Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method FA Dilmanian, Z Zhong, B Ren, XY Wu, LD Chapman, I Orion, ... Physics in Medicine & Biology 45 (4), 933, 2000 | 356 | 2000 |
A mathematical model for tumor volume evaluation using two-dimensions JP Feldman, R Goldwasser, S Mark, J Schwartz, I Orion J appl quant methods 4 (4), 455-462, 2009 | 163 | 2009 |
Response of avian embryonic brain to spatially segmented x-ray microbeams. FA Dilmanian, GM Morris, G Le Duc, X Huang, B Ren, T Bacarian, ... Cellular and molecular biology (Noisy-le-Grand, France) 47 (3), 485-493, 2001 | 141 | 2001 |
The performance of a novel ion-counting nanodosimeter G Garty, S Shchemelinin, A Breskin, R Chechik, G Assaf, I Orion, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002 | 111 | 2002 |
Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system4 I Orion, AB Rosenfeld, FA Dilmanian, F Telang, B Ren, Y Namito Physics in Medicine & Biology 45 (9), 2497, 2000 | 85 | 2000 |
Method and apparatus for thrombus dissolution/thrombectomy by an electrode catheter device I Orion US Patent 10,028,782, 2018 | 83 | 2018 |
Soil carbon measurements using inelastic neutron scattering L Wielopolski, I Orion, G Hendrey, H Roger IEEE Transactions on Nuclear Science 47 (3), 914-917, 2000 | 68 | 2000 |
MOSFET dosimetry of an X-ray microbeam AB Rosenfeld, GI Kaplan, T Kron, BJ Allen, A Dilmanian, I Orion, B Ren, ... IEEE Transactions on Nuclear Science 46 (6), 1774-1780, 1999 | 62 | 1999 |
Basic considerations for Monte Carlo calculations in soil L Wielopolski, Z Song, I Orion, AL Hanson, G Hendrey Applied radiation and isotopes 62 (1), 97-107, 2005 | 51 | 2005 |
Optimization of 6LiF: ZnS (Ag) scintillator light yield using GEANT4 Y Yehuda-Zada, K Pritchard, JB Ziegler, C Cooksey, K Siebein, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2018 | 32 | 2018 |
Wall-less ion-counting nanodosimetry applied to protons G Garty, S Shchemelinin, A Breskin, R Chechik, I Orion, G P. Guedes, ... Radiation protection dosimetry 99 (1-4), 325-330, 2002 | 32 | 2002 |
The dependence of the virtual point-detector on the HPGe detector dimensions S Mahling, I Orion, ZB Alfassi Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2006 | 30 | 2006 |
Dosimetric characterization of Elekta stereotactic cones E Borzov, A Nevelsky, R Bar‐Deroma, I Orion Journal of applied clinical medical physics 19 (1), 194-203, 2018 | 28 | 2018 |
Thermoluminescence characteristics of Israeli household salts for retrospective dosimetry in radiological events S Druzhyna, H Datz, YS Horowitz, L Oster, I Orion Nuclear Instruments and Methods in Physics Research Section B: Beam …, 2016 | 26 | 2016 |
Thrombectomy using both electrostatic and suction forces Y Taff, G Stern, I Orion US Patent App. 16/381,014, 2019 | 24 | 2019 |
Highly accurate prediction of specific activity using deep learning M Sheinfeld, S Levinson, I Orion Applied Radiation and Isotopes 130, 115-120, 2017 | 20 | 2017 |
Limitations in the PHOTON Monte Carlo gamma transport code I Orion, L Wielopolski Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002 | 20 | 2002 |
TVF-NMCRC—A powerful program for writing and executing simulation inputs for the FLUKA Monte Carlo code system S Mark, S Khomchenko, M Shifrin, Y Haviv, JR Schwartz, I Orion Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2007 | 19 | 2007 |
Nondestructive soil carbon analyzer (ND–SCA) L Wielopolski, S Mitra, G Hendrey, I Orion, S Prior, H Rogers, B Runion, ... BNL Report, 2004 | 19 | 2004 |
Design and dosimetry characteristics of a commercial applicator system for intra‐operative electron beam therapy utilizing ELEKTA Precise accelerator A Nevelsky, Z Bernstein, R Bar‐Deroma, A Kuten, I Orion Journal of applied clinical medical physics 11 (4), 57-69, 2010 | 17 | 2010 |