Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the Hamburg Sequential Ablation Strategy RR Tilz, A Rillig, AM Thum, A Arya, P Wohlmuth, A Metzner, S Mathew, ... Journal of the American College of Cardiology 60 (19), 1921-1929, 2012 | 563 | 2012 |
Multicenter outcomes for catheter ablation of idiopathic premature ventricular complexes R Latchamsetty, M Yokokawa, F Morady, HM Kim, S Mathew, R Tilz, ... JACC: Clinical Electrophysiology 1 (3), 116-123, 2015 | 339 | 2015 |
One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon A Metzner, B Reissmann, P Rausch, S Mathew, P Wohlmuth, R Tilz, ... Circulation: Arrhythmia and Electrophysiology 7 (2), 288-292, 2014 | 265 | 2014 |
Unexpectedly high incidence of stroke and left atrial appendage thrombus formation after electrical isolation of the left atrial appendage for the treatment of atrial … A Rillig, RR Tilz, T Lin, T Fink, CH Heeger, A Arya, A Metzner, S Mathew, ... Circulation: Arrhythmia and Electrophysiology 9 (5), e003461, 2016 | 196 | 2016 |
Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon A Metzner, A Burchard, P Wohlmuth, P Rausch, A Bardyszewski, ... Circulation: Arrhythmia and Electrophysiology 6 (4), 769-775, 2013 | 176 | 2013 |
Stand-alone pulmonary vein isolation versus pulmonary vein isolation with additional substrate modification as index ablation procedures in patients with persistent and long … T Fink, M Schlüter, CH Heeger, C Lemes, T Maurer, B Reissmann, J Riedl, ... Circulation: Arrhythmia and Electrophysiology 10 (7), e005114, 2017 | 175 | 2017 |
The incidence of phrenic nerve injury during pulmonary vein isolation using the second‐generation 28 mm cryoballoon A Metzner, P Rausch, C Lemes, B Reissmann, A Bardyszewski, R Tilz, ... Journal of cardiovascular electrophysiology 25 (5), 466-470, 2014 | 142 | 2014 |
Once isolated, always isolated? Incidence and characteristics of pulmonary vein reconduction after second-generation cryoballoon-based pulmonary vein isolation CH Heeger, E Wissner, S Mathew, S Deiss, C Lemes, A Rillig, ... Circulation: Arrhythmia and Electrophysiology 8 (5), 1088-1094, 2015 | 117 | 2015 |
One-year clinical success of a ‘no-bonus’ freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation E Wissner, CH Heeger, H Grahn, B Reissmann, P Wohlmuth, C Lemes, ... EP Europace 17 (8), 1236-1240, 2015 | 109 | 2015 |
Ventricular arrhythmias arising from the left ventricular outflow tract below the aortic sinus cusps: mapping and catheter ablation via transseptal approach and … F Ouyang, S Mathew, S Wu, M Kamioka, A Metzner, Y Xue, W Ju, B Yang, ... Circulation: Arrhythmia and Electrophysiology 7 (3), 445-455, 2014 | 106 | 2014 |
Cryoballoon temperature predicts acute pulmonary vein isolation A Fürnkranz, I Köster, KRJ Chun, A Metzner, S Mathew, M Konstantinidou, ... Heart rhythm 8 (6), 821-825, 2011 | 106 | 2011 |
One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: a retrospective analysis C Lemes, E Wissner, T Lin, S Mathew, S Deiss, A Rillig, C Heeger, ... EP Europace 18 (2), 201-205, 2016 | 105 | 2016 |
Predictive value of programmed ventricular stimulation after catheter ablation of post-infarction ventricular tachycardia M Yokokawa, HM Kim, K Baser, W Stevenson, K Nagashima, ... Journal of the American College of Cardiology 65 (18), 1954-1959, 2015 | 99 | 2015 |
Ablation of atrial fibrillation in patients≥ 75 years: long-term clinical outcome and safety I Metzner, E Wissner, RR Tilz, A Rillig, S Mathew, B Schmidt, J Chun, ... Europace 18 (4), 543-549, 2016 | 89 | 2016 |
Ten-year clinical outcome after circumferential pulmonary vein isolation utilizing the Hamburg approach in patients with symptomatic drug-refractory paroxysmal atrial fibrillation RR Tilz, CH Heeger, A Wick, AM Saguner, A Metzner, A Rillig, ... Circulation: Arrhythmia and Electrophysiology 11 (2), e005250, 2018 | 82 | 2018 |
Electrical isolation of a substrate after myocardial infarction: a novel ablation strategy for unmappable ventricular tachycardias—feasibility and clinical outcome RR Tilz, H Makimoto, T Lin, A Rillig, S Deiss, E Wissner, S Mathew, ... Europace 16 (7), 1040-1052, 2014 | 78 | 2014 |
Acute efficacy, safety, and long-term clinical outcomes using the second-generation cryoballoon for pulmonary vein isolation in patients with a left common pulmonary vein: a … CH Heeger, V Tscholl, E Wissner, T Fink, L Rottner, P Wohlmuth, ... Heart Rhythm 14 (8), 1111-1118, 2017 | 75 | 2017 |
Short tip–big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon CH Heeger, E Wissner, S Mathew, K Hayashi, C Sohns, B Reißmann, ... Clinical research in cardiology 105, 482-488, 2016 | 72 | 2016 |
One-year clinical outcome after pulmonary vein isolation using the novel endoscopic ablation system in patients with paroxysmal atrial fibrillation A Metzner, B Schmidt, A Fuernkranz, E Wissner, RR Tilz, KRJ Chun, ... Heart Rhythm 8 (7), 988-993, 2011 | 69 | 2011 |
Bonus-freeze: benefit or risk? Two-year outcome and procedural comparison of a “bonus-freeze” and “no bonus-freeze” protocol using the second-generation cryoballoon for … CH Heeger, E Wissner, P Wohlmuth, S Mathew, K Hayashi, C Sohns, ... Clinical research in cardiology 105, 774-782, 2016 | 68 | 2016 |