Imaging time after Gd-DTPA injection is critical in using delayed enhancement to determine infarct size accurately with magnetic resonance imaging JN Oshinski, Z Yang, JR Jones, JF Mata, BA French Circulation 104 (23), 2838-2842, 2001 | 308 | 2001 |
Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129 JP Mugler III, TA Altes, IC Ruset, IM Dregely, JF Mata, GW Miller, S Ketel, ... Proceedings of the National Academy of Sciences 107 (50), 21707-21712, 2010 | 228 | 2010 |
Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon‐129 MRI K Qing, K Ruppert, Y Jiang, JF Mata, GW Miller, YM Shim, C Wang, ... Journal of magnetic resonance imaging 39 (2), 346-359, 2014 | 201 | 2014 |
Exploring lung function with hyperpolarized 129Xe nuclear magnetic resonance K Ruppert, JF Mata, JR Brookeman, KD Hagspiel, JP Mugler III Magnetic Resonance in Medicine: An Official Journal of the International …, 2004 | 162 | 2004 |
Assessment of lung function in asthma and COPD using hyperpolarized 129Xe chemical shift saturation recovery spectroscopy and dissolved‐phase MRI K Qing, JP Mugler III, TA Altes, Y Jiang, JF Mata, GW Miller, IC Ruset, ... NMR in biomedicine 27 (12), 1490-1501, 2014 | 126 | 2014 |
Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry JF Mata, TA Altes, J Cai, K Ruppert, W Mitzner, KD Hagspiel, B Patel, ... Journal of applied physiology 102 (3), 1273-1280, 2007 | 120 | 2007 |
Hyperpolarized xenon‐129 gas‐exchange imaging of lung microstructure: first case studies in subjects with obstructive lung disease I Dregely, JP Mugler III, IC Ruset, TA Altes, JF Mata, GW Miller, J Ketel, ... Journal of magnetic resonance imaging 33 (5), 1052-1062, 2011 | 115 | 2011 |
Assessment of lung development using hyperpolarized helium‐3 diffusion MR imaging TA Altes, J Mata, EE de Lange, JR Brookeman, JP Mugler III Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2006 | 109 | 2006 |
Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales: Comparison with healthy subjects and … C Wang, TA Altes, JP Mugler III, GW Miller, K Ruppert, JF Mata, ... Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2008 | 92 | 2008 |
Convolutional neural networks with template-based data augmentation for functional lung image quantification NJ Tustison, BB Avants, Z Lin, X Feng, N Cullen, JF Mata, L Flors, JC Gee, ... Academic radiology 26 (3), 412-423, 2019 | 70 | 2019 |
Protocols for multi‐site trials using hyperpolarized 129Xe MRI for imaging of ventilation, alveolar‐airspace size, and gas exchange: a position paper from the 129Xe MRI … PJ Niedbalski, CS Hall, M Castro, RL Eddy, JH Rayment, S Svenningsen, ... Magnetic resonance in medicine 86 (6), 2966-2986, 2021 | 58 | 2021 |
Multiple‐exchange‐time xenon polarization transfer contrast (MXTC) MRI: initial results in animals and healthy volunteers I Dregely, IC Ruset, JF Mata, J Ketel, S Ketel, J Distelbrink, TA Altes, ... Magnetic resonance in medicine 67 (4), 943-953, 2012 | 57 | 2012 |
A short‐breath‐hold technique for lung pO2 mapping with 3He MRI GW Miller, JP Mugler III, TA Altes, J Cai, JF Mata, EE De Lange, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2010 | 52 | 2010 |
MR grid‐tagging using hyperpolarized helium‐3 for regional quantitative assessment of pulmonary biomechanics and ventilation J Cai, TA Altes, GW Miller, K Sheng, PW Read, JF Mata, X Zhong, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2007 | 51 | 2007 |
Hyperpolarized helium-3 magnetic resonance lung imaging of non-sedated infants and young children: a proof-of-concept study TA Altes, CH Meyer, JF Mata, DK Froh, A Paget-Brown, WG Teague, ... Clinical imaging 45, 105-110, 2017 | 39 | 2017 |
Detecting pulmonary capillary blood pulsations using hyperpolarized xenon‐129 chemical shift saturation recovery (CSSR) MR spectroscopy K Ruppert, TA Altes, JF Mata, IC Ruset, FW Hersman, JP Mugler III Magnetic resonance in medicine 75 (4), 1771-1780, 2016 | 39 | 2016 |
In vivo performance of a microfabricated catheter for intraparenchymal delivery ML Brady, R Raghavan, D Singh, PJ Anand, AS Fleisher, J Mata, ... Journal of neuroscience methods 229, 76-83, 2014 | 34 | 2014 |
XTC MRI: sensitivity improvement through parameter optimization K Ruppert, JF Mata, HTJ Wang, WA Tobias, GD Cates, JR Brookeman, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2007 | 34 | 2007 |
q‐space analysis of lung morphometry in vivo with hyperpolarized 3He spectroscopy DD Shanbhag, TA Altes, GW Miller, JF Mata, J Knight‐Scott Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2006 | 30 | 2006 |
Emphysema Index Based on Hyperpolarized 3He or 129Xe Diffusion MRI: Performance and Comparison with Quantitative CT and … S Tafti, WJ Garrison, JP Mugler III, YM Shim, TA Altes, JF Mata, ... Radiology 297 (1), 201-210, 2020 | 27 | 2020 |