Systematic distortions in magnetic position digitizers W Birkfellner, F Watzinger, F Wanschitz, G Enislidis, C Kollmann, D Rafolt, ... Medical physics 25 (11), 2242-2248, 1998 | 176 | 1998 |
Modulation of motor cortex excitability by different levels of whole-hand afferent electrical stimulation SM Golaszewski, J Bergmann, M Christova, AB Kunz, M Kronbichler, ... Clinical Neurophysiology 123 (1), 193-199, 2012 | 82 | 2012 |
Modulation of sensorimotor cortex by repetitive peripheral magnetic stimulation E Gallasch, M Christova, A Kunz, D Rafolt, S Golaszewski Frontiers in human neuroscience 9, 407, 2015 | 80 | 2015 |
Basic design and construction of the Vienna FES implants: existing solutions and prospects for new generations of implants W Mayr, M Bijak, D Rafolt, S Sauermann, E Unger, H Lanmüller Medical engineering & physics 23 (1), 53-60, 2001 | 69 | 2001 |
Functional Electrical Stimulation (FES) of denervated muscles: existing and prospective technological solutions W Mayr, C Hofer, M Bijak, D Rafolt, E Unger, M Reichel, S Sauermann, ... Basic Appl Myol 12 (6), 287-290, 2002 | 65 | 2002 |
Changes in motor cortex excitability following training of a novel goal-directed motor task E Gallasch, M Christova, M Krenn, A Kossev, D Rafolt European journal of applied physiology 105, 47-54, 2009 | 64 | 2009 |
Cumulative effects of anodal and priming cathodal tDCS on pegboard test performance and motor cortical excitability M Christova, D Rafolt, E Gallasch Behavioural brain research 287, 27-33, 2015 | 62 | 2015 |
Mobile gait analysis via eSHOEs instrumented shoe insoles: a pilot study for validation against the gold standard GAITRite® H Jagos, K Pils, M Haller, C Wassermann, C Chhatwal, D Rafolt, F Rattay Journal of medical engineering & technology 41 (5), 375-386, 2017 | 60 | 2017 |
Outlasting corticomotor excitability changes induced by 25 Hz whole-hand mechanical stimulation M Christova, D Rafolt, S Golaszewski, E Gallasch European Journal of Applied Physiology 111, 3051-3059, 2011 | 52 | 2011 |
Increased motor cortical excitability after whole-hand electrical stimulation: a TMS study SM Golaszewski, J Bergmann, M Christova, R Nardone, M Kronbichler, ... Clinical Neurophysiology 121 (2), 248-254, 2010 | 48 | 2010 |
Development of the Varioscope AR. A see-through HMD for computer-aided surgery W Birkfellner, K Huber, F Watzinger, M Figl, F Wanschitz, R Hanel, ... Proceedings IEEE and ACM International Symposium on Augmented Reality (ISAR …, 2000 | 45 | 2000 |
A framework for (tele-) monitoring of the rehabilitation progress in stroke patients H Jagos, V David, M Haller, S Kotzian, M Hofmann, S Schlossarek, ... Applied Clinical Informatics 6 (04), 757-768, 2015 | 36 | 2015 |
The Varioscope AR–A head-mounted operating microscope for Augmented Reality W Birkfellner, M Figl, K Huber, F Watzinger, F Wanschitz, R Hanel, ... Medical Image Computing and Computer-Assisted Intervention–MICCAI 2000 …, 2000 | 35 | 2000 |
MYOSTIM‐FES to prevent muscle atrophy in microgravity and bed rest: preliminary report W Mayr, M Bijak, W Girsch, C Hofer, H Lanmüller, D Rafolt, M Rakos, ... Artificial organs 23 (5), 428-431, 1999 | 35 | 1999 |
Vibration stimulation during non-fatiguing tonic contraction induces outlasting neuroplastic effects M Christova, D Rafolt, W Mayr, B Wilfling, E Gallasch Journal of Electromyography and Kinesiology 20 (4), 627-635, 2010 | 34 | 2010 |
Instrumentation for assessment of tremor, skin vibrations, and cardiovascular variables in MIR space missions E Gallasch, D Rafolt, M Moser, J Hindinger, H Eder, G Wießpeiner, ... IEEE transactions on biomedical engineering 43 (3), 328-333, 1996 | 33 | 1996 |
One minute static stretch of plantar flexors transiently increases H reflex excitability and exerts no effect on corticospinal pathways F Budini, E Gallasch, M Christova, D Rafolt, AB Rauscher, M Tilp Experimental Physiology 102 (8), 901-910, 2017 | 32 | 2017 |
Cuff-type pneumatic stimulator for studying somatosensory evoked responses with fMRI E Gallasch, M Fend, D Rafolt, R Nardone, A Kunz, M Kronbichler, ... NeuroImage 50 (3), 1067-1073, 2010 | 29 | 2010 |
Influence of Contact Forces on Wrist Photo plethysmography–Prestudy for a Wearable Patient Monitor/Einfluß von Kontaktkräften auf die photoplethysmografische Pulsmessung am … D Rafolt, E Gallasch Walter de Gruyter 49 (1-2), 22-26, 2004 | 29 | 2004 |
The Vienna functional electrical stimulation system for restoration of walking functions in spastic paraplegia M Bijak, W Mayr, M Rakos, C Hofer, H Lanmüller, D Rafolt, M Reichel, ... Artificial organs 26 (3), 224-227, 2002 | 26 | 2002 |