007 | 197 | 2007 |
Functional outcome of transfemoral amputees fitted with an osseointegrated fixation: temporal gait characteristics L Frossard, K Hagberg, E Häggström, DL Gow, R Brånemark, M Pearcy JPO: Journal of Prosthetics and Orthotics 22 (1), 11-20, 2010 | 195 | 2010 |
Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking WCC Lee, LA Frossard, K Hagberg, E Haggstrom, DL Gow, S Gray, ... Medical Engineering & Physics 30 (7), 825-833, 2008 | 183 | 2008 |
Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living L Frossard, J Beck, M Dillon, J Evans JPO: Journal of Prosthetics and Orthotics 15 (4), 135-142, 2003 | 157 | 2003 |
Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: a tool for evidence-based practice L Frossard, N Stevenson, J Smeathers, E Häggström, K Hagberg, ... Prosthetics and orthotics international 32 (1), 68-78, 2008 | 154 | 2008 |
Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements R Dumas, L Cheze, L Frossard Gait & posture 30 (4), 560-562, 2009 | 148 | 2009 |
Load on osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis LA Frossard, R Tranberg, E Haggstrom, M Pearcy, R Brånemark Prosthetics and orthotics international 34 (1), 85-97, 2010 | 143 | 2010 |
Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study L Frossard, DL Gow, K Hagberg, N Cairns, B Contoyannis, S Gray, ... Gait & posture 31 (2), 223-228, 2010 | 119 | 2010 |
Load-relief of walking aids on osseointegrated fixation: instrument for evidence-based practice L Frossard, K Hagberg, E Haggstrom, R Branemark IEEE Transactions on Neural Systems and Rehabilitation Engineering 17 (1), 9-14, 2008 | 115 | 2008 |
Categorization of activities of daily living of lower limb amputees during short-term use of a portable kinetic recording system: A preliminary study L Frossard, N Stevenson, J Sullivan, M Uden, M Pearcy JPO: Journal of Prosthetics and Orthotics 23 (1), 2-11, 2011 | 107 | 2011 |
Risk of failure during gait for direct skeletal attachment of a femoral prosthesis: a finite element study B Helgason, H Pálsson, TP Rúnarsson, L Frossard, M Viceconti Medical engineering & physics 31 (5), 595-600, 2009 | 105 | 2009 |
Static load bearing exercises of individuals with transfemoral amputation fitted with an osseointegrated implant: reliability of kinetic data S Vertriest, P Coorevits, K Hagberg, R Brånemark, E Häggström, ... IEEE Transactions on Neural Systems and Rehabilitation Engineering 23 (3 …, 2014 | 98* | 2014 |
Dynamic input to determine hip joint moments, power and work on the prosthetic limb of transfemoral amputees: ground reaction vs knee reaction L Frossard, L Cheze, R Dumas Prosthetics and Orthotics International 35 (2), 140-149, 2011 | 97 | 2011 |
FE stress analysis of the interface between the bone and an osseointegrated implant for amputees–implications to refine the rehabilitation program WCC Lee, JM Doocey, R Brånemark, CJ Adam, JH Evans, MJ Pearcy, ... Clinical biomechanics 23 (10), 1243-1250, 2008 | 92 | 2008 |
Load on osseointegrated fixation of a transfemoral amputee during a fall: Determination of the time and duration of descent LA Frossard Prosthetics and orthotics international 34 (4), 472-487, 2010 | 89 | 2010 |
Fall of a transfemoral amputee fitted with osseointegrated fixation: loading impact on residuum LA Frossard, R Tranberg, E Haggstrom, MJ Pearcy, R Brånemark 18th Annual General Meeting of European Society of Movement Analysis in …, 2009 | 89 | 2009 |
Daily activities of a transfemoral amputee fitted with osseointegrated fixation: continuous recording of the loading for an evidence-based practice L Frossard, N Stevenson, J Smeathers, DL Gow, S Gray, J Sullivan, ... Kinesitherapie Revue 6 (56-57), 53-62, 2006 | 66 | 2006 |
Gait analysis of transfemoral amputees: errors in inverse dynamics are substantial and depend on prosthetic design R Dumas, R Brånemark, L Frossard IEEE transactions on neural systems and rehabilitation engineering 25 (6 …, 2016 | 61 | 2016 |
Load applied on bone-anchored transfemoral prosthesis: characterization of a prosthesis-a pilot study L Frossard, E Haggstrom, K Hagberg, R Branemark Journal of rehabilitation research and development 50 (5), 619-634, 2013 | 56 | 2013 |
Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases A Khemka, L Frossard, SJ Lord, B Bosley, M Al Muderis Acta orthopaedica 86 (6), 740-744, 2015 | 55 | 2015 |