关注
Ronald Triolo
Ronald Triolo
Case Western Reserve University/US Department of Veterans Affairs
在 case.edu 的电子邮件经过验证
标题
引用次数
引用次数
年份
Functional electrical stimulation and spinal cord injury
CH Ho, RJ Triolo, AL Elias, KL Kilgore, AF DiMarco, K Bogie, AH Vette, ...
Physical Medicine and Rehabilitation Clinics 25 (3), 631-654, 2014
2662014
Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia
R Kobetic, RJ Triolo, EB Marsolais
IEEE Transactions on rehabilitation engineering 5 (1), 23-29, 1997
2581997
Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report
R Kobetic, RJ Triolo, JP Uhlir, C Bieri, M Wibowo, G Polando, ...
IEEE Transactions on Rehabilitation Engineering 7 (4), 390-398, 1999
2231999
Development of hybrid orthosis for standing, walking, and stair climbing after spinal cord injury.
R Kobetic, CS To, JR Schnellenberger, ML Audu, TC Bulea, R Gaudio, ...
Journal of Rehabilitation Research & Development 46 (3), 2009
2052009
A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis
MA Schiefer, RJ Triolo, DJ Tyler
IEEE transactions on neural systems and rehabilitation engineering 16 (2 …, 2008
1632008
Architecture of the rectus abdominis, quadratus lumborum, and erector spinae
SL Delp, S Suryanarayanan, WM Murray, J Uhlir, RJ Triolo
Journal of biomechanics 34 (3), 371-375, 2001
1512001
Clinical applications of electrical stimulation after spinal cord injury
GH Creasey, CH Ho, RJ Triolo, DR Gater, AF DiMarco, KM Bogie, ...
The journal of spinal cord medicine 27 (4), 365-375, 2004
1492004
New functional electrical stimulation approaches to standing and walking
VK Mushahwar, PL Jacobs, RA Normann, RJ Triolo, N Kleitman
Journal of neural engineering 4 (3), S181, 2007
1472007
Consumer perspectives on mobility: implications for neuroprosthesis design.
DL Brown-Triolo, MJ Roach, K Nelson, R Triolo
Journal of Rehabilitation Research & Development 39 (6), 2002
1462002
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
MA Schiefer, KH Polasek, RJ Triolo, GCJ Pinault, DJ Tyler
Journal of neural engineering 7 (2), 026006, 2010
1452010
Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand?
JA Davis Jr, RJ Triolo, J Uhlir, C Bieri, L Rohde, D Lissy, S Kukke
Journal of Rehabilitation Research & Development 38 (6), 2001
1332001
Experimental evaluation of an adaptive feedforward controller for use in functional neuromuscular stimulation systems
JJ Abbas, RJ Triolo
IEEE Transactions on Rehabilitation Engineering 5 (1), 12-22, 1997
1311997
Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes
KJ Gustafson, GCJ Pinault, JJ Neville, I Syed, JA Davis Jr, J Jean-Claude, ...
Journal of rehabilitation research and development 46 (7), 973, 2009
1292009
Walking after incomplete spinal cord injury using an implanted FES system: a case report.
E Hardin, R Kobetic, L Murray, M Corado-Ahmed, G Pinault, J Sakai, ...
Journal of Rehabilitation Research & Development 44 (3), 2007
1132007
Long-term user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury.
S Agarwal, RJ Triolo, R Kobetic, M Miller, C Bieri, S Kukke, L Rohde, ...
Journal of Rehabilitation Research & Development 40 (3), 2003
1092003
Effects of regular use of neuromuscular electrical stimulation on tissue health.
KM Bogie, RJ Triolo
Journal of Rehabilitation Research & Development 40 (6), 2003
1052003
High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations
H Charkhkar, CE Shell, PD Marasco, GJ Pinault, DJ Tyler, RJ Triolo
Journal of Neural Engineering 15 (5), 056002, 2018
992018
Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: clinical case reports
RJ Triolo, C Bieri, J Uhlir, R Kobetic, A Scheiner, EB Marsolais
Archives of physical medicine and rehabilitation 77 (11), 1119-1128, 1996
981996
Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves
BP Christie, M Freeberg, WD Memberg, GJC Pinault, HA Hoyen, DJ Tyler, ...
Journal of neuroengineering and rehabilitation 14, 1-12, 2017
962017
Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve
LE Fisher, DJ Tyler, JS Anderson, RJ Triolo
Journal of neural engineering 6 (4), 046010, 2009
942009
系统目前无法执行此操作,请稍后再试。
文章 1–20