Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) analysis of hemodynamics in valve-sparing aortic root repair with an anatomically shaped … TH Oechtering, CF Hons, M Sieren, P Hunold, A Hennemuth, ... The Journal of thoracic and cardiovascular surgery 152 (2), 418-427. e1, 2016 | 60 | 2016 |
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update MM Bissell, F Raimondi, LA Ali, BD Allen, AJ Barker, A Bolger, N Burris, ... Journal of Cardiovascular Magnetic Resonance 25 (1), 40, 2023 | 53 | 2023 |
Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) reveals altered blood flow patterns in the ascending aorta of patients with valve-sparing … TH Oechtering, MM Sieren, P Hunold, A Hennemuth, M Huellebrand, ... The Journal of thoracic and cardiovascular surgery 159 (3), 798-810. e1, 2020 | 36 | 2020 |
Comparison of 4D Flow MRI to 2D Flow MRI in the pulmonary arteries in healthy volunteers and patients with pulmonary hypertension MM Sieren, C Berlin, TH Oechtering, P Hunold, D Drömann, ... PLoS One 14 (10), e0224121, 2019 | 31 | 2019 |
Automated segmentation and quantification of the healthy and diseased aorta in CT angiographies using a dedicated deep learning approach MM Sieren, C Widmann, N Weiss, JH Moltz, F Link, F Wegner, ... European radiology 32 (1), 690-701, 2022 | 22 | 2022 |
Malrotated sinus vortices in straight graft valve-sparing aortic root treatment: a matter of concern? TH Oechtering, A Frydrychowicz, HH Sievers The Journal of Thoracic and Cardiovascular Surgery 154 (3), 794-797, 2017 | 22 | 2017 |
Work and Training Conditions of German Residents in Radiology–Results from a Nationwide Survey Conducted by the Young Radiology Forum in the German Roentgen Society TH Oechtering, N Panagiotopoulos, M Völker, S Lohwasser, S Ellmann, ... RöFo-Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden …, 2020 | 18 | 2020 |
Clinical applications of 4D flow MRI in the portal venous system TH Oechtering, GS Roberts, N Panagiotopoulos, O Wieben, SB Reeder, ... Magnetic Resonance in Medical Sciences 21 (2), 340-353, 2022 | 15 | 2022 |
Repeatability and reproducibility of various 4D Flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study TH Oechtering, A Nowak, MM Sieren, AM Stroth, N Kirschke, F Wegner, ... Journal of Cardiovascular Magnetic Resonance 25 (1), 22, 2023 | 11 | 2023 |
Abdominal applications of quantitative 4D flow MRI TH Oechtering, GS Roberts, N Panagiotopoulos, O Wieben, ... Abdominal Radiology, 1-22, 2022 | 11 | 2022 |
Magnetic particle imaging: in vitro signal analysis and lumen quantification of 21 endovascular stents F Wegner, A von Gladiss, J Haegele, U Grzyska, MM Sieren, E Stahlberg, ... International Journal of Nanomedicine, 213-221, 2021 | 11 | 2021 |
Die Arbeits-und Weiterbildungssituation junger Ärztinnen und Ärzte in Deutschland–eine zusammenfassende Analyse von Befragungsergebnissen aus sechs Fachrichtungen SC Joachim, D Bitzinger, H Arnold, J Lermann, TH Oechtering, S Schott, ... Das Gesundheitswesen 82 (03), 227-235, 2020 | 11 | 2020 |
In vitro 4D flow MRI evaluation of aortic valve replacements reveals disturbed flow distal to biological but not to mechanical valves TH Oechtering, M Sieren, K Schubert, T Schaller, M Scharfschwerdt, ... Journal of Cardiac Surgery 34 (12), 1452-1457, 2019 | 11 | 2019 |
Work and training of young doctors in Germany-a comprehensive analysis of survey results from six disciplines SC Joachim, D Bitzinger, H Arnold, J Lermann, TH Oechtering, S Schott, ... Gesundheitswesen (Bundesverband der Arzte des Offentlichen …, 2019 | 11 | 2019 |
Endovascular stent-based revascularization of malignant superior vena cava syndrome with concomitant implantation of a port device using a dual venous approach S Anton, T Oechtering, E Stahlberg, F Jacob, M Kleemann, J Barkhausen, ... Supportive Care in Cancer 26, 1881-1888, 2018 | 10 | 2018 |
Automated MR image prescription of the liver using deep learning: Development, evaluation, and prospective implementation R Geng, CJ Buelo, M Sundaresan, J Starekova, N Panagiotopoulos, ... Journal of Magnetic Resonance Imaging 58 (2), 429-441, 2023 | 9 | 2023 |
4D flow CMR analysis comparing patients with anatomically shaped aortic sinus prostheses, tube prostheses and healthy subjects introducing the wall shear stress gradient: a … MM Sieren, V Schultz, B Fujita, F Wegner, M Huellebrand, ... Journal of Cardiovascular Magnetic Resonance 22 (1), 59, 2020 | 9 | 2020 |
Vision, development, and structure of the first German specialist training curriculum for radiology I Molwitz, A Frisch, G Adam, S Afat, J Ammon, G Antoch, B Baeßler, ... RöFo-Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden …, 2022 | 8 | 2022 |
Work expectations, their fulfillment, and exhaustion among radiologists of all career levels: what can be learned from the example of Germany I Molwitz, C Kemper, K Stahlmann, TH Oechtering, MM Sieren, S Afat, ... European Radiology 33 (8), 5664-5674, 2023 | 7 | 2023 |
Heating of an aortic stent for coarctation treatment during magnetic particle imaging and magnetic resonance imaging—a comparative in vitro study U Grzyska, T Friedrich, MM Sieren, E Stahlberg, TH Oechtering, ... CardioVascular and Interventional Radiology 44, 1109-1115, 2021 | 7 | 2021 |