Diffusion-weighted Imaging of the Liver with Multiple b Values: Effect of Diffusion Gradient Polarity and Breathing Acquisition on Image Quality and Intravoxel … HA Dyvorne, N Galea, T Nevers, MI Fiel, D Carpenter, E Wong, M Orton, ... Radiology 266 (3), 920-929, 2013 | 236 | 2013 |
Accelerated phase‐contrast cine MRI using k‐t SPARSE‐SENSE D Kim, HA Dyvorne, R Otazo, L Feng, DK Sodickson, VS Lee Magnetic resonance in medicine 67 (4), 1054-1064, 2012 | 161 | 2012 |
Variations of dynamic contrast-enhanced magnetic resonance imaging in evaluation of breast cancer therapy response: a multicenter data analysis challenge W Huang, X Li, Y Chen, X Li, MC Chang, MJ Oborski, DI Malyarenko, ... Translational oncology 7 (1), 153-166, 2014 | 158 | 2014 |
Hepatocellular carcinoma: short‐term reproducibility of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 T S Kakite, H Dyvorne, C Besa, N Cooper, M Facciuto, C Donnerhack, ... Journal of Magnetic Resonance Imaging 41 (1), 149-156, 2015 | 145 | 2015 |
Abdominal 4D flow MR imaging in a breath hold: combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition H Dyvorne, A Knight-Greenfield, G Jajamovich, C Besa, Y Cui, A Stalder, ... Radiology 275 (1), 245-254, 2015 | 109 | 2015 |
Electromagnetic shielding for magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,274,561, 2019 | 107 | 2019 |
Intravoxel incoherent motion diffusion imaging of the liver: optimal b-value subsampling and impact on parameter precision and reproducibility H Dyvorne, G Jajamovich, S Kakite, B Kuehn, B Taouli European journal of radiology 83 (12), 2109-2113, 2014 | 107 | 2014 |
Portable magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,222,434, 2019 | 104 | 2019 |
DCE‐MRI of the liver: effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibility S Aronhime, C Calcagno, GH Jajamovich, HA Dyvorne, P Robson, ... Journal of Magnetic Resonance Imaging 40 (1), 90-98, 2014 | 98 | 2014 |
Portable magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,539,637, 2020 | 96 | 2020 |
Deep learning techniques for magnetic resonance image reconstruction J Schlemper, SSM Salehi, M Sofka, P Kundu, Z Wang, C Lazarus, ... US Patent 11,467,239, 2022 | 93 | 2022 |
Low-field magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,520,566, 2019 | 91 | 2019 |
Low-field magnetic resonance imaging methods and apparatus HA Dyvorne, T Rearick, JM Rothberg, MS Poole US Patent 10,627,464, 2020 | 89 | 2020 |
Diffusion-weighted imaging of the liver: techniques and applications S Lewis, H Dyvorne, Y Cui, B Taouli Magnetic Resonance Imaging Clinics 22 (3), 373-395, 2014 | 89 | 2014 |
Quantitative liver MRI combining phase contrast imaging, elastography, and DWI: assessment of reproducibility and postprandial effect at 3.0 T GH Jajamovich, H Dyvorne, C Donnerhack, B Taouli PloS one 9 (5), e97355, 2014 | 86 | 2014 |
Electromagnetic shielding for magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,698,050, 2020 | 80 | 2020 |
Portable magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,444,310, 2019 | 79 | 2019 |
Low power magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,330,755, 2019 | 79 | 2019 |
Low-field magnetic resonance imaging methods and apparatus MS Poole, C Hugon, HA Dyvorne, L Sacolick, WJ Mileski, JC Jordan, ... US Patent 10,371,773, 2019 | 77 | 2019 |
Radio-frequency coil signal chain for a low-field MRI system HA Dyvorne, T Rearick US Patent 10,890,634, 2021 | 75 | 2021 |