Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis AC Godest, M Beaugonin, E Haug, M Taylor, PJ Gregson Journal of biomechanics 35 (2), 267-275, 2002 | 542 | 2002 |
Stress and strain distribution within the intact femur: compression or bending? ME Taylor, KE Tanner, MAR Freeman, AL Yettram Medical engineering & physics 18 (2), 122-131, 1996 | 366 | 1996 |
Computational modelling of cell spreading and tissue regeneration in porous scaffolds BG Sengers, M Taylor, CP Please, ROC Oreffo Biomaterials 28 (10), 1926-1940, 2007 | 202 | 2007 |
Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading LA Knight, S Pal, JC Coleman, F Bronson, H Haider, DL Levine, M Taylor, ... Journal of biomechanics 40 (7), 1550-1558, 2007 | 188 | 2007 |
Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? M Taylor, PJ Prendergast Journal of biomechanics 48 (5), 767-778, 2015 | 184 | 2015 |
Statistical modelling of the whole human femur incorporating geometric and material properties R Bryan, P Surya Mohan, A Hopkins, F Galloway, M Taylor, PB Nair Medical engineering & physics 32 (1), 57-65, 2010 | 173 | 2010 |
Fatigue failure of cancellous bone: a possible cause of implant migration and loosening M Taylor, KE Tanner Journal of Bone and Joint Surgery-British Volume 79 (2), 181, 1997 | 173 | 1997 |
Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk R Bryan, PB Nair, M Taylor Journal of Biomechanics 42 (13), 2171-2176, 2009 | 150 | 2009 |
Influence of head constraint and muscle forces on the strain distribution within the intact femur JA Simoes, MA Vaz, S Blatcher, M Taylor Medical Engineering & Physics 22 (7), 453-459, 2000 | 149 | 2000 |
Finite element analysis of a total ankle replacement during the stance phase of gait B Reggiani, A Leardini, F Corazza, M Taylor Journal of biomechanics 39 (8), 1435-1443, 2006 | 140 | 2006 |
Finite element analysis of the implanted proximal tibia:: a relationship between the initial cancellous bone stresses and implant migration M Taylor, KE Tanner, MAR Freeman Journal of biomechanics 31 (4), 303-310, 1998 | 131 | 1998 |
Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis IAJ Radcliffe, M Taylor Clinical Biomechanics 22 (7), 780-786, 2007 | 126 | 2007 |
Three-dimensional finite element modelling of the human ACL: simulation of passive knee flexion with a stressed and stress-free ACL G Limbert, M Taylor, J Middleton Journal of biomechanics 37 (11), 1723-1731, 2004 | 124 | 2004 |
Biomechanical changes and recovery of gait function after total hip arthroplasty for osteoarthritis: a systematic review and meta-analysis JS Bahl, MJ Nelson, M Taylor, LB Solomon, JB Arnold, D Thewlis Osteoarthritis and cartilage 26 (7), 847-863, 2018 | 123 | 2018 |
Finite element analysis of unicompartmental knee arthroplasty AR Hopkins, AM New, F Rodriguez-y-Baena, M Taylor Medical engineering & physics 32 (1), 14-21, 2010 | 115 | 2010 |
Cancellous bone stresses surrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis M Taylor, KE Tanner, MAR Freeman, AL Yettram Medical engineering & physics 17 (7), 544-550, 1995 | 115 | 1995 |
Cement mantle fatigue failure in total hip replacement: experimental and computational testing JRT Jeffers, M Browne, AB Lennon, PJ Prendergast, M Taylor Journal of biomechanics 40 (7), 1525-1533, 2007 | 109 | 2007 |
Bone remodelling inside a cemented resurfaced femoral head S Gupta, AMR New, M Taylor Clinical Biomechanics 21 (6), 594-602, 2006 | 106 | 2006 |
Verification of predicted knee replacement kinematics during simulated gait in the Kansas knee simulator JP Halloran, CW Clary, LP Maletsky, M Taylor, AJ Petrella, PJ Rullkoetter Journal of biomechanical engineering 132, 081010, 2010 | 101 | 2010 |
Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis IAJ Radcliffe, M Taylor Clinical Biomechanics 22 (4), 422-430, 2007 | 95 | 2007 |