Development and validation of a Radiance model for a translucent panel CF Reinhart, M Andersen Energy and buildings 38 (7), 890-904, 2006 | 296 | 2006 |
Daylighting Metrics: Is there a relation between Useful Daylight Illuminance and Daylight Glare Probabilty? J Mardaljevic, M Andersen, N Roy, J Christoffersen Proceedings of Building Simulation and Optimization conference BSO12, 2012 | 254 | 2012 |
Adequacy of immersive virtual reality for the perception of daylit spaces: comparison of real and virtual environments K Chamilothori, J Wienold, M Andersen Leukos, 2018 | 235 | 2018 |
A framework for predicting the non-visual effects of daylight–Part I: photobiology-based model M Andersen, J Mardaljevic, SW Lockley Lighting research & technology 44 (1), 37-53, 2012 | 220 | 2012 |
Influence of shading control patterns on the energy assessment of office spaces PC Da Silva, V Leal, M Andersen Energy and Buildings 50, 35-48, 2012 | 153 | 2012 |
Daylighting metrics for residential buildings J Mardaljevic, M Andersen, N Roy, J Christoffersen Proceedings of the 27th Session of the CIE, 2011 | 153 | 2011 |
Occupants interaction with electric lighting and shading systems in real single-occupied offices: Results from a monitoring campaign PC da Silva, V Leal, M Andersen Building and Environment 64, 152-168, 2013 | 151 | 2013 |
Approved method: IES spatial Daylight autonomy (sDA) and annual sunlight exposure (ASE) I Lm Illum Eng Soc https//www ies org/product/ies-spatial-daylight-autonomy-sda …, 2013 | 151 | 2013 |
Cross-validation and robustness of daylight glare metrics J Wienold, T Iwata, M Sarey Khanie, E Erell, E Kaftan, RG Rodriguez, ... Lighting Research & Technology 51 (7), 983-1013, 2019 | 145 | 2019 |
Preliminary Method for Prospective Analysis of the Circadian Efficacy of (Day)Light with Applications to Healthcare Architecture CS Pechacek, M Andersen, SW Lockley LEUKOS 5 (1), 1-26, 2008 | 145 | 2008 |
A human-centric approach to assess daylight in buildings for non-visual health potential, visual interest and gaze behavior ML Amundadottir, S Rockcastle, MS Khanie, M Andersen Building and Environment 113, 5-21, 2017 | 137 | 2017 |
Subjective and physiological responses to façade and sunlight pattern geometry in virtual reality K Chamilothori, G Chinazzo, J Rodrigues, ES Dan-Glauser, J Wienold, ... Building and Environment 150, 144-155, 2019 | 133 | 2019 |
An intuitive daylighting performance analysis and optimization approach M Andersen, S Kleindienst, L Yi, J Lee, M Bodart, B Cutler Building Research & Information 36 (6), 593-607, 2008 | 130 | 2008 |
Unweaving the human response in daylighting design M Andersen Building and Environment 91, 101-117, 2015 | 122 | 2015 |
Experimental validation of simulation methods for bi-directional transmission properties at the daylighting performance level F Maamari, M Andersen, J de Boer, WL Carroll, D Dumortier, P Greenup Energy and Buildings 38 (7), 878-889, 2006 | 111 | 2006 |
Goniophotometry and assessment of bidirectional photometric properties of complex fenestration systems M Andersen, J De Boer Energy and buildings 38 (7), 836-848, 2006 | 108 | 2006 |
Bi-directional transmission properties of Venetian blinds: experimental assessment compared to ray-tracing calculations M Andersen, M Rubin, R Powles, JL Scartezzini Solar Energy 78 (2), 187-198, 2005 | 108 | 2005 |
Daylight affects human thermal perception G Chinazzo, J Wienold, M Andersen Scientific reports 9 (1), 13690, 2019 | 107 | 2019 |
Graphical representation of climate-based daylight performance to support architectural design S Kleindienst, M Bodart, M Andersen LEUKOS 5 (1), 39-61, 2008 | 103 | 2008 |
Comparing daylighting performance assessment of buildings in scale models and test modules A Thanachareonkit, JL Scartezzini, M Andersen Solar Energy 79 (2), 168-182, 2005 | 99 | 2005 |