Pulseq: a rapid and hardware‐independent pulse sequence prototyping framework KJ Layton, S Kroboth, F Jia, S Littin, H Yu, J Leupold, JF Nielsen, ... Magnetic resonance in medicine 77 (4), 1544-1552, 2017 | 209 | 2017 |
Development and implementation of an 84‐channel matrix gradient coil S Littin, F Jia, KJ Layton, S Kroboth, H Yu, J Hennig, M Zaitsev Magnetic resonance in medicine 79 (2), 1181-1191, 2018 | 73 | 2018 |
Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development KS Ravi, S Potdar, P Poojar, AK Reddy, S Kroboth, JF Nielsen, M Zaitsev, ... Magnetic resonance imaging 52, 9-15, 2018 | 45 | 2018 |
Design of a shielded coil element of a matrix gradient coil F Jia, S Littin, KJ Layton, S Kroboth, H Yu, M Zaitsev Journal of Magnetic Resonance 281, 217-228, 2017 | 43 | 2017 |
Design of a shim coil array matched to the human brain anatomy F Jia, H Elshatlawy, A Aghaeifar, YH Chu, YC Hsu, S Littin, S Kroboth, ... Magnetic resonance in medicine 83 (4), 1442-1457, 2020 | 21 | 2020 |
Trajectory optimization based on the signal‐to‐noise ratio for spatial encoding with nonlinear encoding fields KJ Layton, S Kroboth, F Jia, S Littin, H Yu, M Zaitsev Magnetic Resonance in Medicine 76 (1), 104-117, 2016 | 20 | 2016 |
Optimization of coil element configurations for a matrix gradient coil S Kroboth, KJ Layton, F Jia, S Littin, H Yu, J Hennig, M Zaitsev IEEE transactions on medical imaging 37 (1), 284-292, 2017 | 18 | 2017 |
Optimization of matrix gradient coil switching for a limited number of amplifiers S Kroboth, KJ Layton, F Jia, S Littin, H Yu, M Zaitsev Proceedings of ISMRM. ISMRM. Toronto, 2015 | 8 | 2015 |
Open Source Imaging Initiative (OSI²)–Update and Roadmap F Arndt, S Aussenhofer, E Behrens, C Blücher, P Blümler, J Brand, ... Proc Intl Soc Mag Reson Med 193, 2017 | 7 | 2017 |
Switching circuit optimization for matrix gradient coils S Kroboth, KJ Layton, F Jia, S Littin, H Yu, J Hennig, M Zaitsev Tomography 5 (2), 248, 2019 | 6 | 2019 |
Shielded matrix gradient coil S Littin, F Jia, S Kroboth, KJ Layton, H Yu, M Zaitsev Proc Int Soc Magn Res Med 23, 1022, 2015 | 6 | 2015 |
An improved design of multi-channel switching circuit for matrix gradient coil H Yu, F Huethe, S Littin, KJ Layton, S Kroboth, F Jia, J Hennig, M Zaitsev Proceedings of ISMRM. ISMRM. Toronto, 2015 | 6 | 2015 |
Optimization of a switching circuit for a matrix gradient coil S Kroboth, KJ Layton, F Jia, S Littin, H Yu, J Hennig, M Zaitsev Proceedings of the 24th Annual Meeting of ISMRM, Singapore 2208, 2016 | 5 | 2016 |
A multichannel gradient driver system for matrix gradient coils H Yu, K Layton, S Littin, S Kroboth, F Jia, M Zaitsev Proceedings of the 24th Annual Meeting of ISMRM, Singapore, 2016 | 5 | 2016 |
A hardware-independent environment for MR acquisition and simulation K Layton, S Kroboth, J Leupold, H Yu, F Jia, S Littin, T Stcker, M Zaitsev Proc Intl Soc Magn Reson Med, 2484, 2015 | 5 | 2015 |
Transparent integration of opportunistic resources into the WLCG compute infrastructure M Böhler, R Caspart, M Fischer, O Freyermuth, M Giffels, S Kroboth, ... EPJ Web of Conferences 251, 02039, 2021 | 4 | 2021 |
Radial MRI with variable echo times: reducing the orientation dependency of susceptibility artifacts of an MR-safe guidewire KE Schleicher, M Bock, K Düring, S Kroboth, AJ Krafft Magnetic Resonance Materials in Physics, Biology and Medicine 31, 235-242, 2018 | 4 | 2018 |
Image reconstruction of single-shot north west EPI data acquired with PatLoc gradients using magnetic field monitoring and total generalized variation conjugate gradient S Kroboth, F Testud, K Bredies, KJ Layton, D Gallichan, CA Cocosco, ... Proceedings of the 21st Annual Meeting of ISMRM, 3827, 2013 | 4 | 2013 |
Spiral RARE with annular segmentation J Hennig, M Menza, A Barghoorn, B Riemenschneider, S Kroboth, ... Proc Intl Soc Magn Reson Med 27, 4632, 2019 | 3 | 2019 |
Imaging with a high-channel matrix gradient coil KJ Layton, H Yu, S Kroboth, S Littin, F Jia, M Zaitsev Proc. ISMRM, # 3550, 2016 | 3 | 2016 |