The use of radiography for thickness measurement and corrosion monitoring in pipes K Edalati, N Rastkhah, A Kermani, M Seiedi, A Movafeghi International journal of pressure vessels and piping 83 (10), 736-741, 2006 | 105 | 2006 |
An exhaustive criterion for estimating quality of images in electrical impedance tomography with application to clinical imaging A Javaherian, A Movafeghi, R Faghihi, E Yahaghi Journal of visual communication and image representation 24 (7), 773-785, 2013 | 30 | 2013 |
Defect detection of industrial radiography images of ammonia pipes by a sparse coding model A Movafeghi, N Mohammadzadeh, E Yahaghi, J Nekouei, P Rostami, ... Journal of Nondestructive Evaluation 37, 1-7, 2018 | 28 | 2018 |
Defect detection in thin plates by ultrasonic lamb wave techniques K Edalati, A Kermani, M Seiedi, A Movafeghi International Journal of Materials and Product Technology 27 (3-4), 156-172, 2006 | 28 | 2006 |
A novel method for predicting pixel value distribution non-uniformity due to heel effect of X-ray tube in industrial digital radiography using artificial neural network E Nazemi, A Movafeghi, B Rokrok, MHC Dastjerdi Journal of Nondestructive Evaluation 38, 1-10, 2019 | 20 | 2019 |
Reducing negative effects of quadratic norm regularization on image reconstruction in electrical impedance tomography A Javaherian, A Movafeghi, R Faghihi Applied Mathematical Modelling 37 (8), 5637-5652, 2013 | 18 | 2013 |
Estimation of volumetric water content during imbibition in porous building material using real time neutron radiography and artificial neural network E Nazemi, M Dinca, A Movafeghi, B Rokrok, MHC Dastjerdi Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2019 | 17 | 2019 |
Simulation of a complete X-ray digital radiographic system for industrial applications E Nazemi, B Rokrok, A Movafeghi, MHC Dastjerdi Applied Radiation and Isotopes 139, 294-303, 2018 | 17 | 2018 |
Flaw detection improvement of digitised radiographs by morphological transformations A Movafeghi, MH Kargarnovin, H Soltanian-Zadeh, M Taheri, F Ghasemi, ... Insight-Non-Destructive Testing and Condition Monitoring 47 (10), 625-630, 2005 | 16 | 2005 |
Industrial gamma computed tomography using high aspect ratio scintillator detectors (A Geant4 simulation) M Askari, A Taheri, A Movafeghi Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2019 | 15 | 2019 |
An accelerated version of alternating direction method of multipliers for TV minimization in EIT A Javaherian, M Soleimani, K Moeller, A Movafeghi, R Faghihi Applied Mathematical Modelling 40 (21-22), 8985-9000, 2016 | 15 | 2016 |
Contrast enhancement of industrial radiography images by gabor filtering with automatic noise thresholding E Yahaghi, A Movafeghi Russian Journal of Nondestructive Testing 55, 73-79, 2019 | 14 | 2019 |
Interlaced bilateral filtering and wavelet thresholding for flaw detection in the radiography of weldments E Yahaghi, M Mirzapour, A Movafeghi, B Rokrok The European Physical Journal Plus 135 (1), 42, 2020 | 13 | 2020 |
A gamma-ray tomography system to determine wax deposition distribution in oil pipelines M Askari, A Taheri, M Mojtahedzadeh Larijani, A Movafeghi, H Faripour Review of Scientific Instruments 90 (7), 2019 | 13 | 2019 |
Using empirical mode decomposition and a fuzzy algorithm for the analysis of weld defect images A Movafeghi Insight-Non-Destructive Testing and Condition Monitoring 57 (1), 35-39, 2015 | 13 | 2015 |
In-service corrosion evaluation in pipelines using gamma radiography–a numerical approach K Edalati, N Rastkhah, A Kermani, M Seiedi, A Movafeghi Insight-Non-Destructive Testing and Condition Monitoring 46 (7), 396-398, 2004 | 11 | 2004 |
FISTA algorithm for radiography images enhancement with background blurring removal E Yahaghi, M Mirzapour, A Movafeghi, P Mohammadi Matin, B Rokrok Research in Nondestructive Evaluation 30 (2), 80-88, 2019 | 10 | 2019 |
Automated defect detection of weldments and castings using Canny, Sobel and Gaussian filter edge detectors: A comparison study F Mirzaei, M Faridafshin, A Movafeghi, R Faghihi The proceedings of the 4th Iranian International NDT Conference, 2017 | 10 | 2017 |
Quality improvement of digitized radiographs by filtering technique development based on morphological transformations A Movafeghi, M Taheri, MH Kargarnovin, F Ghasemi, B Rokrok, M Seiedi, ... IEEE Symposium Conference Record Nuclear Science 2004. 3, 1845-1849, 2004 | 10 | 2004 |
A radiographic calibration method for eddy current testing of heat exchanger tubes A Movafeghi, MH Kargarnovin, H Soltanianzadeh, K Edalati, B Rokrok, ... Insight-Non-Destructive Testing and Condition Monitoring 46 (10), 594-597, 2004 | 10 | 2004 |