Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance‐frequency analysis study with sandblasted‐and‐etched ITI implants M Bischof, R Nedir, S Szmukler‐Moncler, JP Bernard, J Samson Clinical oral implants research 15 (5), 529-539, 2004 | 602 | 2004 |
Predicting osseointegration by means of implant primary stability: A resonance‐frequency analysis study with delayed and immediately loaded ITI SLA implants R Nedir, M Bischof, S Szmukler‐Moncler, JP Bernard, J Samson Clinical oral implants research 15 (5), 520-528, 2004 | 593 | 2004 |
A 7‐year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants: Results from a private practice R Nedir, M Bischof, JM Briaux, S Beyer, S Szmukler‐Moncler, JP Bernard Clinical Oral Implants Research 15 (2), 150-157, 2004 | 370 | 2004 |
Osteotome sinus floor elevation without grafting material: a 1‐year prospective pilot study with ITI implants R Nedir, M Bischof, L Vazquez, S Szmukler‐Moncler, JP Bernard Clinical oral implants research 17 (6), 679-686, 2006 | 259 | 2006 |
Enhanced implant stability with a chemically modified SLA surface: a randomized pilot study TW Oates, P Valderrama, M Bischof, R Nedir, A Jones, J Simpson, ... International Journal of Oral and Maxillofacial Implants 22 (5), 755, 2007 | 236 | 2007 |
Prosthetic complications with ITI dental implants. Results from an up to 8-year experience in private practice. R Nedir Department of Stomatology and Oral Surgery, School of Dental Medicine …, 1800 | 182 | 1800 |
Osteotome sinus floor elevation technique without grafting material: 3‐year results of a prospective pilot study R Nedir, M Bischof, L Vazquez, N Nurdin, S Szmukler‐Moncler, ... Clinical Oral Implants Research 20 (7), 701-707, 2009 | 158 | 2009 |
Osteotome sinus floor elevation with and without grafting material in the severely atrophic maxilla. A 1‐year prospective randomized controlled study R Nedir, N Nurdin, P Khoury, T Perneger, ME Hage, JP Bernard, ... Clinical oral implants research 24 (11), 1257-1264, 2013 | 143 | 2013 |
Esthetic outcomes with porcelain‐fused‐to‐ceramic and all‐ceramic single‐implant crowns: a randomized clinical trial GO Gallucci, L Grütter, R Nedir, M Bischof, UC Belser Clinical Oral Implants Research 22 (1), 62-69, 2011 | 119 | 2011 |
Osteotome sinus floor elevation technique without grafting: a 5‐year prospective study R Nedir, N Nurdin, L Vazquez, S Szmukler‐Moncler, M Bischof, ... Journal of clinical periodontology 37 (11), 1023-1028, 2010 | 114 | 2010 |
Osteotome sinus floor elevation without grafting: A 10‐year prospective study R Nedir, N Nurdin, L Vazquez, S Abi Najm, M Bischof Clinical Implant Dentistry and Related Research 18 (3), 609-617, 2016 | 112 | 2016 |
Short implants placed with or without grafting into atrophic sinuses: the 5‐year results of a prospective randomized controlled study R Nedir, N Nurdin, S Abi Najm, M El Hage, M Bischof Clinical oral implants research 28 (7), 877-886, 2017 | 110 | 2017 |
Placement of tapered implants using an osteotome sinus floor elevation technique without bone grafting: 1-year results. R Nedir, N Nurdin, S Szmukler-Moncler, M Bischof Int. J Oral Maxillofacial Implants, 2009: 24: 727 733, 1800 | 102 | 1800 |
Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects L Vazquez, Y Nizamaldin, C Combescure, R Nedir, M Bischof, ... Dentomaxillofacial Radiology 42 (2), 20110429, 2013 | 97 | 2013 |
A five‐year life‐table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice M Bischof, R Nedir, S Abi Najm, S Szmukler‐Moncler, J Samson Clinical oral implants research 17 (5), 512-520, 2006 | 89 | 2006 |
Short implants placed with or without grafting in atrophic sinuses: the 3‐year results of a prospective randomized controlled study R Nedir, N Nurdin, P Khoury, M Bischof Clinical implant dentistry and related research 18 (1), 10-18, 2016 | 87 | 2016 |
Titanium hydride and hydrogen concentration in acid‐etched commercially pure titanium and titanium alloy implants: a comparative analysis of five implant systems S Szmukler‐Moncler, M Bischof, R Nedir, M Ermrich Clinical oral implants research 21 (9), 944-950, 2010 | 74 | 2010 |
Peripheral giant cell granuloma associated with a dental implant M Bischof, R Nedir, T Lombardi International Journal of Oral and Maxillofacial Implants 19 (2), 295-302, 2004 | 57 | 2004 |
Osteotome sinus floor elevation technique without grafting material and immediate implant placement in atrophic posterior maxilla: report of 2 cases R Nedir, N Nurdin, S Szmukler-Moncler, M Bischof Journal of Oral and Maxillofacial Surgery 67 (5), 1098-1103, 2009 | 40 | 2009 |
Periapical central giant cell granuloma misdiagnosed as odontogenic cyst T Lombardi, M Bischof, R Nedir, D Vergain, C Galgano, J Samson, ... International endodontic journal 39 (6), 510-515, 2006 | 36 | 2006 |