关注
Michele Lionello
Michele Lionello
Department of Information Engineering, University of Padova
在 studenti.unipd.it 的电子邮件经过验证
标题
引用次数
引用次数
年份
Modelling and control of a free cooling system for data centers
A Beghi, L Cecchinato, G Dalla Mana, M Lionello, M Rampazzo, E Sisti
Energy Procedia 140, 447-457, 2017
322017
A static moving boundary modelling approach for simulation of indirect evaporative free cooling systems
M Rampazzo, M Lionello, A Beghi, E Sisti, L Cecchinato
Applied Energy 250, 1719-1728, 2019
272019
Graph-based modelling and simulation of liquid immersion cooling systems
M Lionello, M Rampazzo, A Beghi, D Varagnolo, M Vesterlund
Energy 207, 118238, 2020
242020
Energy-efficient operation of an indirect adiabatic cooling system for data centers
A Beghi, G Dalla Mana, M Lionello, M Rampazzo, E Sisti
2017 American Control Conference (ACC), 1984-1989, 2017
82017
Energy‐efficient operation of indirect adiabatic data center cooling systems via Newton‐like phasor extremum seeking control
M Lionello, R Lucchese, M Rampazzo, M Guay, K Atta
International Journal of Adaptive Control and Signal Processing 35 (7), 1298 …, 2021
72021
Efficient operation of indirect evaporative data center cooling systems via newton-like extremum-seeking control
A Beghi, M Lionello, M Rampazzo
2019 IEEE Conference on Control Technology and Applications (CCTA), 424-429, 2019
72019
Data-driven supervisory control of indirect adiabatic cooling systems
A Beghi, G Dalla Mana, M Lionello, M Rampazzo
2018 IEEE Conference on Control Technology and Applications (CCTA), 1203-1208, 2018
62018
Newton-like phasor extremum seeking control with application to cooling data centers
R Lucchese, M Lionello, M Rampazzo, M Guay, K Atta
IFAC-PapersOnLine 52 (16), 813-818, 2019
52019
Automation of the peripheral resistance valve in a hydro-mechanical cardiovascular pulse duplicator system
M Rampazzo, E Manzoni, M Lionello, L Di Micco, FM Susin
Control Engineering Practice 116, 104929, 2021
42021
Model-free Control of Data Center Compressor-based Cooling Systems
M Rampazzo, M Lionello, FC Panebianco, A Beghi
2018 IEEE 4th International Forum on Research and Technology for Society and …, 2018
42018
On economic cooling of contained server racks using an indirect adiabatic air handler
R Lucchese, M Lionello, M Rampazzo, A Johansson, W Birk
2020 36th Semiconductor Thermal Measurement, Modeling & Management Symposium …, 2020
32020
Real-time efficient operation of decatizing processes via a geometric-based extremum seeking control
FF Ferro, M Lionello, M Rampazzo, A Beghi, M Guay
IFAC-PapersOnLine 53 (2), 1614-1620, 2020
32020
Modelling and simulation of a convective low temperature sludge dryer with multilayer belt
A Beghit, P Franceschetti, M Rampazzo, E Sisti, CA Algarvia, M Lionello
Research and Technologies for Society and Industry (RTSI), 2017 IEEE 3rd …, 2017
22017
Energy-efficient management of a wood industry facility
A Beghi, M Lionello, M Rampazzo
2017 IEEE Conference on Control Technology and Applications (CCTA), 181-186, 2017
22017
Lumped-parameters Control-oriented Gray-box Modelling of Liquid Immersion Cooling Systems
M Lionello, M Rampazzo, A Beghi, D Varagnolo, M Vesterlund
2019 18th European Control Conference (ECC), 3861-3866, 2019
2019
Data-driven anomaly detection in HVAC chillers
A Beghi, M Lionello, M Rampazzo, F Simmini, F Peterle
51st Aicarr International Conference The Human Dimension Of Building Energy …, 2019
2019
Model-Free control of indirect evaporative cooling systems
A Beghi, M Lionello, M Rampazzo
51st Aicarr International Conference The Human Dimension Of Building Energy …, 2019
2019
Gradient-free optimization of data center cooling using Extremum Seeking
R Lucchese, M Lionello, M Rampazzo, M Guay, K Atta
22nd Nordic Process Control Workshop (NPCW22), Kgs. Lyngby, Denmark, August …, 2019
2019
Progettazione e simulazione di un sistema di" cruise control" in ambiente Matlab/Simulink
M Lionello
Reformatted version of paper submitted to
R Lucchese, M Lionello, M Rampazzo, A Johansson
Cooling Control Strategies in Data Centers for Energy Efficiency and Heat …, 0
系统目前无法执行此操作,请稍后再试。
文章 1–20