关注
Martin Angerer
Martin Angerer
Postdoctoral Fellow at the University of British Columbia
在 ubc.ca 的电子邮件经过验证
标题
引用次数
引用次数
年份
Semi-automated packaging of transducer arrays for 3D ultrasound computer tomography
M Angerer, M Zapf, B Leyrer, NV Ruiter
2020 IEEE SENSORS, 1-4, 2020
72020
Model-guided manufacturing of transducer arrays based on single-fibre piezocomposites
M Angerer, M Zapf, B Leyrer, NV Ruiter
Applied Sciences 10 (14), 4927, 2020
72020
Single-Fiber Transducer Arrays for 3-D Ultrasound Computed Tomography: From Requirements to Results
M Angerer, M Zapf, SE Gebhardt, H Neubert, NV Ruiter
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 70 …, 2023
62023
Transducer arrays for 3D ultrasound computed tomography
M Angerer
62022
Enhanced KLM model for single-fibre piezocomposite transducers
M Angerer, M Zapf, S Gebhardt, H Neubert, NV Ruiter
2020 IEEE International Ultrasonics Symposium (IUS), 1-4, 2020
62020
Single-PZT-fiber transducers for 3D ultrasound computed tomography: Characterization and modeling
M Angerer, M Zapf, S Gebhardt, NV Ruiter
2022 IEEE International Ultrasonics Symposium (IUS), 1-4, 2022
52022
Realization of an pseudo-randomly sampled 3D USCT
M Zapf, T Hopp, H Gemmeke, M Angerer, Z Lu, O Molchanova, ...
Medical Imaging 2022: Ultrasonic Imaging and Tomography 12038, 43-47, 2022
52022
Static and dynamic forces in the incudostapedial joint gap
M Koch, TM Eßinger, M Angerer, T Stoppe, M Bornitz, M Neudert, ...
Hearing Research 378, 92-100, 2019
52019
Exploring the potentials of polymer-based cmuts for 3d ultrasound computed tomography
M Angerer, J Welsch, CD Gerardo, NV Ruiter, E Cretu, R Rohling
2023 IEEE International Ultrasonics Symposium (IUS), 1-4, 2023
42023
Method to extract frequency dependent material attenuation for improved transducer models
M Angerer, M Zapf, J Koppenhofer, NV Ruiter
2021 IEEE International Ultrasonics Symposium (IUS), 1-4, 2021
42021
Studying the Effects of Mutual Acoustic Impedance on the Performance of Polymer-Based CMUTs
M Angerer, J Welsch, CD Gerardo, NV Ruiter, E Cretu, R Rohling
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 2024
32024
Quality control of ultrasound transducers using distribution-free overlapping coefficients
M Angerer, M Zapf, M Koch, NV Ruiter
2021 IEEE Sensors, 1-4, 2021
22021
Active common‐mode filter for capacitive‐coupled isolated signalling
M Angerer, R Schwanninger, M März
Electronics Letters 56 (2), 73-76, 2020
12020
Aktiver Filter zur Filterung von Gleichtaktstörungen
R Schwanninger, M Angerer, M März
12019
Accurately Predicting the Performance of Polymer-Based CMUTs by Coupling Finite-Element and Analytical Models
M Angerer, J Welsch, CD Gerardo, E Cretu, R Rohling
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 2025
2025
First US Performance Measurements of Next Generation 3D USCT 2.5 Transducers
M Zapf, M Angerer, K Hohlfeld, S Gebhardt, H Gemmeke, NV Ruiter
Proceedings of the International Workshop on Medical Ultrasound Tomography …, 2021
2021
Multi-tap bus communication for modular power converters with distributed isolation
M Angerer, A Amler, B Ruccius, M Maerz
PCIM Europe 2019; International Exhibition and Conference for Power …, 2019
2019
Construction and Optimization of a Bidirectional Transducer to Treat Hearing Loss
M Angerer, M Koch, A Hellmuth, S Pieper, M Bornitz
Student Conference Medical Engineering Science 2014: Proceedings 3, 107, 2014
2014