Intracoronal Mandibular Kennedy Class I Implant-Tooth-Supported Removable Partial Overdenture: A 2-Year Multicenter Prospective Study. NH El-Mekawy, S El-Negoly, M Grawish, Y El-Hawary International Journal of Oral & Maxillofacial Implants 27 (3), 2012 | 26 | 2012 |
Impact of implants number and attachment type on the peri-implant stresses and retention of palateless implant-retained overdenture SA Hegazy, N El Mekawy, RMK Emera Indian Journal of Dental Research 31 (3), 414, 2020 | 16 | 2020 |
Peri-implant Outcomes with Laser vs Nanosurface Treatment of Early Loaded Implant-Retaining Mandibular Overdentures. S Hegazy, N El Mekawy, RMK Emera The International journal of oral & maxillofacial implants 31 (2), 424-30, 2016 | 15* | 2016 |
The Influence of Palatal Coverage on the Retention Force and Fatigue Resistance of Mini Dental Implant Maxillary Overdenture N El Mekawy, A Khalifa, E Abdualgabbar J Oral Hyg Health 4 (200), 2332-0702.10002, 2016 | 14 | 2016 |
RETENTIVE FORCE AND SURFACE ROUGHNESS OF PARTIAL REMOVABLE FRAMEWORKS FABRICATED FROM CONVENTIONAL CHROME-COBALT AND CAD / CAM MODIFIED POLY-ETHER-ETHERKETONE MATERIALS (WITHIN … N El Mekawy, ES Gad Egyptian Dental Journal 62 (3), 5055 - 5062, 2016 | 9 | 2016 |
Comparison of three different forms of denture adhesives: direct measurement of denture retention and, study of patient satisfaction N El Mekawy, A Habib, A Gomaa Egyptian Dental Journal 58, 1, 2012 | 9* | 2012 |
Scanning Electron Microscopy Observations of Osseointegration Failures of Dental Implants that Support Mandibular Overdentures N El-Mekawy, MM Fouad, YM El-Hawary, MA Al-Shahat, R El-Gendy Implant dentistry 22 (6), 645-649, 2013 | 8 | 2013 |
Effect of Implant Position and Edentulous Span Length on Stresses Around Implants Assisting Claspless Distal Extension Partial Overdentures: An In Vitro Study. MA ELsyad, AAEG Kabil, N El Mekawy Journal of Oral Implantology 43 (2), 100-106, 2017 | 7 | 2017 |
Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant‑retained overdentures N El Mekawy, MY Elhawary Journal of clinical and experimental dentistry 11 (1), e33, 2019 | 6 | 2019 |
Updates from 2018: Being indexed in Embase, becoming an affiliated journal of the World Federation for Medical Education, implementing an optional open data policy, adopting … S Huh Journal of Educational Evaluation for Health Professions 15, 2018 | 6 | 2018 |
Digital Versus Conventional Design For Mandibular Distal Extension RPD: A Study of Passivity of RPD Components and Principal Abutment Alveolar Bone Height Changes NE El-Khamisy, AH Habib, NE El-Mekawy, RM Emera Mansoura Journal of Dentistry 4 (14), 6-13, 2017 | 6 | 2017 |
Mandibular kennedy class i partial denture management by broad stress distribution philosophy (radiographic assessment) MM Abd El-Khalik, NH El Mekawy, SS El-Kasaby The Journal of the Indian Prosthodontic Society 16 (3), 282, 2016 | 6 | 2016 |
Bite Force and Bone HeigHt cHanges around aButments retaining mandiBular removaBle Partial denture witH wrougHt wire and Polyamide clasPs: sPlit moutH study AK Khalifa, N Elmekawy Egyptian Dental Journal 65 (1-January (Fixed Prosthodontics, Dental …, 2019 | 5 | 2019 |
Stress Releasing Clasp Assemblies Design Related To Abutment Alveolar Bone Resorption MA El-Khalek, MAS Aldeen, N EI-makawee Egyptian Dental Journal 52 (3), 1785, 2006 | 5* | 2006 |
Influence of Various Polishing Protocols on Polyether-Ether-Ketone Removable Partial Frameworks Fabricated By CAD / CAM (Scanning Electron Microscope Study) R Attayeb, M Elgamal, NA El-Wassefy, N El-Mekawy IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) 18, 34-39, 2019 | 4 | 2019 |
In Vitro Comparison of Denture Cleansers Effect on Locator Attachment Retentive Male Inserts (Scanning Electron Microscope Study) N El Mekawy, MI Algraisi, NH El Shaheed ORAL HEALTH AND DENTAL MANAGEMENT 17 (5), 2018 | 4 | 2018 |
IMPACT OF VARIOUS IMPRESSION TECHNIQUES ON MAXILLARY FLABBY RIDGE TISSUE DISPLACEMENT (WITHIN-SUBJECT EVALUATION) A Gomaa, N El Mekawy Egyptian Dental Journal 63 (3), 1161-1169, 2017 | 4 | 2017 |
The Implant stability and bone height changes for immediately loaded single implant-retained mandibular overdentures with locator attachments EA Abdel-Khalek, N El Mekawy International Dental Research 8 (3), 96-104, 2018 | 3 | 2018 |
Impact of Denture Base Materials on Retention of Tooth Retained and Supported Mandibular Overdenture N El Mekawy, S Hegazy, C Raouf Periodontics and Prosthodontics. 1 (1), 4, 2015 | 3 | 2015 |
Fitness evaluation of mandibular kennedy class I BioHPP Poly-Ether-Ether ketone removable partial denture fabricated by various techniques KAA Shaban, F Mahanna, N El Mekawy IP Ann Prosthodont Restor Dent 5 (4), 97-103, 2019 | 2 | 2019 |