关注
Lois Holloway
Lois Holloway
Liverpool
在 health.nsw.gov.au 的电子邮件经过验证
标题
引用次数
引用次数
年份
A review of medical image data augmentation techniques for deep learning applications
P Chlap, H Min, N Vandenberg, J Dowling, L Holloway, A Haworth
Journal of Medical Imaging and Radiation Oncology 65 (5), 545-563, 2021
5752021
Uncertainties in volume delineation in radiation oncology: a systematic review and recommendations for future studies
SK Vinod, MG Jameson, M Min, LC Holloway
Radiotherapy and Oncology 121 (2), 169-179, 2016
3182016
The potential for an enhanced role for MRI in radiation-therapy treatment planning
P Metcalfe, GP Liney, L Holloway, A Walker, M Barton, GP Delaney, ...
Technology in cancer research & treatment 12 (5), 429-446, 2013
2382013
Advances in kilovoltage x-ray beam dosimetry
R Hill, B Healy, L Holloway, Z Kuncic, D Thwaites, C Baldock
Physics in Medicine & Biology 59 (6), R183, 2014
2332014
The role of deep learning and radiomic feature extraction in cancer-specific predictive modelling: a review
A Vial, D Stirling, M Field, M Ros, C Ritz, M Carolan, L Holloway, AA Miller
Translational Cancer Research 7 (3), 2018
2132018
A review of interventions to reduce inter‐observer variability in volume delineation in radiation oncology
SK Vinod, M Min, MG Jameson, LC Holloway
Journal of medical imaging and radiation oncology 60 (3), 393-406, 2016
1942016
A review of methods of analysis in contouring studies for radiation oncology
MG Jameson, LC Holloway, PJ Vial, SK Vinod, PE Metcalfe
Journal of medical imaging and radiation oncology 54 (5), 401-410, 2010
1742010
MRI distortion: considerations for MRI based radiotherapy treatment planning
A Walker, G Liney, P Metcalfe, L Holloway
Australasian physical & engineering sciences in medicine 37, 103-113, 2014
1612014
A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
R Hill, L Holloway, C Baldock
Physics in Medicine & Biology 50 (21), N331, 2005
1022005
Treatment plan comparison using equivalent uniform biologically effective dose (EUBED)
LC Jones, PW Hoban
Physics in Medicine & Biology 45 (1), 159, 2000
942000
How important is dosimetrist experience for intensity modulated radiation therapy? A comparative analysis of a head and neck case
V Batumalai, MG Jameson, DF Forstner, P Vial, LC Holloway
Practical radiation oncology 3 (3), e99-e106, 2013
902013
The use of the linear quadratic model in radiotherapy: a review
L Jones, P Hoban, P Metcalfe
Australasian Physics & Engineering Sciences in Medicine 24, 132-146, 2001
892001
A review of segmentation and deformable registration methods applied to adaptive cervical cancer radiation therapy treatment planning
S Ghose, L Holloway, K Lim, P Chan, J Veera, SK Vinod, G Liney, ...
Artificial intelligence in medicine 64 (2), 75-87, 2015
712015
The integration of MRI in radiation therapy: collaboration of radiographers and radiation therapists
R Rai, S Kumar, V Batumalai, D Elwadia, L Ohanessian, E Juresic, ...
Journal of Medical Radiation Sciences 64 (1), 61-68, 2017
662017
experimental results from a prototype high‐field inline MRI‐linac
GP Liney, B Dong, J Begg, P Vial, K Zhang, F Lee, A Walker, R Rai, ...
Medical physics 43 (9), 5188-5194, 2016
652016
Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom
A Walker, G Liney, L Holloway, J Dowling, D Rivest‐Henault, P Metcalfe
Medical physics 42 (4), 1982-1991, 2015
632015
Machine learning applications in radiation oncology
M Field, N Hardcastle, M Jameson, N Aherne, L Holloway
Physics and Imaging in Radiation oncology 19, 13-24, 2021
612021
Rapid learning in practice: a lung cancer survival decision support system in routine patient care data
A Dekker, S Vinod, L Holloway, C Oberije, A George, G Goozee, ...
Radiotherapy and Oncology 113 (1), 47-53, 2014
612014
Deep learning for segmentation in radiation therapy planning: a review
G Samarasinghe, M Jameson, S Vinod, M Field, J Dowling, A Sowmya, ...
Journal of Medical Imaging and Radiation Oncology 65 (5), 578-595, 2021
602021
Multicenter evaluation of MRI‐based radiomic features: A phantom study
R Rai, LC Holloway, C Brink, M Field, RL Christiansen, Y Sun, MB Barton, ...
Medical physics 47 (7), 3054-3063, 2020
602020
系统目前无法执行此操作,请稍后再试。
文章 1–20