Fluid–structure interaction modeling in cardiovascular medicine–A systematic review 2017–2019 M Hirschhorn, V Tchantchaleishvili, R Stevens, J Rossano, ... Medical engineering & physics 78, 1-13, 2020 | 107 | 2020 |
Technology landscape of pediatric mechanical circulatory support devices: A systematic review 2010–2021 T Palazzolo, M Hirschhorn, E Garven, S Day, RM Stevens, J Rossano, ... Artificial organs 46 (8), 1475-1490, 2022 | 11 | 2022 |
A cross university-led COVID-19 rapid-response effort: design, build, and distribute drexel AJFlex face shields AL Throckmorton, EJ Bass, B Ferrick, A Ramakrishnan, S Eichmann, ... Annals of biomedical engineering 49, 950-958, 2021 | 8 | 2021 |
Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments M Hirschhorn, N Catucci, SW Day, RM Stevens, V Tchantchaleishvili, ... Artificial organs 47 (4), 680-694, 2023 | 6 | 2023 |
Development of the centrifugal blood pump for a hybrid continuous flow pediatric total artificial heart: Model, make, measure CS Fox, T Palazzolo, M Hirschhorn, RM Stevens, J Rossano, SW Day, ... Frontiers in cardiovascular medicine 9, 886874, 2022 | 6 | 2022 |
Fluid‐structure interaction analysis of a collapsible axial flow blood pump impeller and protective cage for Fontan patients M Hirschhorn, E Bisirri, R Stevens, AL Throckmorton Artificial organs 44 (8), E337-E347, 2020 | 6 | 2020 |
Forward-thinking design solutions for mechanical circulatory support: multifunctional hybrid continuous-flow ventricular assist device technology A Throckmorton, E Garven, M Hirschhorn, S Day, R Stevens, ... Annals of cardiothoracic surgery 10 (3), 383, 2021 | 4 | 2021 |
Next generation development of hybrid continuous flow pediatric total artificial heart technology: Design–build–test MD Hirschhorn, JEM Lawley, AJ Roof, APT Johnson, WA Stoddard, ... ASAIO Journal 69 (12), 1090-1098, 2023 | 2 | 2023 |
BIO27: advancements of DragonHeart BiVentricular assist device WA Stoddard, MD Hirschhorn, APT Johnson, AJ Roof, JE Lawley, ... ASAIO Journal 68 (Supplement 2), 24, 2022 | 1 | 2022 |
Pediatric mechanical circulatory support-leveraging design innovation for the younger generation M Hirschhorn, A Throckmorton Journal of cardiac surgery 35 (1), 8-10, 2020 | 1 | 2020 |
Fluid-structure interaction analysis of implantable axial flow blood pump impeller for Fontan patients MD Hirschhorn Drexel University, 2018 | 1 | 2018 |
P26: Development of Hybrid Continuous Flow Pediatric TAH Technology J Lawley, M Hirschhorn, A Johnson, A Roof, V Tchantchaleishvili, S Day, ... ASAIO journal 69 (Supplement 2), 119-120, 2023 | | 2023 |
P76: Need for an Interlaboratory Study of Mock Circulatory Loops to Evaluate the Performance of Mechanical Circulatory Support Devices M Hirschhorn, G D’Souza, E Richardson, A Crusan, J Rinaldi, ... ASAIO Journal 69 (Supplement 2), 153, 2023 | | 2023 |
Novel Integrated Pediatric Total Artificial Heart MD Hirschhorn Drexel University, 2022 | | 2022 |
The newly emerging field of pediatric engineering: Innovation for our next generation M Hirschhorn, EE Garven, JL Wells, R Stevens, V Tchantchaleishvili, ... Artificial organs 45 (6), 537-541, 2021 | | 2021 |