关注
Arpan Kumar Pradhan
Arpan Kumar Pradhan
Assistant Professor, Jadavpur University
在 jadavpuruniversity.in 的电子邮件经过验证
标题
引用次数
引用次数
年份
Diagnosis of power quality events based on detrended fluctuation analysis
S Das, AK Pradhan, A Kedia, S Dalai, B Chatterjee, S Chakravorti
IEEE Transactions on Industrial Electronics 65 (9), 7322-7331, 2018
522018
Estimation of paper moisture content based on dielectric dissipation factor of oil-paper insulation under non-sinusoidal excitations
AK Pradhan, B Chatterjee, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 22 (2), 822-830, 2015
412015
Effect of measurement temperature on power transformer insulation diagnosis using frequency‐domain spectroscopy
S Dutta, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 11 (6), 773-779, 2017
342017
Effect of temperature on frequency dependent dielectric parameters of oil-paper insulation under non-sinusoidal excitation
AK Pradhan, B Chatterjee, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 21 (2), 653-661, 2014
342014
Estimation of contamination level of overhead insulators based on surface leakage current employing detrended fluctuation analysis
S Deb, S Das, AK Pradhan, A Banik, B Chatterjee, S Dalai
IEEE Transactions on Industrial Electronics 67 (7), 5729-5736, 2019
312019
A method to estimate activation energy of power transformer insulation using time domain spectroscopy data
HC Verma, A Baral, AK Pradhan, S Chakravorti
IEEE transactions on Dielectrics and Electrical Insulation 24 (5), 3245-3253, 2017
312017
Investigation of dielectric properties of TiO2 and Al2O3 nanofluids by frequency domain spectroscopy at different temperatures
B Chakraborty, KY Raj, AK Pradhan, B Chatterjee, S Chakravorti, S Dalai
Journal of Molecular Liquids 330, 115642, 2021
282021
S-transform aided random forest based PD location detection employing signature of optical sensor
S Bag, AK Pradhan, S Das, S Dalai, B Chatterjee
IEEE Transactions on Power Delivery 34 (4), 1261-1268, 2018
232018
Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer
D Mishra, AK Pradhan, A Baral, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 25 (5), 1932-1940, 2018
212018
Reducing frequency domain spectroscopy measurement time for condition monitoring of transformer oil‐paper insulation using non‐sinusoidal excitations
S Chatterjee, AK Pradhan, S Dalai, B Chatterjee, S Chakravorti
IET Science, Measurement & Technology 11 (2), 204-212, 2017
202017
Determination of optimized slope of triangular excitation for condition assessment of oil-paper insulation by frequency domain spectroscopy
AK Pradhan, C Koley, B Chatterjee, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 23 (3), 1303-1312, 2016
202016
Estimation of conductivity at reduced time for sensing moisture content of oil-paper insulation
S Chatterjee, N Haque, AK Pradhan, S Dalai, B Chatterjee
IEEE Sensors Journal 20 (21), 12999-13006, 2020
192020
Estimation of moisture content in oil-impregnated pressboard through analyzing dielectric response current under switching impulse
AK Pradhan, S Tenbohlen
IEEE Transactions on Dielectrics and Electrical Insulation 28 (3), 938-945, 2021
182021
Condition monitoring of overhead polymeric insulators employing hyperbolic window stockwell transform of surface leakage current signals
K Sit, AK Das, D Mukherjee, N Haque, S Deb, AK Pradhan, S Dalai, ...
IEEE Sensors Journal 21 (9), 10957-10964, 2021
182021
Estimation of paper‐moisture in transformer insulation employing dielectric spectroscopy data
A Kumar, HC Verma, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 12 (4), 536-541, 2018
172018
Condition assessment of outdoor porcelain insulator based on dielectric dissipation factor evaluated from non‐linear equivalent circuit
AK Pradhan, S Chatterjee, A Banik, S Dalai, B Chatterjee
IET Science, Measurement & Technology 10 (8), 866-873, 2016
152016
Non-linear modeling of oil-paper insulation for condition assessment using non-sinusoidal excitation
A Pradhan, C Koley, B Chatterjee, S Chakravorti
IEEE Transactions on Dielectrics and Electrical Insulation 22 (4), 2165-2175, 2015
152015
Condition assessment of various regions within non‐uniformly aged cellulosic insulation of power transformer using modified Debye model
HC Verma, A Baral, AK Pradhan, S Chakravorti
IET Science, Measurement & Technology 11 (7), 939-947, 2017
142017
RPCNNet: A deep learning approach to sense minor stator winding interturn fault severity in induction motor under variable load condition
AK Das, S Das, AK Pradhan, B Chatterjee, S Dalai
IEEE Sensors Journal 23 (4), 3965-3972, 2023
132023
A review on characteristics and assessment techniques of high voltage silicone rubber insulator
K Sit, AK Pradhan, B Chatterjee, S Dalai
IEEE Transactions on Dielectrics and Electrical Insulation 29 (5), 1889-1903, 2022
132022
系统目前无法执行此操作,请稍后再试。
文章 1–20