Fire safety investigation for road tunnel ventilation systems–an overview L Barbato, F Cascetta, M Musto, G Rotondo Tunnelling and Underground Space Technology 43, 253-265, 2014 | 93 | 2014 |
Numerical study of the optimization of the pitch angle of an alternative jet fan in a longitudinal tunnel ventilation system V Betta, F Cascetta, M Musto, G Rotondo Tunnelling and underground space technology 24 (2), 164-172, 2009 | 81 | 2009 |
Fluid dynamic performances of traditional and alternative jet fans in tunnel longitudinal ventilation systems V Betta, F Cascetta, M Musto, G Rotondo Tunnelling and Underground Space Technology 25 (4), 415-422, 2010 | 77 | 2010 |
Numerical comparison of performance between traditional and alternative jet fans in tiled tunnel in emergency ventilation M Musto, G Rotondo Tunnelling and Underground Space Technology 42, 52-58, 2014 | 48 | 2014 |
A simplified methodology to simulate a heat exchanger in an aircraft's oil cooler by means of a Porous Media model M Musto, N Bianco, G Rotondo, F Toscano, G Pezzella Applied thermal engineering 94, 836-845, 2016 | 46 | 2016 |
CFD analysis of a realistic reduced-scale modeling equipped with axial jet fan M Musto, G Rotondo Fire Safety Journal 74, 11-24, 2015 | 34 | 2015 |
Measuring of compressed natural gas in automotive application: A comparative analysis of mass versus volumetric metering methods F Cascetta, G Rotondo, M Musto Flow Measurement and Instrumentation 19 (6), 338-341, 2008 | 34 | 2008 |
Numerical analysis for reduced-scale road tunnel model equipped with axial jet fan ventilation system A Costantino, M Musto, G Rotondo, A Zullo Energy Procedia 45, 1146-1154, 2014 | 33 | 2014 |
Innovative experimental reduced scale model of road tunnel equipped with realistic longitudinal ventilation system F Cascetta, M Musto, G Rotondo Tunnelling and underground space technology 52, 85-98, 2016 | 31 | 2016 |
Effects of intermittent flows on turbine gas meters accuracy F Cascetta, G Rotondo Measurement 69, 280-286, 2015 | 17 | 2015 |
Adiabatic surface temperature as thermal/structural parameter in fire modeling: thermal analysis for different wall conductivities A Andreozzi, N Bianco, M Musto, G Rotondo Applied thermal engineering 65 (1-2), 422-432, 2014 | 16 | 2014 |
The influence of the filling percentage traffic on required ventilation thrust in road tunnel F Cascetta, M Musto, G Rotondo, L Barbato International Journal of Heat and Technology 34 (October 2016), 451-457, 2016 | 12 | 2016 |
An experimental intercomparison of gas meter calibrations F Cascetta, M Comazzi, M Musto, G Rotondo Measurement 45 (8), 1951-1959, 2012 | 11 | 2012 |
Influence of wall emissivity and convective heat transfer coefficient on the adiabatic surface temperature as thermal/structural parameter in fire modeling A Andreozzi, N Bianco, M Rotondo, Giuseppe, Marilena Applied Thermal Engineering, 2012 | 7 | 2012 |
Quasi-steady state numerical model for a multilayer thin film irradiated by a moving laser source at high Peclet numbers N Bianco, O Manca, V Naso, G Rotondo ASME International Mechanical Engineering Congress and Exposition 37181, 177-186, 2003 | 5 | 2003 |
The role of methane hydrates in the failure of a gas pipeline F Caputo, F Cascetta, G Lamanna, G Rotondo, A Soprano Key Engineering Materials 577, 377-380, 2014 | 4 | 2014 |
Ventilation: Types, Standards, and Problems VA Romano, AS Duval Nova Science Publishers, 2011 | 1* | 2011 |
Numerical analysis of a confined fire Andreozzi, Bianco, Musto, Naso, Rotondo 31st UIT Heat Transfer Conference, 385-394, 2012 | | 2012 |
Metrological compatibility of four diaphragm gas meter calibrations F.Cascetta, G. Cignolo, M. Comazzi, M. Musto, G asme-ati-uit conference on thermal and environmental issues in energy systems, 2010 | | 2010 |
IMECE2003-41919 Quasi-Steady State Numerical Model for a Multilayer Thin Film Irradiated by a Moving Laser Source at High Peclet Numbers N Bianco, O Manca, V Naso, G Rotondo ASME-PUBLICATIONS-HTD 374 (3), 177-186, 2003 | | 2003 |