关注
Wook-Geun Shin
Wook-Geun Shin
Massachusetts General Hospital
在 mgh.harvard.edu 的电子邮件经过验证
标题
引用次数
引用次数
年份
Geant4‐DNA example applications for track structure simulations in liquid water: a report from the Geant4‐DNA Project
S Incerti, I Kyriakou, MA Bernal, MC Bordage, Z Francis, S Guatelli, ...
Medical physics 45 (8), e722-e739, 2018
3112018
Evaluation of early radiation DNA damage in a fractal cell nucleus model using Geant4-DNA
D Sakata, N Lampe, M Karamitros, I Kyriakou, O Belov, MA Bernal, ...
Physica Medica 62, 152-157, 2019
652019
Fully integrated Monte Carlo simulation for evaluating radiation induced DNA damage and subsequent repair using Geant4-DNA
D Sakata, O Belov, MC Bordage, D Emfietzoglou, S Guatelli, T Inaniwa, ...
Scientific reports 10 (1), 20788, 2020
432020
Review of the Geant4-DNA simulation toolkit for radiobiological applications at the cellular and DNA level
I Kyriakou, D Sakata, HN Tran, Y Perrot, WG Shin, N Lampe, S Zein, ...
Cancers 14 (1), 35, 2021
392021
Evaluation of the influence of physical and chemical parameters on water radiolysis simulations under MeV electron irradiation using Geant4-DNA
WG Shin, J Ramos-Mendez, B Faddegon, HN Tran, C Villagrasa, Y Perrot, ...
Journal of Applied Physics 126 (11), 2019
392019
Independent reaction times method in Geant4‐DNA: Implementation and performance
J Ramos‐Méndez, WG Shin, M Karamitros, J Domínguez‐Kondo, ...
Medical physics 47 (11), 5919-5930, 2020
292020
Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea
WG Shin, M Testa, HS Kim, JH Jeong, SB Lee, YJ Kim, CH Min
Physics in Medicine & Biology 62 (19), 7598, 2017
282017
Validation of energy-weighted algorithm for radiation portal monitor using plastic scintillator
HC Lee, WG Shin, HJ Park, DH Yoo, CI Choi, CS Park, HS Kim, CH Min
Applied Radiation and Isotopes 107, 160-164, 2016
242016
Assessment of radio-induced damage in endothelial cells irradiated with 40 kVp, 220 kVp, and 4 MV X-rays by means of micro and nanodosimetric calculations
N Tang, M Bueno, S Meylan, Y Perrot, HN Tran, A Freneau, M Dos Santos, ...
International journal of molecular sciences 20 (24), 6204, 2019
232019
Development of a new Geant4-DNA electron elastic scattering model for liquid-phase water using the ELSEPA code
WG Shin, MC Bordage, D Emfietzoglou, I Kyriakou, D Sakata, CH Min, ...
Journal of Applied Physics 124 (22), 2018
232018
Geant4-DNA simulation of the pre-chemical stage of water radiolysis and its impact on initial radiochemical yields
WG Shin, J Ramos-Mendez, NH Tran, S Okada, Y Perrot, C Villagrasa, ...
Physica Medica 88, 86-90, 2021
222021
A Monte Carlo study of an energy-weighted algorithm for radionuclide analysis with a plastic scintillation detector
WG Shin, HC Lee, CI Choi, CS Park, HS Kim, CH Min
Applied Radiation and Isotopes 101, 53-59, 2015
202015
Electron transport in DNA bases: An extension of the Geant4-DNA Monte Carlo toolkit
SA Zein, MC Bordage, Z Francis, G Macetti, A Genoni, C Dal Cappello, ...
Nuclear Instruments and Methods in Physics Research Section B: Beam …, 2021
182021
TOPAS-nBio validation for simulating water radiolysis and DNA damage under low-LET irradiation
J Ramos-Méndez, JA LaVerne, N Domínguez-Kondo, J Milligan, ...
Physics in Medicine & Biology 66 (17), 175026, 2021
172021
Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms
HC Lee, DH Yoo, M Testa, WG Shin, HJ Choi, WH Ha, J Yoo, S Yoon, ...
Applied Radiation and Isotopes 110, 230-235, 2016
162016
A Geant4-DNA evaluation of radiation-induced DNA damage on a human fibroblast
WG Shin, D Sakata, N Lampe, O Belov, NH Tran, I Petrovic, A Ristic-Fira, ...
Cancers 13 (19), 4940, 2021
132021
Assessment of DNA damage with an adapted independent reaction time approach implemented in Geant4‐DNA for the simulation of diffusion‐controlled reactions between radio‐induced …
HN Tran, J Ramos‐Méndez, W Shin, Y Perrot, B Faddegon, S Okada, ...
Medical physics 48 (2), 890-901, 2021
112021
Radioisotope identification using an energy-weighted algorithm with a proof-of-principle radiation portal monitor based on plastic scintillators
HC Lee, W Shin, HJ Choi, CI Choi, CS Park, HS Kim, CH Min
Applied Radiation and Isotopes 156, 109010, 2020
112020
An effective dose assessment technique with NORM added consumer products using skin-point source on computational human phantom
DH Yoo, WG Shin, HC Lee, HJ Choi, M Testa, JK Lee, YS Yeom, CH Kim, ...
Applied Radiation and Isotopes 118, 56-61, 2016
102016
Feasibility study for the assessment of the exposed dose with TENORM added in consumer products
DH Yoo, HC Lee, WG Shin, WH Ha, JR Yoo, SW Yoon, J Lee, WC Choi, ...
Radiation protection dosimetry 167 (1-3), 255-259, 2015
102015
系统目前无法执行此操作,请稍后再试。
文章 1–20