Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data K Shmueli, JA de Zwart, P van Gelderen, TQ Li, SJ Dodd, JH Duyn Magnetic Resonance in Medicine: An Official Journal of the International …, 2009 | 666 | 2009 |
Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal K Shmueli, P van Gelderen, JA de Zwart, SG Horovitz, M Fukunaga, ... Neuroimage 38 (2), 306-320, 2007 | 616 | 2007 |
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast M Fukunaga, TQ Li, P van Gelderen, JA de Zwart, K Shmueli, B Yao, ... Proceedings of the National Academy of Sciences 107 (8), 3834-3839, 2010 | 465 | 2010 |
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content B Yao, TQ Li, P van Gelderen, K Shmueli, JA de Zwart, JH Duyn Neuroimage 44 (4), 1259-1266, 2009 | 329 | 2009 |
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure J Lee, K Shmueli, M Fukunaga, P Van Gelderen, H Merkle, AC Silva, ... Proceedings of the National Academy of Sciences 107 (11), 5130-5135, 2010 | 299 | 2010 |
Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study M Bianciardi, M Fukunaga, P van Gelderen, SG Horovitz, JA de Zwart, ... Magnetic resonance imaging 27 (8), 1019-1029, 2009 | 278 | 2009 |
Quantitative susceptibility mapping: report from the 2016 reconstruction challenge C Langkammer, F Schweser, K Shmueli, C Kames, X Li, L Guo, C Milovic, ... Magnetic resonance in medicine 79 (3), 1661-1673, 2018 | 230 | 2018 |
The contribution of myelin to magnetic susceptibility-weighted contrasts in high-field MRI of the brain J Lee, K Shmueli, BT Kang, B Yao, M Fukunaga, P Van Gelderen, ... Neuroimage 59 (4), 3967-3975, 2012 | 230 | 2012 |
Optimal MRI methods for direct stereotactic targeting of the subthalamic nucleus and globus pallidus RL O’Gorman, K Shmueli, K Ashkan, M Samuel, DJ Lythgoe, A Shahidiani, ... European radiology 21, 130-136, 2011 | 98 | 2011 |
The contribution of chemical exchange to MRI frequency shifts in brain tissue K Shmueli, SJ Dodd, TQ Li, JH Duyn Magnetic Resonance in Medicine 65 (1), 35-43, 2011 | 97 | 2011 |
The effect of low resolution and coverage on the accuracy of susceptibility mapping A Karsa, S Punwani, K Shmueli Magnetic resonance in medicine 81 (3), 1833-1848, 2019 | 78 | 2019 |
Phase unwrapping with a rapid opensource minimum spanning tree algorithm (ROMEO) B Dymerska, K Eckstein, B Bachrata, B Siow, S Trattnig, K Shmueli, ... Magnetic resonance in medicine 85 (4), 2294-2308, 2021 | 77 | 2021 |
SEGUE: A speedy region-growing algorithm for unwrapping estimated phase A Karsa, K Shmueli IEEE transactions on medical imaging 38 (6), 1347-1357, 2018 | 76 | 2018 |
Tissue magnetic susceptibility mapping as a marker of tau pathology in Alzheimer's disease J O'callaghan, H Holmes, N Powell, JA Wells, O Ismail, IF Harrison, ... Neuroimage 159, 334-345, 2017 | 59 | 2017 |
High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging E De Vita, DL Thomas, S Roberts, HG Parkes, R Turner, P Kinchesh, ... The British journal of radiology 76 (909), 631-637, 2003 | 59 | 2003 |
Regional brain iron and gene expression provide insights into neurodegeneration in Parkinson’s disease GEC Thomas, A Zarkali, M Ryten, K Shmueli, AL Gil-Martinez, LA Leyland, ... Brain 144 (6), 1787-1798, 2021 | 57 | 2021 |
Design, construction and evaluation of an anthropomorphic head phantom with realistic susceptibility artifacts K Shmueli, DL Thomas, RJ Ordidge Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2007 | 44 | 2007 |
An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head‐and‐neck region A Karsa, S Punwani, K Shmueli Magnetic Resonance in Medicine 84 (6), 3206-3222, 2020 | 43 | 2020 |
PET/MRI attenuation estimation in the lung: a review of past, present, and potential techniques J Lillington, L Brusaferri, K Kläser, K Shmueli, R Neji, BF Hutton, F Fraioli, ... Medical physics 47 (2), 790-811, 2020 | 29 | 2020 |
Investigating the accuracy and precision of TE‐dependent versus multi‐echo QSM using Laplacian‐based methods at 3 T E Biondetti, A Karsa, DL Thomas, K Shmueli Magnetic resonance in medicine 84 (6), 3040-3053, 2020 | 25 | 2020 |