New developments in bone-conduction hearing implants: a review S Reinfeldt, B Håkansson, H Taghavi, M Eeg-Olofsson Medical Devices: Evidence and Research, 79-93, 2015 | 276 | 2015 |
A novel bone conduction implant (BCI): engineering aspects and pre-clinical studies B Håkansson, S Reinfeldt, M Eeg-Olofsson, P Östli, H Taghavi, J Adler, ... International journal of audiology 49 (3), 203-215, 2010 | 111 | 2010 |
Transmission of bone conducted sound–correlation between hearing perception and cochlear vibration M Eeg-Olofsson, S Stenfelt, H Taghavi, S Reinfeldt, B Håkansson, ... Hearing Research 306, 11-20, 2013 | 97 | 2013 |
The bone conduction implant: Clinical results of the first six patients S Reinfeldt, B Håkansson, H Taghavi, KJ Fredén Jansson, ... International Journal of Audiology 54 (6), 408-416, 2015 | 54 | 2015 |
The bone conduction implant—first implantation, surgical and audiologic aspects M Eeg-Olofsson, B Håkansson, S Reinfeldt, H Taghavi, H Lund, ... Otology & Neurotology 35 (4), 679-685, 2014 | 49 | 2014 |
Bone conduction hearing sensitivity in normal-hearing subjects: transcutaneous stimulation at BAHA vs BCI position S Reinfeldt, B Håkansson, H Taghavi, M Eeg-Olofsson International journal of Audiology 53 (6), 360-369, 2014 | 48 | 2014 |
Analysis and design of RF power and data link using amplitude modulation of class-E for a novel bone conduction implant H Taghavi, B Hkansson, S Reinfeldt IEEE transactions on biomedical engineering 59 (11), 3050-3059, 2012 | 41 | 2012 |
Technical design of a new bone conduction implant (BCI) system H Taghavi, B Håkansson, S Reinfeldt, M Eeg-Olofsson, KJF Jansson, ... International journal of audiology 54 (10), 736-744, 2015 | 33 | 2015 |
MRI induced torque and demagnetization in retention magnets for a bone conduction implant KJF Jansson, B Håkansson, S Reinfeldt, H Taghavi, M Eeg-Olofsson IEEE transactions on biomedical engineering 61 (6), 1887-1893, 2014 | 26 | 2014 |
Feedback analysis in percutaneous bone-conduction device and bone-conduction implant on a dry cranium H Taghavi, B Håkansson, S Reinfeldt, M Eeg-Olofsson, S Akhshijan Otology & neurotology 33 (3), 413-420, 2012 | 24 | 2012 |
Study of the feasible size of a bone conduction implant transducer in the temporal bone S Reinfeldt, P Östli, B Håkansson, H Taghavi, M Eeg-Olofsson, J Stalfors Otology & Neurotology 36 (4), 631-637, 2015 | 22 | 2015 |
A novel bone conduction implant-analog radio frequency data and power link design H Taghavi, B Håkansson, S Reinfeldt 9th IASTED International Conference on Biomedical Engineering, BioMed 2012 …, 2012 | 18 | 2012 |
An earbud-type wearable (A hearable) with vital parameter sensors for early detection and prevention of heat-stroke K Matsumoto, Y Temiz, H Taghavi, EL Cornelius, H Mori, B Michel 2019 41st Annual International Conference of the IEEE Engineering in …, 2019 | 16 | 2019 |
Optimal position of a new bone conduction implant M Eeg-Olofsson, S Stenfelt, B Håkansson, H Taghavi, S Reinfeldt, P Östli, ... Cochlear implants international 12 (sup1), S136-S138, 2011 | 12 | 2011 |
A vibration investigation of a flat surface contact to skull bone for direct bone conduction transmission in sheep skulls in vivo H Taghavi, B Håkansson, M Eeg-Olofsson, CB Johansson, A Tjellström, ... Otology & Neurotology 34 (4), 690-698, 2013 | 11 | 2013 |
Balanced armature receiver with bi-stable balanced armature AZ Van Halteren, PC Van Hal, H Taghavi, A Tiefenau, W Bruins US Patent 10,582,303, 2020 | 8 | 2020 |
Evaluation of Bone Tissue Formation in a Flat Surface Attachment of a Bone Conduction Implant: A Pilot Study in a Sheep Model M Eeg-Olofsson, A Lith, B Håkansson, S Reinfeldt, H Taghavi, ... Audiology and Neurotology Extra 4 (3), 62-76, 2014 | 4 | 2014 |
The Bone Conduction Implant (BCI)-Preclinical Studies, Technical Design and a Clinical Evaluation H Taghavi PQDT-Global, 2014 | 4 | 2014 |
A novel bone conduction implant system H Taghavi PQDT-Global, 2012 | 4 | 2012 |
Augmented hearing device MK Andersen, H Taghavi US Patent 10,433,077, 2019 | 3 | 2019 |