Numerical evaluation of influence of door opening on interzonal air exchange S Lee, B Park, T Kurabuchi Building and environment 102, 230-242, 2016 | 42 | 2016 |
Investigation of the energy saving efficiency of a natural ventilation strategy in a multistory school building B Park, S Lee Energies 13 (7), 1746, 2020 | 20 | 2020 |
Evaluation of heat transfer coefficients in various airconditioning modes by using thermal manikin S Lee, M Nogami, S Yamaguchi, T Kurabuchi, N Ohira | 17 | 2013 |
Influence of vane angle on the effectiveness of air conditioning of wall-mounted split-type air conditioners in residential buildings S Lee, J Lee, S Kato Science and Technology for the Built Environment 23 (5), 761-775, 2017 | 13 | 2017 |
Evaluation of thermal characteristics on a multi-sheet-type radiant panel heating system S Lee, B Park, J Kim, S Kato Journal of Building Engineering 8, 48-57, 2016 | 12 | 2016 |
FEASIBILITY STUDY OF IN SITU MEASUREMENT METHOD USING THE INFRARED CAMERA TO MEASURE U-VALUE OF WALLS ON RESIDENTIAL HOUSE INSTALLED AN CONVECTION STOVE Study on the thermal … S Lee, S Kato Journal of Environmental Engineering(Transaction of AIJ) 76 (661), 289-295, 2011 | 11 | 2011 |
Technical feasibility study of a compact desiccant-based outdoor air system using cogenerated hot water B Park, S Lee, S Kato Applied Thermal Engineering 106, 968-980, 2016 | 10 | 2016 |
Investigation on heat and mass transfer characteristics for a zeolite-coated heat exchanger using comparatively low-temperature energy: Heating humidification mode and cooling … B Park, S Lee Indoor and Built Environment 30 (9), 1486-1502, 2021 | 8 | 2021 |
Feasibility study of CFD prediction for evaluation of commercial kitchen environments T Kurabuchi, H Sosa, S Lee 13 th Conference of International Building Performance Simulation …, 2013 | 6 | 2013 |
Numerical investigation of the transmission route of infectious particles produced by human W Oh, R Ooka, H Kikumoto, S Lee CLIMA 2022 conference, 2022 | 5 | 2022 |
Performance comparison of conventional and local computer room air-conditioning systems in data centres by CFD analysis J Takeuchi, T Kurabuchi, H Yoshino, S Lee Indoor and Built Environment 26 (2), 238-247, 2017 | 5 | 2017 |
CFD Simulation on the indoor air quality in apartment housing equipped for total heat exchanger with air cleaning function JJ Yee, SH Lee, YK Kim, SK Park Journal of the Architectural Institute of Korea 21 (3), 157-164, 2005 | 5 | 2005 |
冬期における全館空調が導入された戸建住宅における送風ファンの可変風量制御が温熱環境に及ぼす効果に関する研究 岸卓也, 李時桓, 浅野良晴 日本建築学会環境系論文集 85 (767), 37-44, 2020 | 4 | 2020 |
窓サッシ部へのダイナミックインシュレーションの適用 実験棟を用いた実環境下における基本性能評価 樋山恭助, 河原大輔, 加藤信介, 李時桓, 大浦豊, 森勝彦, 野村吉和, ... 日本建築学会環境系論文集 79 (699), 435-441, 2014 | 4 | 2014 |
실험을 통한 열교환 환기장치 실험규격의 민감도 분석 이정재, 이시환, 박성관, 오상경 대한설비공학회 학술발표대회논문집, 38-38, 2004 | 4 | 2004 |
Numerical study on heat blocking efficiency of non-recirculating air curtain and its optimal discharge velocity S Lee E3S Web of Conferences 111, 03042, 2019 | 3 | 2019 |
戸建住宅の断熱改修における開口部サッシ部へのダイナミックインシュレーションの適用可能性検討 李時桓, 田中美穂, 加藤信介 日本建築学会環境系論文集 76 (669), 991-997, 2011 | 3 | 2011 |
住宅開口部サッシ部へのダイナミックインシュレーションの適用とその省エネルギー効果 田中美穂, 李時桓, 加藤信介 日本建築学会環境系論文集 76 (666), 689-696, 2011 | 3 | 2011 |
Dynamic Insulation System applied to Window Frames (Part 1)-Evaluation of the thermal insulation efficiency of the proposed window frames S Lee, M Tanaka, S Kato | 3 | 2010 |
Study on the feasibility of heat pump desiccant system combined with cogeneration system in heating and humidification mode B Park, S Lee, S Kato, Y Nam | 3 | 2010 |