Pre-earthquake and post-earthquake retrofitting of poorly detailed exterior RC beam-to-column joints GI Kalogeropoulos, ADG Tsonos, D Konstandinidis, S Tsetines Engineering Structures 109, 1-15, 2016 | 62 | 2016 |
Effectiveness of the novel rehabilitation method of seismically damaged RC joints using C-FRP ropes and comparison with widely applied method using C-FRP sheets—Experimental … E Golias, AG Zapris, VK Kytinou, GI Kalogeropoulos, CE Chalioris, ... Sustainability 13 (11), 6454, 2021 | 49 | 2021 |
Effectiveness of R/C jacketing of substandard R/C columns with short lap splices GI Kalogeropoulos, AG Tsonos Structural monitoring and maintenance 1 (3), 273-292, 2014 | 24 | 2014 |
Influence of carbon fiber-reinforced ropes applied as external diagonal reinforcement on the shear deformation of RC joints C Karayannis, E Golias, GI Kalogeropoulos Fibers 10 (3), 28, 2022 | 21 | 2022 |
Seismic retrofitting of pre-1970 RC bridge columns using innovative jackets ADG Tsonos, GI Kalogeropoulos, PE Iakovidis, D Konstantinidis International Journal of Structural Engineering 8 (2), 133-147, 2017 | 19 | 2017 |
Seismic performance of RC beam–column joints designed according to older and modern codes: An attempt to reduce conventional reinforcement using steel fiber reinforced concrete AD Tsonos, G Kalogeropoulos, P Iakovidis, MZ Bezas, M Koumtzis Fibers 9 (7), 45, 2021 | 15 | 2021 |
Cyclic performance of RC columns with inadequate lap splices strengthened with CFRP jackets G Kalogeropoulos, AD Tsonos Fibers 8 (6), 39, 2020 | 14 | 2020 |
Earthquake-resistant rehabilitation of existing RC structures using high-strength steel fiber-reinforced concrete jackets GI Kalogeropoulos, ADG Tsonos, D Konstantinidis, PE Iakovidis Earthquakes and Structures 17 (1), 115-129, 2019 | 13 | 2019 |
Improvement of the cyclic response of RC columns with inadequate lap splices-Experimental and analytical investigation GI Kalogeropoulos, ADG Tsonos Earthquakes and Structures 16 (3), 279-293, 2019 | 13 | 2019 |
Seismic performance enhancement of RC columns using thin high-strength RC jackets and CFRP jackets G Kalogeropoulos, AD Tsonos Fibers 9 (5), 29, 2021 | 7 | 2021 |
Analytical model for the design of HSFC and UHSFC Jackets with various steel fiber volume fraction ratios for the retrofitting of RC beam-column joints AD Tsonos, G Kalogeropoulos Sustainability 13 (20), 11209, 2021 | 6 | 2021 |
Cyclic response of RC beam-column joints strengthened with transverse steel bars and with C-FRP diagonal ties E Golias, EA Vougioukas, K Wittemann, GI Kalogeropoulos, C Karayannis České vysoké učení technické v Praze, 2022 | 4 | 2022 |
Seismic behaviour of RC columns with welded rebars or mechanical splices of reinforcement GI Kalogeropoulos, ADG Tsonos, D Konstantinidis Earthquakes and Structures 17 (3), 297-306, 2019 | 3 | 2019 |
Hysteresis Behavior of RC Beam–Column Joints of Existing Substandard RC Structures Subjected to Seismic Loading–Experimental and Analytical Investigation G Kalogeropoulos, AD Tsonos, P Iakovidis Buildings 14 (6), 1609, 2024 | 1 | 2024 |
Effectiveness of the Novel Rehabilitation Method of Seismically Damaged RC Joints Using C-FRP Ropes and Comparison with Widely Applied Method Using C-FRP Sheets—Experimental … E Golias, A Zapris, V Kytinou, G Kalogeropoulos, C Chalioris, ... s Note: MDPI stays neutral with regard to jurisdictional claims in published …, 2021 | 1 | 2021 |