ACA-Pro: calibration protocol for quantitative diffuse reflectance spectroscopy. Validation on contact and noncontact probe-and CCD-based systems
V Sorgato, M Berger, C Emain, C Vever-Bizet, JM Dinten, G Bourg-Heckly, ...
Journal of biomedical optics 21 (6), 065003-065003, 2016
132016
ROBUST CONTROL OF END-TIDAL CO₂ USING THE H∞ LOOP-SHAPING APPROACH
A Pomprapa, B Misgeld, V Sorgato, A Stollenwerk, M Walter, S Leonhardt
Acta Polytechnica 53 (6), 895-900, 2013
82013
Benchmarking the AlignRT surface deformation module for the early detection and quantification of oedema in breast cancer radiotherapy
V Sorgato, K Ghazouani, Y Queffelec, F Julia, S Clement, D Fric, J Farah
Technical Innovations & Patient Support in Radiation Oncology 21, 16-22, 2022
72022
Validation of optical properties quantification with a dual-step technique for biological tissue analysis
V Sorgato, M Berger, C Emain, C Vever-Bizet, JM Dinten, G Bourg-Heckly, ...
Journal of Biomedical Optics 23 (9), 096002-096002, 2018
62018
Non-contact quantitative diffuse reflectance spectroscopy
V Sorgato, M Berger, C Emain, A Koenig, B Roig, C Vever-Bizet, ...
European Conference on Biomedical Optics, 95380U, 2015
62015
Wide-field absolute quantification of absorption in turbid media
V Sorgato, M Berger, C Emain, C Vever-Bizet, JM Dinten, G Bourg-Heckly, ...
Optics and the Brain, JM3A. 32, 2016
32016
SurVolT: Surface to Volume conversion Tool. A proof of concept
A Gorecki, V Sorgato, C Mazzara, S Clément, D Fric, J Farah
Physica Medica 108, 102566, 2023
12023
Determining absorption and scattering coefficient using a calibrated optical reflectance signal
V Sorgato, A Planat-Chretien, M Berger
US Patent App. 15/737,600, 2018
12018
Quantitative 2D maps of optical properties reconstruction: pre-clinical results on rats
V Sorgato, M Berger, C Emain, C Vever-Bizet, G Bourg-Heckly, JM Dinten, ...
European Conference on Biomedical Optics, 104120P, 2017
12017
Benchmarking the AlignRT surface deformation module for the early detection and the quantification of oedema in breast cancer radiotherapy
V Sorgato, K Ghazouani, Y Queffelec, F Julia, S Clement, D Fric, J Farah
Physica Medica: European Journal of Medical Physics 92, S182, 2021
2021
TomoTherapy® System repositioning accuracy according to treatment localization
V Sorgato, P Chartier, JY Giraud
Physica Medica: European Journal of Medical Physics 67, 205, 2019
2019
Method and device for estimating optical properties of a sample
V Sorgato, M Berger, A Planat-Chretien, C Vever-Bizet, G Bourg-Heckly, ...
US Patent 10,107,745, 2018
2018
Diffuse Reflectance Spectral Imaging for the quantification of absorption and diffusion in homogeneous turbid media
V SORGATO, M BERGER, C EMAIN, A KOENIG, B ROIG, ...