Diagnosis of power quality events based on detrended fluctuation analysis S Das, AK Pradhan, A Kedia, S Dalai, B Chatterjee, S Chakravorti IEEE Transactions on Industrial Electronics 65 (9), 7322-7331, 2018 | 52 | 2018 |
Estimation of paper moisture content based on dielectric dissipation factor of oil-paper insulation under non-sinusoidal excitations AK Pradhan, B Chatterjee, S Chakravorti IEEE Transactions on Dielectrics and Electrical Insulation 22 (2), 822-830, 2015 | 41 | 2015 |
Effect of measurement temperature on power transformer insulation diagnosis using frequency‐domain spectroscopy S Dutta, A Baral, AK Pradhan, S Chakravorti IET Science, Measurement & Technology 11 (6), 773-779, 2017 | 34 | 2017 |
Effect of temperature on frequency dependent dielectric parameters of oil-paper insulation under non-sinusoidal excitation AK Pradhan, B Chatterjee, S Chakravorti IEEE Transactions on Dielectrics and Electrical Insulation 21 (2), 653-661, 2014 | 34 | 2014 |
Estimation of contamination level of overhead insulators based on surface leakage current employing detrended fluctuation analysis S Deb, S Das, AK Pradhan, A Banik, B Chatterjee, S Dalai IEEE Transactions on Industrial Electronics 67 (7), 5729-5736, 2019 | 31 | 2019 |
A method to estimate activation energy of power transformer insulation using time domain spectroscopy data HC Verma, A Baral, AK Pradhan, S Chakravorti IEEE transactions on Dielectrics and Electrical Insulation 24 (5), 3245-3253, 2017 | 31 | 2017 |
Investigation of dielectric properties of TiO2 and Al2O3 nanofluids by frequency domain spectroscopy at different temperatures B Chakraborty, KY Raj, AK Pradhan, B Chatterjee, S Chakravorti, S Dalai Journal of Molecular Liquids 330, 115642, 2021 | 28 | 2021 |
S-transform aided random forest based PD location detection employing signature of optical sensor S Bag, AK Pradhan, S Das, S Dalai, B Chatterjee IEEE Transactions on Power Delivery 34 (4), 1261-1268, 2018 | 23 | 2018 |
Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer D Mishra, AK Pradhan, A Baral, S Chakravorti IEEE Transactions on Dielectrics and Electrical Insulation 25 (5), 1932-1940, 2018 | 21 | 2018 |
Reducing frequency domain spectroscopy measurement time for condition monitoring of transformer oil‐paper insulation using non‐sinusoidal excitations S Chatterjee, AK Pradhan, S Dalai, B Chatterjee, S Chakravorti IET Science, Measurement & Technology 11 (2), 204-212, 2017 | 20 | 2017 |
Determination of optimized slope of triangular excitation for condition assessment of oil-paper insulation by frequency domain spectroscopy AK Pradhan, C Koley, B Chatterjee, S Chakravorti IEEE Transactions on Dielectrics and Electrical Insulation 23 (3), 1303-1312, 2016 | 20 | 2016 |
Estimation of conductivity at reduced time for sensing moisture content of oil-paper insulation S Chatterjee, N Haque, AK Pradhan, S Dalai, B Chatterjee IEEE Sensors Journal 20 (21), 12999-13006, 2020 | 19 | 2020 |
Estimation of moisture content in oil-impregnated pressboard through analyzing dielectric response current under switching impulse AK Pradhan, S Tenbohlen IEEE Transactions on Dielectrics and Electrical Insulation 28 (3), 938-945, 2021 | 18 | 2021 |
Condition monitoring of overhead polymeric insulators employing hyperbolic window stockwell transform of surface leakage current signals K Sit, AK Das, D Mukherjee, N Haque, S Deb, AK Pradhan, S Dalai, ... IEEE Sensors Journal 21 (9), 10957-10964, 2021 | 18 | 2021 |
Estimation of paper‐moisture in transformer insulation employing dielectric spectroscopy data A Kumar, HC Verma, A Baral, AK Pradhan, S Chakravorti IET Science, Measurement & Technology 12 (4), 536-541, 2018 | 17 | 2018 |
Condition assessment of outdoor porcelain insulator based on dielectric dissipation factor evaluated from non‐linear equivalent circuit AK Pradhan, S Chatterjee, A Banik, S Dalai, B Chatterjee IET Science, Measurement & Technology 10 (8), 866-873, 2016 | 15 | 2016 |
Non-linear modeling of oil-paper insulation for condition assessment using non-sinusoidal excitation A Pradhan, C Koley, B Chatterjee, S Chakravorti IEEE Transactions on Dielectrics and Electrical Insulation 22 (4), 2165-2175, 2015 | 15 | 2015 |
Condition assessment of various regions within non‐uniformly aged cellulosic insulation of power transformer using modified Debye model HC Verma, A Baral, AK Pradhan, S Chakravorti IET Science, Measurement & Technology 11 (7), 939-947, 2017 | 14 | 2017 |
RPCNNet: A deep learning approach to sense minor stator winding interturn fault severity in induction motor under variable load condition AK Das, S Das, AK Pradhan, B Chatterjee, S Dalai IEEE Sensors Journal 23 (4), 3965-3972, 2023 | 13 | 2023 |
A review on characteristics and assessment techniques of high voltage silicone rubber insulator K Sit, AK Pradhan, B Chatterjee, S Dalai IEEE Transactions on Dielectrics and Electrical Insulation 29 (5), 1889-1903, 2022 | 13 | 2022 |