关注
Riza Bayoglu
Riza Bayoglu
Sr. Research Engineer at NuVasive
在 nuvasive.com 的电子邮件经过验证
标题
引用次数
引用次数
年份
Twente Spine Model: A thorough investigation of the spinal loads in a complete and coherent musculoskeletal model of the human spine
R Bayoglu, PE Galibarov, N Verdonschot, B Koopman, J Homminga
Medical engineering & physics 68, 35-45, 2019
412019
Twente spine model: a complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine
R Bayoglu, L Geeraedts, KHJ Groenen, N Verdonschot, B Koopman, ...
Journal of biomechanics 58, 52-63, 2017
332017
Implementation of boundary conditions in modeling the femur is critical for the evaluation of distal intramedullary nailing
R Bayoglu, AF Okyar
Medical engineering & physics 37 (11), 1053-1060, 2015
272015
Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the lumbar region of the human spine
R Bayoglu, L Geeraedts, KHJ Groenen, N Verdonschot, B Koopman, ...
Journal of biomechanics 53, 111-119, 2017
182017
Validation and sensitivity of model-predicted proximal tibial displacement and tray micromotion in cementless total knee arthroplasty under physiological loading conditions
H Yang, R Bayoglu, MS Renani, Y Behnam, A Navacchia, C Clary, ...
Journal of the Mechanical Behavior of Biomedical Materials 109, 103793, 2020
132020
Sensitivity of muscle and intervertebral disc force computations to variations in muscle attachment sites
R Bayoglu, O Guldeniz, N Verdonschot, B Koopman, J Homminga
Computer methods in biomechanics and biomedical engineering 22 (14), 1135-1143, 2019
92019
Impact of patient, surgical, and implant design factors on predicted tray–bone interface micromotions in cementless total knee arthroplasty
H Yang, R Bayoglu, CW Clary, PJ Rullkoetter
Journal of Orthopaedic Research® 41 (1), 115-129, 2023
72023
The effect of loading in mechanical response predictions of bone lengthening
AF Okyar, R Bayoglu
Medical engineering & physics 34 (9), 1362-1367, 2012
72012
Impact of surgical alignment, tray material, PCL condition, and patient anatomy on tibial strains after TKA
H Yang, R Bayoglu, CW Clary, PJ Rullkoetter
Medical Engineering & Physics 88, 69-77, 2021
32021
A physiologically accurate mechanical representation of the bone-implant construct under gait loads
R Bayoglu, AF Okyar
Proceedings of the sixth national biomechanics congress, Sakarya University, 2012
32012
Clinical Validation of a Novel Musculoskeletal Modeling Framework to Predict Postoperative Sagittal Alignment
R Bayoglu, JP Witt, GP Chatain, DO Okonkwo, AS Kanter, DK Hamilton, ...
Spine 48 (8), E107-E115, 2023
22023
How valid are left-right symmetrical musculo-skeletal models?
R Bayoglu, L Geeraedts, K Groenen, NJJ Verdonschot, HFJM Koopman, ...
22nd Congress of the European Society of Biomechanics, ESB 2016, 2016
22016
Experimental Characterization of Impaction Energy During Hip Broaching: Comparison of Mallet and Powered Impaction
CC Riza Bayoglu, Luke Storer, Yashar Behnam, Dan Huff, J Bohannon Mason
2019
Twente Spine Model: Development, validation, and application of a complete and coherent musculoskeletal model of the human spine
R Bayoglu
2019
The Influence of Fusion Length on Surgical Correction of Spinopelvic Mismatch and Pelvic Tilt
GP Chatain, R Bayoglu, DO Okonkwo, AS Kanter, DK Hamilton, N Alan, ...
系统目前无法执行此操作,请稍后再试。
文章 1–15