Ventilation rates and health: multidisciplinary review of the scientific literature J Sundell, H Levin, WW Nazaroff, WS Cain, WJ Fisk, DT Grimsrud, ... Indoor air 21 (3), 191-204, 2011 | 863 | 2011 |
Evaluating building IAQ and ventilation with indoor carbon dioxide. AK Persily | 554 | 1997 |
Carbon dioxide generation rates for building occupants A Persily, L de Jonge Indoor air 27 (5), 868-879, 2017 | 507 | 2017 |
State-of-the-art review of CO2 demand controlled ventilation technology and application SJ Emmerich, AK Persily Diane Publishing, 2001 | 289 | 2001 |
Challenges in developing ventilation and indoor air quality standards: The story of ASHRAE Standard 62 A Persily Building and Environment 91, 61-69, 2015 | 267 | 2015 |
Contribution of gas and electric stoves to residential ultrafine particle concentrations between 2 and 64 nm: size distributions and emission and coagulation rates L Wallace, F Wang, C Howard-Reed, A Persily Environmental Science & Technology 42 (23), 8641-8647, 2008 | 205 | 2008 |
Modeled infiltration rate distributions for US housing A Persily, A Musser, SJ Emmerich Indoor air 20 (6), 473-485, 2010 | 162 | 2010 |
Field measurement of ventilation rates AK Persily Indoor Air 26 (1), 97-111, 2016 | 153 | 2016 |
Reduction of exposure to ultrafine particles by kitchen exhaust hoods: the effects of exhaust flow rates, particle size, and burner position D Rim, L Wallace, S Nabinger, A Persily Science of the Total Environment 432, 350-356, 2012 | 147 | 2012 |
Energy impacts of infiltration and ventilation in US office buildings using multizone airflow simulation AK Persily, SJ Emmerich Andrew K. Persily, Steven J. Emmerich, 1999 | 138 | 1999 |
Indoor air quality in sustainable, energy efficient buildings AK Persily, SJ Emmerich Hvac&R Research 18 (1-2), 4-20, 2012 | 124 | 2012 |
Literature review on CO2 based demand controlled ventilation. SJ Emmerich, A Persily | 113 | 1997 |
Impacts of airtightening retrofits on ventilation rates and energy consumption in a manufactured home S Nabinger, A Persily Energy and Buildings 43 (11), 3059-3067, 2011 | 108 | 2011 |
Infiltration of outdoor ultrafine particles into a test house P Rim, Wallace Environmental Science and Technology 44, 5908-5913, 2010 | 108 | 2010 |
Evolution of ultrafine particle size distributions following indoor episodic releases: relative importance of coagulation, deposition and ventilation D Rim, M Green, L Wallace, A Persily, JI Choi Aerosol Science and Technology 46 (5), 494-503, 2012 | 93 | 2012 |
Analysis of ventilation data from the US Environmental Protection Agency building assessment survey and evaluation (BASE) study AK Persily, J Gorfain US Department of Commerce, Technology Administration, National Institute of …, 2004 | 93 | 2004 |
A review of tracer gas techniques for measureing airflows in buildings. P Lagus, AK Persily | 92 | 1985 |
Input data for multizone airflow and IAQ analysis AK Persily, EM Ivy US Department of Commerce, Technology Administration, National Institute of …, 2001 | 91 | 2001 |
Ultrafine particle removal and ozone generation by in-duct electrostatic precipitators DG Poppendieck, D Rim, AK Persily Environmental science & technology 48 (3), 2067-2074, 2014 | 89 | 2014 |
Multizone airflow models for calculating infiltration rates in commercial reference buildings LC Ng, A Musser, AK Persily, SJ Emmerich Energy and Buildings 58, 11-18, 2013 | 83 | 2013 |